Evaluation of individually body weight adapted contrast media injection in coronary CT-angiography.

Casper Mihl1, Madeleine Kok2, Sibel Altintas3, Bas L J H Kietselaer4, Jakub Turek2, Joachim E Wildberger2, Marco Das2.   

Abstract

OBJECTIVES: Contrast media (CM) injection protocols should be customized to the individual patient. Aim of this study was to determine if software tailored CM injections result in diagnostic enhancement of the coronary arteries in computed tomography angiography (CTA) and if attenuation values were comparable between different weight categories.
MATERIALS AND METHODS: 265 consecutive patients referred for routine coronary CTA were scanned on a 2nd generation dual-source CT. Group 1 (n=141) received an individual CM bolus based on weight categories (39-59 kg; 60-74 kg; 75-94 kg; 95-109 kg) and scan duration ('high-pitch: 1s; "dual-step prospective triggering": 7s), as determined by contrast injection software (Certegra™ P3T, Bayer, Berlin, Germany). Group 2 (n=124) received a standard fixed CM bolus; Iopromide 300 mgI/ml; volume: 75 ml; flow rate: 7.2 ml/s. Contrast enhancement was measured in all proximal and distal coronary segments. Subjective and objective image quality was evaluated. Statistical analysis was performed using SPSS (IBM, version 20.0).
RESULTS: For group 1, mean attenuation values of all segments were diagnostic (>325 HU) without statistical significant differences between different weight categories (p>0.17), proximal vs. distal: 449 ± 65-373 ± 58 HU (39-59 kg); 443 ± 69-367 ± 81 HU (60-74 kg); 427 ± 59-370 ± 61 HU (75-94 kg); 427 ± 73-347 ± 61 HU (95-109 kg). Mean CM volumes were: 55 ± 6 ml (39-59 kg); 61 ± 7 ml (60-74 kg); 71 ± 8 ml (75-94 kg); 84 ± 9 ml (95-109 kg). For group 2, mean attenuation values were not all diagnostic with differences between weight categories (p<0.01), proximal vs. distal: 611 ± 142-408 ± 69 HU (39-59 kg); 562 ± 135-389 ± 98 HU (60-74 kg); 481 ± 83-329 ± 81 HU (75-94 kg); 420 ± 73-305 ± 35 HU (95-109 kg). Comparable image noise and image quality were found between groups (p ≥ 0.330).
CONCLUSIONS: Individually tailored CM injection protocols yield diagnostic attenuation and a more homogeneous enhancement pattern between different weight groups. CM volumes could be reduced for the majority of patients utilizing individualized CM bolus application.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Body weight; Cardiac imaging technique; Computed tomography; Contrast media; Diagnostic imaging

Mesh:

Substances:

Year:  2016        PMID: 26971431     DOI: 10.1016/j.ejrad.2015.12.031

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  6 in total

1.  An Individually Optimized Protocol of Contrast Medium Injection in Enhanced CT Scan for Liver Imaging.

Authors:  Shi-Ting Feng; Hongzhang Zhu; Zhenpeng Peng; Li Huang; Zhi Dong; Ling Xu; Kun Huang; Xufeng Yang; Zhi Lin; Zi-Ping Li
Journal:  Contrast Media Mol Imaging       Date:  2017-07-10       Impact factor: 3.161

2.  High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium.

Authors:  Ruiqi Feng; Jiajie Tong; Xiaofei Liu; Yu Zhao; Liang Zhang
Journal:  Korean J Radiol       Date:  2017-07-17       Impact factor: 3.500

3.  Personalization of injection protocols to the individual patient's blood volume and automated tube voltage selection (ATVS) in coronary CTA.

Authors:  Nienke G Eijsvoogel; Babs M F Hendriks; Jef L Willigers; Bibi Martens; Luc F Carati; Barbora Horehledova; Bastiaan L J H Kietselaer; Harry J G M Crijns; Joachim E Wildberger; Marco Das
Journal:  PLoS One       Date:  2018-09-26       Impact factor: 3.240

4.  Visualisation of coronary venous anatomy by computed tomography angiography prior to cardiac resynchronisation therapy implantation.

Authors:  U C Nguyên; M J M Cluitmans; J G L M Luermans; M Strik; C B de Vos; B L J H Kietselaer; J E Wildberger; F W Prinzen; C Mihl; K Vernooy
Journal:  Neth Heart J       Date:  2018-09       Impact factor: 2.380

5.  Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography (People CT Trial).

Authors:  N G Eijsvoogel; B M F Hendriks; P Nelemans; C Mihl; J Willigers; B Martens; J E Wildberger; M Das
Journal:  Contrast Media Mol Imaging       Date:  2020-01-17       Impact factor: 3.161

6.  Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners.

Authors:  Liang Jin; Yiyi Gao; Yingli Sun; Cheng Li; Pan Gao; Wei Zhao; Ming Li
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.