Literature DB >> 20707657

Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective.

Long-Jiang Zhang1, Sheng-Yong Wu, Jing Wang, Ying Lu, Zhuo-Li Zhang, Shi-Sen Jiang, Chang-Sheng Zhou, Guang-Ming Lu.   

Abstract

BACKGROUND: Dual-source CT coronary angiography (CTCA) has been used to detect coronary artery disease; however, the factors with potential to affect its diagnostic accuracy remain to be defined.
PURPOSE: To prospectively evaluate the accuracy of dual-source CTCA in diagnosing coronary artery stenosis according to conventional coronary angiography (CAG), and the effect of average heart rate, heart rate variability, and calcium score on the accuracy of CTCA.
MATERIAL AND METHODS: A total of 113 patients underwent both dual-source CTCA and CAG. The results were used to evaluate the findings in dual-source CTCA to assess the accuracy in the diagnosis of > or =50% (significant stenosis) and >75% (severe stenosis) of coronary artery according to those by CAG. Patients were divided into subgroups according to their heart rate (HR), HR variability (HRV), and calcium score, and the accuracy of CTCA was further evaluated. The chi-square test was used to analyze the difference in sensitivity and specificity for the detection of > or =50% and >75% coronary stenosis among subgroups. The generalized estimation equation method was used in per-vessel analysis to adjust for within-patient correlation.
RESULTS: In all, 113 patients had 338 vessels and 1661 segments evaluated by CAG. Dual-source CTCA displayed 1527 segments (91.9%). Among them, 1468 segments (calcium score by CAG score 1, n=1018; score 2, n=270; score 3, n=180) were assessable in CTCA. On a per-patient analysis, the sensitivity and specificity of CTCA were 93.9% and 93.5% for significant stenosis and 86.9% and 98.1% for severe stenosis. On a per-vessel basis, the sensitivity and specificity were 90.2% and 97.1% for significant and 83.3% and 98.1% for severe stenosis. On a per-segment analysis, the sensitivity and specificity were 90.2% and 97.1% for significant and 83.3% and 98.1% for severe stenosis. Average HR had no effect on the sensitivity and specificity of CTCA (P>0.05); whereas HRV and calcium score had some effect on the sensitivity and specificity of CTCA (P<0.05).
CONCLUSION: On a per-patient, per-vessel, and per-segment basis, dual-source CTCA has a high sensitivity and specificity for the diagnosis of coronary artery stenosis. Average HR has no effect on the diagnostic accuracy of CTCA, while HRV and calcium score have a statistically significant effect on the sensitivity and specificity of CTCA.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20707657     DOI: 10.3109/02841851.2010.492792

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  13 in total

Review 1.  MDCT evaluation of atherosclerotic coronary artery disease: what should radiologists know?

Authors:  Hye Rin Kim; Seung Min Yoo; Ji Young Rho; Hwa Yeon Lee; Charles S White
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-01       Impact factor: 2.357

2.  Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

Authors:  Sabine Schueler; Stefan Walther; Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

3.  Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.

Authors:  Long Jiang Zhang; Li Qi; Jing Wang; Chun Xiang Tang; Chang Sheng Zhou; Xue Man Ji; James V Spearman; Carlo Nicola De Cecco; Felix G Meinel; U Joseph Schoepf; Guang Ming Lu
Journal:  Eur Radiol       Date:  2014-04-16       Impact factor: 5.315

Review 4.  Influence of coronary calcification on the diagnostic accuracy of 64-slice computed tomography coronary angiography: a systematic review and meta-analysis.

Authors:  Jawdat Abdulla; Kasper S Pedersen; Matthew Budoff; Klaus F Kofoed
Journal:  Int J Cardiovasc Imaging       Date:  2011-06-12       Impact factor: 2.357

5.  Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Authors:  Junfu Liang; Ying Sun; Ziqing Ye; Yanchun Sun; Lei Xu; Zhen Zhou; Brian Thomsen; Jianying Li; Zhonghua Sun; Zhanming Fan
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

6.  Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography.

Authors:  Long Jiang Zhang; Yining Wang; U Joseph Schoepf; Felix G Meinel; Richard R Bayer; Li Qi; Jian Cao; Chang Sheng Zhou; Yan E Zhao; Xie Li; Jian Bin Gong; Zhengyu Jin; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-09-17       Impact factor: 5.315

Review 7.  Diagnostic performance of coronary CT angiography for stenosis detection according to calcium score: systematic review and meta-analysis.

Authors:  Martijn A M den Dekker; Kristof de Smet; Geertruida H de Bock; Rene A Tio; Matthijs Oudkerk; Rozemarijn Vliegenthart
Journal:  Eur Radiol       Date:  2012-07-15       Impact factor: 5.315

8.  An investigation of correlation between left coronary bifurcation angle and hemodynamic changes in coronary stenosis by coronary computed tomography angiography-derived computational fluid dynamics.

Authors:  Zhonghua Sun; Thanapong Chaichana
Journal:  Quant Imaging Med Surg       Date:  2017-10

Review 9.  Use of 3x2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies.

Authors:  Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  BMJ       Date:  2012-10-24

10.  Prospectively electrocardiogram-gated high-pitch spiral acquisition mode dual-source CT coronary angiography in patients with high heart rates: comparison with retrospective electrocardiogram-gated spiral acquisition mode.

Authors:  Kai Sun; Rui-Juan Han; Li-Jun Ma; Li-Jun Wang; Li-Gang Li; Jiu-Hong Chen
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.