Literature DB >> 15163812

Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method.

Kyongtae T Bae1, Huy Q Tran, Jay P Heiken.   

Abstract

PURPOSE: To investigate in computed tomographic (CT) angiography whether an exponentially decelerated contrast medium injection, as compared with a standard constant-rate injection, can facilitate uniform vascular contrast enhancement with a reduced contrast material volume.
MATERIALS AND METHODS: CT angiography of the abdominal aorta was performed in 46 subjects by using an exponentially decelerated injection method: 134 mL of contrast medium was injected for 40 seconds, starting at 4.0 mL/sec and decreasing exponentially to 2.7 mL/sec by the end of the injection. Twenty-one of these subjects also underwent CT angiography with a constant-rate injection: 160 mL of contrast medium was injected for 40 seconds at a constant rate of 4 mL/sec. Time-enhancement curves and the magnitude of peak vascular enhancement were measured. Enhancement uniformity was evaluated by using three indexes: (a) duration of contrast enhancement achieved within 80% of the peak (80% DCE), (b) SD of the normalized contrast enhancement (SDNCE) measured from the beginning of spiral CT scanning to the time when the enhancement decreased to a level lower than the beginning level, and (c) slope of the enhancement curve calculated by using linear regression analysis.
RESULTS: Exponentially decelerated injection resulted in more uniform enhancement. Mean values generated by using exponentially decelerated versus constant-rate injection in 21 paired comparisons were, respectively, 30.8 seconds +/- 5.0 versus 22.6 seconds +/- 7.6 for 80% DCE, 0.052 +/- 0.017 versus 0.086 +/- 0.031 for SDNCE, and 0.47 HU/sec +/- 0.70 versus 2.27 HU/sec +/- 0.87 for slope (P <.001 for all indexes). Compared with the peak enhancement resulting from the constant-rate injection, that resulting from the exponentially decelerated injection was reduced by a mean of 17.2% +/- 10.0.
CONCLUSION: Uniform vascular contrast enhancement and reduced contrast medium volume, which are desirable in CT angiography, can be achieved with exponentially decelerated injection. Copyright RSNA, 2004

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15163812     DOI: 10.1148/radiol.2313030497

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice.

Authors:  Wang Yuan; Ting-Ting Qu; Hui-Juan Wang; Mei-Yu Wang; Yuan Qu; Gang Niu; Jian Yang
Journal:  Curr Med Sci       Date:  2019-10-14

3.  Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography.

Authors:  Takeshi Nakaura; Kazuo Awai; Yumi Yanaga; Tomohiro Namimoto; Daisuke Utsunomiya; Toshinori Hirai; Seigo Sugiyama; Hisao Ogawa; Masahito Aoyama; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2011-09-01       Impact factor: 2.374

4.  Minimizing individual variations in arterial enhancement on coronary CT angiographs using "contrast enhancement optimizer": a prospective randomized single-center study.

Authors:  Yoriaki Matsumoto; Toru Higaki; Takanori Masuda; Tomoyasu Sato; Yuko Nakamura; Fuminari Tatsugami; Kazuo Awai
Journal:  Eur Radiol       Date:  2018-11-12       Impact factor: 5.315

5.  Competition of pyruvate with physiological substrates for oxidation by the heart: implications for studies with hyperpolarized [1-13C]pyruvate.

Authors:  Karlos X Moreno; Scott M Sabelhaus; Matthew E Merritt; A Dean Sherry; Craig R Malloy
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-03-05       Impact factor: 4.733

6.  A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.

Authors:  Seung Chai Jung; Seung Hyup Kim; Jeong Yeon Cho
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

7.  Imaging coronary and extracoronary atherosclerosis: feasibility and impact of whole-body computed tomography angiography.

Authors:  Alessandro Napoli; Carlo Catalano; Marco Francone; Vincenzo Sciacca; Iacopo Carbone; Cesare Greco; Michele Anzidei; Francesca Antonella Calabrese; Beatrice Cavallo Marincola; Miles A Kirchin; Annarita Vestri; Marcello Arca; Luigi Iuliano; Roberto Passariello
Journal:  Eur Radiol       Date:  2009-03-11       Impact factor: 5.315

8.  Automatic scan triggering software "confused": Computed tomography angiography in foot arteriovenous malformation!

Authors:  Pankaj Gupta; Anindita Sinha; Niranjan Khandelwal
Journal:  Indian J Radiol Imaging       Date:  2014-04

9.  Recommendations for accurate CT diagnosis of suspected acute aortic syndrome (AAS)--on behalf of the British Society of Cardiovascular Imaging (BSCI)/British Society of Cardiovascular CT (BSCCT).

Authors:  Varut Vardhanabhuti; Edward Nicol; Gareth Morgan-Hughes; Carl A Roobottom; Giles Roditi; Mark C K Hamilton; Russell K Bull; Franchesca Pugliese; Michelle C Williams; James Stirrup; Simon Padley; Andrew Taylor; L Ceri Davies; Roger Bury; Stephen Harden
Journal:  Br J Radiol       Date:  2016-02-26       Impact factor: 3.039

10.  Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency.

Authors:  Markus M Schreiner; Hannes Platzgummer; Sylvia Unterhumer; Michael Weber; Gabriel Mistelbauer; Eduard Groeller; Christian Loewe; Ruediger E Schernthaner
Journal:  Cardiovasc Intervent Radiol       Date:  2017-12-07       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.