Multivariate model of refractive shift in Descemet-stripping automated endothelial keratoplasty.

William J Dupps1, Ying Qian, David M Meisler.   

Abstract

PURPOSE: To relate in situ graft shape in Descemet-stripping automated endothelial keratoplasty (DSAEK) to surgically induced refractive error.
SETTING: Academic eye institute.
METHODS: High frequency arc-scanning ultrasound was performed in 7 patients enrolled in a prospective study of microkeratome-assisted endothelial keratoplasty approved by the Investigative Review Board. A region of interest spanning the horizontal meridian was defined for analysis of epithelial, host, graft, and total corneal thicknesses. Graft thickness profiles were fit by quadratic polynomials where the 2nd-order coefficients represent the posterior corneal curvature contributed by the graft. The curvature coefficient and central graft thickness were analyzed as predictors of induced refractive error.
RESULTS: At final follow-up (mean 5.9 months +/- 3.2 [SD]), 3 patients had a hyperopic shift (+2.50 diopters [D] each), 3 had insignificant (< 0.50 D) refractive shifts, and 1 had a myopic shift. In the group with hyperopic shift, a negative lens effect was predicted by positive curvature coefficients, representing grafts that were thinner centrally than peripherally (mean +22.72 microm/mm(2); range +4.95 to +45.17 microm/mm(2)). In the group with minimal refractive shift, coefficients were less positive (mean +7.28 microm/mm(2); range +2.01 to +13.82 microm/mm(2)). The patient with a myopic shift (-1.00 D) had the only negative curvature coefficient (-0.64 microm/mm(2)). In a 2-predictor model of refractive shift, central graft thickness and the curvature coefficient together accounted for 86% of the variance in the refractive response to DSAEK (P = .025).
CONCLUSION: Nonuniform thickness profiles and variable central graft thicknesses both contribute to refractive shift after DSAEK.

Entities:  

Mesh:

Year:  2008        PMID: 18361978      PMCID: PMC2796246          DOI: 10.1016/j.jcrs.2007.11.045

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence.

Authors:  Francis W Price; Marianne O Price
Journal:  J Cataract Refract Surg       Date:  2006-03       Impact factor: 3.351

2.  Simple technique to unfold the donor corneal lenticule during Descemet's stripping and automated endothelial keratoplasty.

Authors:  Steven B Koenig; William J Dupps; Douglas J Covert; David M Meisler
Journal:  J Cataract Refract Surg       Date:  2007-02       Impact factor: 3.351

3.  New triple procedure: Descemet's stripping and automated endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation.

Authors:  Douglas J Covert; Steven B Koenig
Journal:  Ophthalmology       Date:  2007-04-12       Impact factor: 12.079

4.  Histology of dislocations in endothelial keratoplasty (DSEK and DLEK): a laboratory-based, surgical solution to dislocation in 100 consecutive DSEK cases.

Authors:  Mark A Terry; Karen L Hoar; Jennifer Wall; Paula Ousley
Journal:  Cornea       Date:  2006-09       Impact factor: 2.651

5.  Descemet-stripping automated endothelial keratoplasty.

Authors:  Mark S Gorovoy
Journal:  Cornea       Date:  2006-09       Impact factor: 2.651

6.  Early results of small-incision Descemet's stripping and automated endothelial keratoplasty.

Authors:  Steven B Koenig; Douglas J Covert
Journal:  Ophthalmology       Date:  2006-12-05       Impact factor: 12.079

7.  Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK).

Authors:  Steven B Koenig; Douglas J Covert; William J Dupps; David M Meisler
Journal:  Cornea       Date:  2007-07       Impact factor: 2.651

8.  Arc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis.

Authors:  D Z Reinstein; R H Silverman; T Raevsky; G J Simoni; H O Lloyd; D J Najafi; M J Rondeau; D J Coleman
Journal:  J Refract Surg       Date:  2000 Jul-Aug       Impact factor: 3.573

9.  Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant.

Authors:  Francis W Price; Marianne O Price
Journal:  J Refract Surg       Date:  2005 Jul-Aug       Impact factor: 3.573

  9 in total
  18 in total

1.  [Refractive changes after Descemet membrane endothelial keratoplasty].

Authors:  T Röck; K U Bartz-Schmidt; D Röck; E Yoeruek
Journal:  Ophthalmologe       Date:  2014       Impact factor: 1.059

2.  Endothelial keratoplasty: is Descemet membrane endothelial keratoplasty the way forward? Yes.

Authors:  V S Liarakos; M Tsatsos; M Satue; G R J Melles
Journal:  Eye (Lond)       Date:  2017-04-07       Impact factor: 3.775

3.  Analysis of posterior donor corneal parameters 1 year after Descemet stripping automated endothelial keratoplasty (DSAEK) triple procedure.

Authors:  Marco Lombardo; Mark A Terry; Giuseppe Lombardo; David D Boozer; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-01-29       Impact factor: 3.117

4.  Clinical study to estimate correlation between graft thickness as measured by anterior segment Optical Coherence Tomography and visual recovery after manual Descemet stripping endothelial keratoplasty.

Authors:  Rakesh Shetty; Jaya Kaushik; Arun Kumar; Ankita Singh
Journal:  Rom J Ophthalmol       Date:  2022 Apr-Jun

5.  Thinning rate over 24 months in ultrathin DSAEK.

Authors:  Matthew T Fenech; Giulia Coco; Luca Pagano; Kunal A Gadhvi; Mitchell Titley; Hannah J Levis; Mohit Parekh; Stephen B Kaye; Vito Romano
Journal:  Eye (Lond)       Date:  2022-03-15       Impact factor: 4.456

6.  Evaluating DSAEK graft deturgescence in preservation medium after microkeratome cut with optical coherence tomography.

Authors:  Maolong Tang; Christopher Stoeger; Joshua Galloway; Jeffrey Holiman; Matthew R Bald; David Huang
Journal:  Cornea       Date:  2013-06       Impact factor: 2.651

7.  Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty.

Authors:  Gavin S Tan; Mingguang He; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-07-23       Impact factor: 1.930

Review 8.  Phacoemulsification in the Setting of Corneal Endotheliopathies: A Review.

Authors:  Victoria S Chang; Allister Gibbons; Carla Osigian
Journal:  Int Ophthalmol Clin       Date:  2020

9.  Sheets glide-assisted versus Busin glide-assisted insertion techniques for descemet stripping endothelial keratoplasty (DSEK): A comparative analysis.

Authors:  Alok Sati; P S Moulick; Vijay Sharma; Sandeep Shankar
Journal:  Med J Armed Forces India       Date:  2018-04-05

10.  Preparing uniform-thickness corneal endothelial grafts from donor tissues using a non-amplified femtosecond laser.

Authors:  Kanwarpal Singh; Nour Haydari; Isabelle Brunette; Santiago Costantino
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.