| Literature DB >> 30254675 |
Rafaella Caramori Saab1, Leonardo Fernandes da Cunha2, Carla Castiglia Gonzaga2, Amanda Mahammad Mushashe3, Gisele Maria Correr2.
Abstract
PURPOSE: The aim of the study was to measure the marginal and internal adaptation (MIA) of zirconia copings, made of 4 ceramic systems for CAD/CAM, using microcomputed tomography (micro-CT) technology.Entities:
Year: 2018 PMID: 30254675 PMCID: PMC6145157 DOI: 10.1155/2018/5189767
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Group distribution and material specification (n=10).
| Group | CAD/CAM system | Ceramic system | Manufacturer | Ceramic system composition |
|---|---|---|---|---|
| CC | CEREC | In Coris Zi | Sirona Dental Systems, Bensheim, Germany | Zirconium dioxide + hafnium dioxide + yttrium trioxide >99 wt.%, aluminum trioxide <0.5 wt.%, others oxides <0.5 wt.% |
| CN | CERCON | Cercon base | Dentsply International, Susquehanna Commerce Center, York, USA | Yttrium trioxide 4.5–5.4 wt.%, hafnium dioxide <5 wt.%, aluminum trioxide <0.5 wt.%, silicon dioxide <0.1 wt.%, sodium oxide <0.1 wt.%, iron trioxide <0.1 wt.%, zirconium dioxide balance |
| CL | CERAMILL | Ceramill Zi | Amann Girrbach North America, Charlotte, USA | Zirconium dioxide + hafnium dioxide + yttrium trioxide >99 wt.%, yttrium trioxide 8.5–9.5 wt.%, hafnium dioxide <5 wt.%, aluminum trioxide <0.5 wt.%, other oxides <1 wt.% |
| LA | LAVA | Lava Frame Zirconia | 3M, St. Paul, USA | Zirconium oxide 79–97%, yttrium oxide 3–15%, hafnium oxide <5% |
Software and milling specifications for each CAD/CAM system.
| Group | Software | Milling machine | Number of axes | Milling tools/burs |
|---|---|---|---|---|
| CC | CEREC SW 4.2.4 | inLab MC XL CEREC | 2 | Cylinder pointed bur 12S and 12 EF and cylinder bur 12 EF |
| CN | CERCON ART 3.2 | CERCON Brain | 4 | Parallel burs 10.0 and conical burs 4° |
| CL | Ceramill mind | Ceramill Motion 2 | 5 | Ceramill Roto Motion 0.6; 1.0 and 2.5 |
| LA | LAVA CAD | LAVA Form Milling Unit | 3 | Lava milling bur types 4 and 5 |
Mean (µm) and standard deviation (SD) values for the different groups after fit measurement (n=10).
| Points | CC | CN | CL | LA |
|---|---|---|---|---|
| MG | 37.68 ± 9.04a | 57.40 ± 8.71bcd | 52.50 ± 10.18abc | 62.70 ± 11.11bcd |
| AW | 47.50 ± 9.00ab | 61.93 ± 15.37bcd | 55.48 ± 7.79 bc | 69.05 ± 10.54cde |
| AO | 54.53 ± 8.49abc | 56.52 ± 10.16bcd | 62.68 ± 9.72bcd | 82.40 ± 16.65e |
| CO | 59.98 ± 7.53bcd | 73.40 ± 12.98de | 65.90 ± 8.04cde | 108.85 ± 18.01f |
Values with different superscript letters are significantly different (Tukey p > 0.05). CC, Cerec; CN, Cercon; CL, Ceramill; LA, Lava; MG, marginal gap; AW, axial wall; AO, axio-occlusal angle; CO, central of occlusal area.