Corneal profile analysis after Descemet stripping endothelial keratoplasty and its relationship to postoperative hyperopic shift.

Huck A Holz1, Jay J Meyer, Ladan Espandar, Geoffrey C Tabin, Mark D Mifflin, Majid Moshirfar.   

Abstract

PURPOSE: To evaluate changes in the corneal profile after Descemet stripping endothelial keratoplasty (DSEK) using anterior segment optical coherence tomography (AS-OCT) analysis and to describe its relationship to a dynamic postoperative hyperopic shift.
SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, USA.
METHODS: In this retrospective observational study, 9 eyes had DSEK and were followed with manifest refractions and AS-OCT analysis. To assess changes in the thickness of the cornea, measurements for each AS-OCT image were taken at the vertex of the cornea, at 1.5 mm on each side of the vertex, and at the distal edges of the graft.
RESULTS: Patients were followed for a mean of 134 days (range 46 to 228 days). Monthly Graft thinning rates were 5.2 microm per month at the vertex, 7.9 microm per month 1.5 mm from the vertex, and 26 microm per month at the edges, with the edges thinning significantly faster than the cornea vertex (P = .0024) and the points on either side of the 3.0 mm visual axis (P = .0018). The mean spherical equivalent (SE) showed an initial hyperopic shift that decreased over the ensuing 100 to 200 days postoperatively. The mean monthly postoperative SE change was -0.25 diopter (D) with a mean preoperative to postoperative SE change of +1.26 D.
CONCLUSIONS: The donor graft underwent changes after DSEK, which may account for the induced hyperopia and its diminishment over time via changes in the posterior corneal curvature. Results suggest that intraocular lenses be targeted to -1.00 to -1.25 D of myopia for combined DSEK and cataract procedures.

Entities:  

Mesh:

Year:  2008        PMID: 18242442     DOI: 10.1016/j.jcrs.2007.09.030

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  19 in total

1.  [Refractive changes after Descemet membrane endothelial keratoplasty].

Authors:  T Röck; K U Bartz-Schmidt; D Röck; E Yoeruek
Journal:  Ophthalmologe       Date:  2014       Impact factor: 1.059

2.  Analysis of posterior donor corneal parameters 1 year after Descemet stripping automated endothelial keratoplasty (DSAEK) triple procedure.

Authors:  Marco Lombardo; Mark A Terry; Giuseppe Lombardo; David D Boozer; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-01-29       Impact factor: 3.117

3.  Excimer laser smoothing of endothelial keratoplasty grafts.

Authors:  Catherine Cleary; Ying Liu; Maolong Tang; Yan Li; Christopher Stoeger; David Huang
Journal:  Cornea       Date:  2012-04       Impact factor: 2.651

4.  Evaluating DSAEK graft deturgescence in preservation medium after microkeratome cut with optical coherence tomography.

Authors:  Maolong Tang; Christopher Stoeger; Joshua Galloway; Jeffrey Holiman; Matthew R Bald; David Huang
Journal:  Cornea       Date:  2013-06       Impact factor: 2.651

5.  A comparison of posterior lamellar keratoplasty modalities: DLEK vs. DSEK.

Authors:  Chan-Hui Yi; Dong-Hoon Lee; Eui-Sang Chung; Tae-Young Chung
Journal:  Korean J Ophthalmol       Date:  2010-08-03

6.  Corneal back surface radius after DSEK and DSAEK: a comparative single surgeon case control study.

Authors:  Jan D Unterlauft; Katharina Elsässer; Wolfgang Haigis; Gerd Geerling
Journal:  Int Ophthalmol       Date:  2014-07-29       Impact factor: 2.031

7.  Double-pass microkeratome technique for ultra-thin graft preparation in Descemet's stripping automated endothelial keratoplasty.

Authors:  Maylon Hsu; Walter L Hereth; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2012-03-16

8.  Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty.

Authors:  Gavin S Tan; Mingguang He; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-07-23       Impact factor: 1.930

9.  Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty).

Authors:  Melissa H Y Wong; Annabel Chew; Hla M Htoon; Beng H Lee; Jun Cheng; Jiang Liu; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-08-01       Impact factor: 1.930

10.  Indications of optical coherence tomography in keratoplasties: literature review.

Authors:  Thiago Trindade Nesi; Daniel Amorim Leite; Fábio Medina Rocha; Marco Antônio Tanure; Pedro Paulo Reis; Eduardo Büchele Rodrigues; Mauro Silveira de Queiroz Campos
Journal:  J Ophthalmol       Date:  2012-10-15       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.