Literature DB >> 18329627

Intraocular pressure measurements following Descemet stripping endothelial keratoplasty.

Thasarat S Vajaranant1, Marianne O Price, Francis W Price, Jacob T Wilensky, Deepak P Edward.   

Abstract

PURPOSE: The effect of increased corneal thickness after Descemet stripping endothelial keratoplasty (DSEK) on intraocular pressure (IOP) measurement has not been previously studied. It is uncertain if this increase in corneal thickness would artificially elevate IOP reading by Goldmann tonometry [GAT] (Haag-Streit, Konig, Switzerland). Therefore the effect of DSEK-related thick cornea on IOP measurement was investigated using three different techniques.
DESIGN: Prospective cross-sectional study.
METHODS: Participants were recruited from a single tertiary referral center. Fifty eyes of 38 patients with successful DSEK at least three months prior to testing were evaluated. At the time of the study, none of the participants had clinically detectable corneal edema. IOP was measured with GAT, pneumatonometry, and dynamic contour tonometry (DCT) in an unmasked randomized sequence. Central corneal thickness (CCT) was measured by ultrasonic pachymetry.
RESULTS: Mean CCT was 701 +/- 68 microm. The mean IOP +/- standard deviation (SD) was 15.9 +/- 4.9 mm Hg for GAT, 20.3 +/- 4.5 mm Hg for pneumatonometry, and 19.8 +/- 4.4 mm Hg for DCT. Pneumatonometry and DCT IOP measurements were significant higher than GAT (P < .01). In contrast, the difference between pneumatonometry and DCT readings was not statistically significant (P = .28). The correlations between IOP and corneal thickness were not significant in this cohort (P > .05).
CONCLUSIONS: Falsely elevated GAT, as expected in thick corneas, was not demonstrated after DSEK. High IOP reading by GAT therefore should raise suspicion of elevated IOP in DSEK eyes.

Entities:  

Mesh:

Year:  2008        PMID: 18329627     DOI: 10.1016/j.ajo.2008.01.010

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  13 in total

1.  Intraocular pressure elevation after Descemet's stripping endothelial keratoplasty.

Authors:  Naoki Ozeki; Kenya Yuki; Daisuke Shiba; Shigeto Shimmura; Dogru Murat; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2012-05-30       Impact factor: 2.447

2.  Intraocular pressure after Descemet's stripping and non-Descemet's stripping automated endothelial keratoplasty.

Authors:  Yoshiro Mawatari; Akira Kobayashi; Hideaki Yokogawa; Kazuhisa Sugiyama
Journal:  Jpn J Ophthalmol       Date:  2011-03-13       Impact factor: 2.447

3.  Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty.

Authors:  M L Salvetat; M Zeppieri; F Miani; C Tosoni; L Parisi; P Brusini
Journal:  Eye (Lond)       Date:  2011-03-25       Impact factor: 3.775

4.  Intraocular pressure changes following Descemet's stripping with endothelial keratoplasty.

Authors:  Edgar M Espana; Zachary M Robertson; Bo Huang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-11-20       Impact factor: 3.117

Review 5.  Glaucoma management after corneal transplantation surgeries.

Authors:  Helen L Kornmann; Steven J Gedde
Journal:  Curr Opin Ophthalmol       Date:  2016-03       Impact factor: 3.761

6.  Glaucoma and corneal transplant procedures.

Authors:  Ammar M Al-Mahmood; Samar A Al-Swailem; Deepak P Edward
Journal:  J Ophthalmol       Date:  2012-01-18       Impact factor: 1.909

7.  Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

Authors:  Colin I Clement; Douglas G A Parker; Ivan Goldberg
Journal:  Open Ophthalmol J       Date:  2016-02-29

Review 8.  Descemet stripping automated endothelial keratoplasty.

Authors:  Namrata Sharma; Prafulla K Maharana; Shipra Singhi; Neelima Aron; Mukesh Patil
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

9.  De novo ocular hypertension after Descemet stripping endothelial keratoplasty: comparative 3-year incidence, risk factors, and outcomes.

Authors:  Errol W Chan; Tina T Wong; Hla M Htoon; Ching L Ho; Donald T Tan; Jodhbir S Mehta
Journal:  Clin Ophthalmol       Date:  2013-09-17

10.  Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty.

Authors:  Oded Ohana; David Varssano; Gabi Shemesh
Journal:  Indian J Ophthalmol       Date:  2017-07       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.