Literature DB >> 20851940

Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

Paul D Deak1, Yulia Smal, Willi A Kalender.   

Abstract

PURPOSE: To determine conversion factors for the new International Commission on Radiological Protection (ICRP) publication 103 recommendations for adult and pediatric patients and to compare the effective doses derived from Monte Carlo calculations with those derived from dose-length product (DLP) for different body regions and computed tomographic (CT) scanning protocols.
MATERIALS AND METHODS: Effective dose values for the Oak Ridge National Laboratory phantom series, including phantoms for newborns; 1-, 5-, and 10-year-old children; and adults were determined by using Monte Carlo methods for a 64-section multidetector CT scanner. For each phantom, five anatomic regions (head, neck, chest, abdomen, and pelvis) were considered. Monte Carlo simulations were performed for spiral scanning protocols with different voltages. Effective dose was computed by using ICRP publication 60 and publication 103 recommendations. The calculated effective doses were compared with those derived from the DLP by using previously published conversion factors.
RESULTS: In general, conversion factors determined on the basis of Monte Carlo calculations led to lower values for adults with both ICRP publications. Values up to 33% and 32% lower than previously published data were found for ICRP publication 60 and ICRP publication 103, respectively. For pediatric individuals, effective doses based on the Monte Carlo calculations were higher than those obtained from DLP and previously published conversion factors (eg, for chest CT scanning in 5-year-old children, an increase of about 76% would be expected). For children, a variation in conversion factors of up to 15% was observed when the tube voltage was varied. For adult individuals, no dependence on voltage was observed.
CONCLUSION: Conversion factors from DLP to effective dose should be specified separately for both sexes and should reflect the new ICRP recommendations. For pediatric patients, new conversion factors specific for the spectrum used should be established.

Entities:  

Mesh:

Year:  2010        PMID: 20851940     DOI: 10.1148/radiol.10100047

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  238 in total

1.  Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose.

Authors:  Eun-Ah Park; Whal Lee; Kwang Woo Kim; Kwang Gi Kim; Allmendinger Thomas; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-21       Impact factor: 2.357

2.  Detection of pulmonary arterial morphology in tetralogy of Fallot with pulmonary atresia by computed tomography: 12 years of experience.

Authors:  Ming-Tai Lin; Jou-Kou Wang; Yih-Sharng Chen; Wen-Jeng Lee; Hsin-Hui Chiu; Chun-An Chen; Shuenn-Nan Chiu; En-Ting Wu; Chun-Wei Lu; Shu-Chien Huang; Shyh-Jye Chen; Ing-Sh Chiu; Chung-I Chang; Mei-Hwan Wu
Journal:  Eur J Pediatr       Date:  2011-11-15       Impact factor: 3.183

3.  DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study.

Authors:  Dominik Geisel; Elke Zimmermann; Matthias Rief; Johannes Greupner; Michael Laule; Fabian Knebel; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2012-04-17       Impact factor: 5.315

4.  In-patient to isocenter KERMA ratios in CT.

Authors:  Walter Huda; Kent M Ogden; Robert L Lavallee; Marsha L Roskopf; Ernest M Scalzetti
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom.

Authors:  Young Jin Ryu; Young Hun Choi; Jung-Eun Cheon; Seongmin Ha; Woo Sun Kim; In-One Kim
Journal:  Pediatr Radiol       Date:  2015-11-06

6.  Updated estimates of typical effective doses for common CT examinations in the UK following the 2011 national review.

Authors:  Paul C Shrimpton; Jan T M Jansen; John D Harrison
Journal:  Br J Radiol       Date:  2015-11-06       Impact factor: 3.039

7.  Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

Authors:  Oliver Rompel; Martin Glöckler; Rolf Janka; Sven Dittrich; Robert Cesnjevar; Michael M Lell; Michael Uder; Matthias Hammon
Journal:  Pediatr Radiol       Date:  2016-01-06

8.  How to Provide Gadolinium-Free PET/MR Cancer Staging of Children and Young Adults in Less than 1 h: the Stanford Approach.

Authors:  Anne M Muehe; Ashok J Theruvath; Lillian Lai; Maryam Aghighi; Andrew Quon; Samantha J Holdsworth; Jia Wang; Sandra Luna-Fineman; Neyssa Marina; Ranjana Advani; Jarrett Rosenberg; Heike E Daldrup-Link
Journal:  Mol Imaging Biol       Date:  2018-04       Impact factor: 3.488

9.  Diagnostic accuracy of third-generation dual-source dual-energy CT: a prospective trial and protocol for clinical implementation.

Authors:  Tim Nestler; Kai Nestler; Andreas Neisius; Hendrik Isbarn; Christopher Netsch; Stephan Waldeck; Hans U Schmelz; Christian Ruf
Journal:  World J Urol       Date:  2018-08-03       Impact factor: 4.226

10.  Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols.

Authors:  D Beitzke; V Berger-Kulemann; V Schöpf; S Unterhumer; E Spitzer; G M Feuchtner; M Gyöngyösi; K Uyanik-Uenal; A Zuckermann; C Loewe; F Wolf
Journal:  Eur Radiol       Date:  2015-04-26       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.