Four-dimensional computed tomography pulmonary ventilation images vary with deformable image registration algorithms and metrics.

Tokihiro Yamamoto1, Sven Kabus, Tobias Klinder, Jens von Berg, Cristian Lorenz, Billy W Loo, Paul J Keall.   

Abstract

PURPOSE: A novel pulmonary ventilation imaging technique based on four-dimensional (4D) CT has advantages over existing techniques and could be used for functional avoidance in radiotherapy. There are various deformable image registration (DIR) algorithms and two classes of ventilation metric that can be used for 4D-CT ventilation imaging, each yielding different images. The purpose of this study was to quantify the variability of the 4D-CT ventilation to DIR algorithms and metrics.
METHODS: 4D-CT ventilation images were created for 12 patients using different combinations of two DIR algorithms, volumetric (DIR(vol)) and surface-based (DIR(sur)), yielding two displacement vector fields (DVFs) per patient (DVF(voI) and DVF(sur)), and two metrics, Hounsfield unit (HU) change (V(HU)) and Jacobian determinant of deformation (V(Jac)), yielding four ventilation image sets (V(HU)(vol), V(HU)(sur), V(Jac)(voI), and V(Jac)(sur). First DVF(vol) and DVF(sur) were compared visually and quantitatively to the length of 3D displacement vector difference. Second, four ventilation images were compared based on voxel-based Spearman's rank correlation coefficients and coefficients of variation as a measure of spatial heterogeneity. V(HU)(vol) was chosen as the reference for the comparison.
RESULTS: The mean length of 3D vector difference between DVF(vol) and DVF(sur) was 2.0 +/- 1.1 mm on average, which was smaller than the voxel dimension of the image set and the variations. Visually, the reference V(HU)(vol) demonstrated similar regional distributions with V(HU)(sur); the reference, however, was markedly different from V(Jac)(vol) and V((Jac)(sur). The correlation coefficients of V(HU)(vol) with V(HU)(sur), V(Jac)(vol) and V(Jac)(sur) were 0.77 +/- 0.06, 0.25 +/- 0.06 and 0.15 +/- 0.07, respectively, indicating that the metric introduced larger variations in the ventilation images than the DIR algorithm. The spatial heterogeneities for V(HU)(vol), 'V(HU)(sur), V(Jac)(vol), and V(Jac)(sur) were 1.8 +/- 1.6, 1.8 +/- 1.5 (p = 0. 85), 0.6 +/- 0.2 (p = 0.02), and 0.7 +/- 0.2 (p = 0.03), respectively, also demonstrating that the metric introduced larger variations.
CONCLUSIONS: 4D-CT pulmonary ventilation images vary widely with DIR algorithms and metrics. Careful physiologic validation to determine the appropriate DIR algorithm and metric is needed prior to its applications.

Entities:  

Mesh:

Year:  2011        PMID: 21520845     DOI: 10.1118/1.3547719

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  4D CT lung ventilation images are affected by the 4D CT sorting method.

Authors:  Tokihiro Yamamoto; Sven Kabus; Cristian Lorenz; Eric Johnston; Peter G Maxim; Maximilian Diehn; Neville Eclov; Cristian Barquero; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Leah Schubert; Quentin Diot; Timothy Waxweiller; Phillip Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Chad Rusthoven; Laurie Gaspar; Brian Kavanagh; Moyed Miften
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-07-15       Impact factor: 7.038

3.  The VAMPIRE challenge: A multi-institutional validation study of CT ventilation imaging.

Authors:  John Kipritidis; Bilal A Tahir; Guillaume Cazoulat; Michael S Hofman; Shankar Siva; Jason Callahan; Nicholas Hardcastle; Tokihiro Yamamoto; Gary E Christensen; Joseph M Reinhardt; Noriyuki Kadoya; Taylor J Patton; Sarah E Gerard; Isabella Duarte; Ben Archibald-Heeren; Mikel Byrne; Rick Sims; Scott Ramsay; Jeremy T Booth; Enid Eslick; Fiona Hegi-Johnson; Henry C Woodruff; Rob H Ireland; Jim M Wild; Jing Cai; John E Bayouth; Kristy Brock; Paul J Keall
Journal:  Med Phys       Date:  2019-02-01       Impact factor: 4.071

4.  Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data.

Authors:  Douglas Brennan; Leah Schubert; Quentin Diot; Richard Castillo; Edward Castillo; Thomas Guerrero; Mary K Martel; Derek Linderman; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh; Yevgeniy Vinogradskiy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-25       Impact factor: 7.038

5.  Treatment planning based on lung functional avoidance is not ready for clinical deployment.

Authors:  Amit Sawant; Tokihiro Yamamoto; Jing Cai
Journal:  Med Phys       Date:  2018-04-14       Impact factor: 4.071

6.  Reproducibility of four-dimensional computed tomography-based lung ventilation imaging.

Authors:  Tokihiro Yamamoto; Sven Kabus; Jens von Berg; Cristian Lorenz; Melody P Chung; Julian C Hong; Billy W Loo; Paul J Keall
Journal:  Acad Radiol       Date:  2012-09-10       Impact factor: 3.173

7.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

8.  Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Chad G Rusthoven; Leah Schubert; Bernard Jones; Austin Faught; Richard Castillo; Edward Castillo; Laurie E Gaspar; Jennifer Kwak; Timothy Waxweiler; Michele Dougherty; Dexiang Gao; Craig Stevens; Moyed Miften; Brian Kavanagh; Thomas Guerrero; Inga Grills
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-10-18       Impact factor: 7.038

9.  Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study.

Authors:  Yevgeniy Vinogradskiy; Phillip J Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-01       Impact factor: 7.038

10.  An assessment of the correlation between robust CT-derived ventilation and pulmonary function test in a cohort with no respiratory symptoms.

Authors:  Girish B Nair; Craig J Galban; Sayf Al-Katib; Robert Podolsky; Maarten van den Berge; Craig Stevens; Edward Castillo
Journal:  Br J Radiol       Date:  2020-12-15       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.