PURPOSE: The aim was to assess personalised contrast media (CM) protocols-based on patient's blood volume (BV) and automated tube voltage selection (ATVS)-in coronary computed tomography angiography (CCTA).Entities:
Mesh:
Substances:
Year: 2018 PMID: 30256835 PMCID: PMC6157854 DOI: 10.1371/journal.pone.0203682
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Patient characteristics, scan settings and preparation of overall population and for different scan protocols.
| Characteristic (n = 114) | Overall | High pitch (n = 81) | AS (n = 33) | p-value |
|---|---|---|---|---|
Note–Values are presented as means ± standard deviation or numbers.
High pitch = prospective ‘high pitch’ scan protocol; AS = prospective ‘adaptive sequence’ scan protocol; BMI = body mass index; BV = blood volume; HR = heart rate; CAD = coronary artery disease; I.v. = intravenous.
†Independent samples T-test showed a significant difference between the two groups.
°Chi-square test showed a significant difference in kV setting between the two groups.
Dose report and comparison for different kV settings.
| Scan parameter | |||||
|---|---|---|---|---|---|
| High pitch (n = 81) | Overall | 70 kV | 80 kV | 90 kV | p-value |
| 505 ± 91 | 462 ±98 | 539 ± 67 | 539 ± 79 | 0.001 | |
| 2.2 ± 1.0 | 1.3 ± 0.3 | 2.5 ± 0.3 | 3.8 ± 0.6 | <0.001 | |
| 72 ± 24 | 51 ± 8 | 80 ± 8 | 111 ± 16 | <0.001 | |
| 0.7 ± 0.3 | 0.5 ± 0.1 | 0.8 ± 0.2 | 1.1 ± 0.2 | <0.001 | |
| 347 ± 71 | 336 ± 79 | 396 ± 26 | 346 ± 15 | 0.237 | |
| 10.6 ± 5.1 | 8.2 ± 2.4 | 14.3 ± 2.6 | 20.9 ± 3.4 | <0.001 | |
| 171 ± 75 | 135 ± 33 | 238 ± 53 | 309 ± 63 | <0.001 | |
| 3.3 ± 1.9 | 2.5 ± 0.9 | 5.1 ± 2.7 | 5.8 ± 2.1 | 0.002 |
Note–Values are presented as means ± standard deviation.
High pitch = prospective ‘high pitch’ scan protocol; AS = prospective ‘adaptive sequence’ scan protocol; CTDI = CT dose index; DLP = dose length product.
†Kruskal-Wallis test showed significance between kV settings.
Injection parameters (mean [ranges]) for both scan protocols for different kV settings.
| High pitch (n = 81) | ||||
|---|---|---|---|---|
| Injection parameter | Sex | 70 kV | 80 kV | 90 kV |
| 3.0 [2.4–4.0] | 4.1 [3.2–5.2] | 4.9 [4.3–5.4] | ||
| 3.7 [2.6–4.4] | 4.8 [4.1–5.5] | 5.8 [5.2–6.7] | ||
| 6.2 [4.9–8.0] | 8.7 [6.9–11.1] | 10.5 [9.0–12.0] | ||
| 7.8 [4.9–8.9] | 10.2 [9.0–12.0] | 12.6 [10.8–14.1] | ||
| 25.1 [19.8–32.9] | 34.8 [26.9–45.0] | 41.5 [37.1–45.9] | ||
| 31.4 [21.8–37.8] | 41.0 [34.9–48.0] | 50.7 [46.0–57.1] | ||
| 7.5 [5.9–9.9] | 10.4 [8.1–13.5] | 12.5 [11.1–13.8] | ||
| 9.4 [6.5–11.3] | 12.3 [10.5–14.4] | 15.2 [13.8–17.1] | ||
| 0.9 [0.7–1.2] | 1.2 [1.0–1.6] | 1.5 [1.3–1.6] | ||
| 1.1 [0.8–1.3] | 1.4 [1.2–1.7] | 1.7 [1.6–2.0] | ||
| 8 [8–9] | 9 [8–9] | 9 [9–9] | ||
| 8 [8–9] | 9 [8–9] | 9 [9–9] | ||
| 3.2 [2.7–3.8] | 3.9 [3.5–4.2] | 5.2 [4.5–5.8] | ||
| 3.9 [3.3–4.5] | 4.7 [4.0–5.4] | 5.8 [5.5–6.0] | ||
| 6.5 [5.0–8.0] | 7.8 [6.8–8.8] | 10.4 [9.0–11.8] | ||
| 8.5 [6.9–10.1] | 9.9 [8.0–12.0] | 12.4 [11.9–12.9] | ||
| 32.8 [27.8–40.1] | 39.8 [35.8–43.8] | 54.3 [46.9–61.7] | ||
| 41.3 [33.9–48.1] | 49.9 [41.7–58.0] | 61.0 [59.1–62.9] | ||
| 9.9 [8.3–12.0] | 11.9 [10.7–13.1] | 16.3 [14.1–18.5] | ||
| 12.4 [10.2–14.4] | 15.0 [12.5–17.4] | 18.3 [17.7–18.9] | ||
| 1.0 [0.8–1.1] | 1.2 [1.1–1.3] | 1.6 [1.4–1.7] | ||
| 1.2 [1.0–1.4] | 1.4 [1.2–1.6] | 1.7 [1.7–1.8] | ||
| 10 [10–11] | 10 [10–10] | 11 [10–11] | ||
| 11 [10–11] | 11 [10–10] | 11 [11–11] | ||
Note–Values are presented as means [range]
High pitch = prospective ‘high pitch’ scan protocol; AS = prospective ‘adaptive sequence’ scan protocol; TIL = total iodine load; IDR = iodine delivery rate; IT = injection time
Overall objective image quality for every scan protocol and kV setting.
| Scan parameter | p-value | ||||
|---|---|---|---|---|---|
| High pitch (n = 81) | Overall | 70 kV | 80 kV | 90 kV | |
| 367 ± 43 | 378 ± 48 | 358 ± 37 | 360 ± 38 | 0.141 | |
| 43 ± 6 | 43 ± 7 | 42 ± 6 | 45 ± 7 | 0.256 | |
| 14 ± 4 | 14 ± 4 | 13 ± 3 | 14 ± 4 | 0.602 | |
| 9 ± 2 | 10 ± 2 | 9 ± 1 | 9 ± 2 | 0.353 | |
| 355 ± 37 | 354 ± 33 | 375 ± 52 | 336 ± 44 | 0.296 | |
| 40 ± 7 | 40 ± 6 | 38 ± 12 | 38 ± 6 | 0.676 | |
| 16 ± 4 | 16 ± 4 | 17 ± 4 | 18 ± 2 | 0.635 | |
| 10 ± 2 | 10 ± 2 | 11 ± 3 | 10 ± 2 | 0.261 |
Note–Values are presented as means ± standard deviation.
High pitch = prospective ‘high pitch’ scan protocol; AS = prospective ‘adaptive sequence’ scan protocol; SD = standard deviation; CNR = contrast-to-noise ratio; SNR = signal-to-noise ratio.