Ji Suk Shim1, Jin Sook Lee2, Jeong Yol Lee3, Yeon Jo Choi2, Sang Wan Shin3, Jae Jun Ryu2. 1. Department of Prosthodontics, Ansan Hospital, Korea University, Gyeonggi-do, Republic of Korea. 2. Department of Prosthodontics, Anam Hospital, Korea University, Seoul, Republic of Korea. 3. Department of Prosthodontics, Guro Hospital, Korea University, Seoul, Republic of Korea.
Abstract
OBJECTIVE: This study investigated the marginal and internal adaptation of individual dental crowns fabricated using a CAD/CAM system (Sirona's BlueCam), also evaluating the effect of the software version used, and the specific parameter settings in the adaptation of crowns. MATERIAL AND METHODS: Forty digital impressions of a master model previously prepared were acquired using an intraoral scanner and divided into four groups based on the software version and on the spacer settings used. The versions 3.8 and 4.2 of the software were used, and the spacer parameter was set at either 40 μm or 80 μm. The marginal and internal fit of the crowns were measured using the replica technique, which uses a low viscosity silicone material that simulates the thickness of the cement layer. The data were analyzed using a Friedman two-way analysis of variance (ANOVA) and paired t-tests with significance level set at p<0.05. RESULTS: The two-way ANOVA analysis showed the software version (p<0.05) and the spacer parameter (p<0.05) significantly affected the crown adaptation. The crowns designed with the version 4.2 of the software showed a better fit than those designed with the version 3.8, particularly in the axial wall and in the inner margin. The spacer parameter was more accurately represented in the version 4.2 of the software than in the version 3.8. In addition, the use of the version 4.2 of the software combined with the spacer parameter set at 80 μm showed the least variation. On the other hand, the outer margin was not affected by the variables. CONCLUSION: Compared to the version 3.8 of the software, the version 4.2 can be recommended for the fabrication of well-fitting crown restorations, and for the appropriate regulation of the spacer parameter.
OBJECTIVE: This study investigated the marginal and internal adaptation of individual dental crowns fabricated using a CAD/CAM system (Sirona's BlueCam), also evaluating the effect of the software version used, and the specific parameter settings in the adaptation of crowns. MATERIAL AND METHODS: Forty digital impressions of a master model previously prepared were acquired using an intraoral scanner and divided into four groups based on the software version and on the spacer settings used. The versions 3.8 and 4.2 of the software were used, and the spacer parameter was set at either 40 μm or 80 μm. The marginal and internal fit of the crowns were measured using the replica technique, which uses a low viscosity silicone material that simulates the thickness of the cement layer. The data were analyzed using a Friedman two-way analysis of variance (ANOVA) and paired t-tests with significance level set at p<0.05. RESULTS: The two-way ANOVA analysis showed the software version (p<0.05) and the spacer parameter (p<0.05) significantly affected the crown adaptation. The crowns designed with the version 4.2 of the software showed a better fit than those designed with the version 3.8, particularly in the axial wall and in the inner margin. The spacer parameter was more accurately represented in the version 4.2 of the software than in the version 3.8. In addition, the use of the version 4.2 of the software combined with the spacer parameter set at 80 μm showed the least variation. On the other hand, the outer margin was not affected by the variables. CONCLUSION: Compared to the version 3.8 of the software, the version 4.2 can be recommended for the fabrication of well-fitting crown restorations, and for the appropriate regulation of the spacer parameter.
Digital impression systems using intraoral scanning have been available since the introduction of CEREC 1 (Sirona’s BlueCam) as part of the single-sitting dental appointment concept
. These systems offer remarkable benefits compared with conventional impression methods, including easier data storage, smaller storage requirements, more time-efficient treatment procedures, and an increase in patient comfort
. However, restorations fabricated with the first digital impression systems available showed relatively poor marginal adaptation compared to the ones made with conventional impression methods
; therefore, some authors expressed concerns on the longevity of the restorations, since adequate marginal adaptation is a decisive factor for clinical longevity
. On the other hand, technical advances have significantly improved the adaptation of restorations fabricated with digital impression systems; a recent study demonstrated that a complete crown fabricated using intraoral scanning resulted in a better marginal fit than crowns created with conventional techniques
.The process of fabricating restorations using digital impressions and “computer-aided-design/computer-aided-manufacturing” (CAD/CAM) technology comprises the following steps: data acquisition, data processing, and manufacturing. These steps are equally important for the fabrication of well-fitting restorations, and errors in any of these steps may result in distortions of the restorations
. Therefore, the scanning procedure, the specific software, and the milling machine used have all been suggested as factors that could have a detrimental effect on the fit of restorations fabricated with the CAD/CAM technology
,
. As a consequence, a number of studies have been performed to compare marginal and internal adaptation of restorations scanned with different intraoral scanners or fabricated made with different milling machines. However, to perform accurate comparisons it is also essential to take into account the software version used with each CAD/CAM system and the specific parameter settings (i.e. spacer settings) selected. Despite the importance of these factors, few studies have assessed their effect on marginal and internal adaptation of crown restorations. Therefore, the purpose of this study was to evaluate marginal and internal adaptation of restorations fabricated with different versions of the CAD/CAM software and the effect of different parameter settings.
MATERIAL AND METHODS
Fabrication of the reference model
An acrylic model of the maxillary left second molar was prepared to receive a single ceramic crown restoration (Nissin Dental Model, Nissin Dental Prod. Inc., Kyoto, Kyoto, Japan). The preparation featured a 1-mm-deep chamfer finish line with a total convergence angle of 12 degrees. To verify a standardized tooth reduction, an initial impression was taken with a vinyl polysiloxane material (Aquasil Soft Putty, Dentsply DeTrey GmbH, Konstanz, Baden-Württemberg, Germany) before preparation. This impression was sectioned vertically (at a width of 2 mm), and set in the place of the prepared model. The depth needed for tooth preparation was estimated by comparing the impression body and the prepared model. For repeated measurements, a titanium replica of the acrylic model was made using a customized CAD/CAM system (Myplant, Addtech Co., Seoul, Seoul, Korea).
Acquisition of digital impressions
A thin uniform layer of an antireflection powder (CEREC Optispray, Sirona Dental Systems GmbH, Bensheim, Hesse, Germany) was sprayed on the reference model. Digital impressions were taken using a CEREC AC with Bluecam (Sirona’s BlueCam, Sirona Dental Systems GmbH, Bensheim, Hesse, Germany) system according to the scanning protocol of Ender and Mehl
(2013), including occlusal views with scans at an angle of 30 degree from the buccal and lingual surfaces
. One single dentist trained in taking digital impressions acquired 40 digital impressions of the reference model.
Data processing and fabrication of single crowns
The 40 digital impressions acquired were first divided into two groups (n=20 each), depending on the software version that was used in the processing (i.e., CEREC version 3.8 or version 4.2). Each group was further divided into two subgroups (n=10 each), depending on the spacer parameter settings (i.e., 40 or 80 μm) (Table 1). The acquired datasets were transmitted to a milling unit (CEREC MCXL, Sirona Dental Systems GmbH, Bensheim, Hesse, Germany), and crowns were fabricated using LavaTM Ultimate Restorative milling blocks (3M ESPE, St. Paul, Minnesota, USA).
Table 1
Two-way ANOVA analysis showing that software version and spacer parameter significantly affected the fit of the crowns (p<.05)
Independent variable
Significance
Software Version
p<0.05
Space Parameter
p<0.05
Evaluation of crown adaptation
The replica technique previously described by Molin and Karlsson
(1993), and validated by Rahme, et al.
(2008) and Laurent, et al.
(2008), was used to evaluate the adaptation of crowns. The crowns were filled with a low viscosity silicone material (Fit Checker, GC Dental, Tokyo, Tokyo, Japan), and placed in the titanium reference model using a Shimadzu universal tester (AG-10KNX, Shimadzu Co, Tokyo, Tokyo, Japan) with a 20 N load. After 5 minutes, the silicone material attached to the internal surface of the crowns was removed and then stabilized with the impression material of higher viscosity (Examixfine regular type, GC Dental, Tokyo, Tokyo, Japan).All replicas were cut along the abutment axis both in the buccolingual and in the mesiodistal direction, using a razor blade, yielding four fragments per crown. For each cross section, four points were measured, thus 16 thickness points of the titanium replica were measured (Figure 1). The points from “1” to “8” were included in the buccolingual direction section, and the points from “a” to “h” were included in the mesiodistal direction section. The measuring points were divided into 4 categories considering the location of tooth: margin (1, 8, a, h), lower axial wall (2, 7, b, g), upper axial wall (3, 6, c, f), and occlusal surface (4, 5, d, e).
Figure 1
Groups defined for the study
All analyses were performed using a double-blind protocol. Replica film thickness was measured with a video measuring system (Optical video measuring system, Seven Ocean Optical Technology, Donnguan, Guangdong, China) at a 10X magnification with external light source.
Statistical analysis
The mean and the standard deviation of the fit accuracy were calculated for each group. The influence of independent variables, including the ones from the software and from the spacer parameters, were analyzed using a Friedman two-way analysis of variance (ANOVA) (p=.05). A post hoc analysis was performed using the Friedman multiple comparisons.The groups within each category (margin, lower axial wall, upper axial wall, occlusal surface) were merged, and the mean and the standard deviation of each category were calculated. The comparisons between groups within each category were conducted using paired t-tests (p<05). All statistical analyses were carried out with MedCalc version 12.5.0 (MedCalc Software, Ostend, Vlaanderen, Belgium).
RESULTS
The accuracy of the fit at each measuring point for each experimental group is summarized in Figures 2 to 6. Statistical significances between groups were demonstrated in Figures 7 and 8. The results drawn from the average values of the same categorized measuring points are shown in Figure 9. The two-way ANOVA analysis showed the software version and the spacer parameter significantly affected the fit of crowns (p<.05) (Table 1).
Figure 2
Measuring points for evaluation of crown fit. The points 1 to 8 are positioned on the buccolingually sectioned surface, and a to h are on the mesiodistally sectioned surface. Points of 1, 8, a, h are positioned on the margin, 2, 7, b, g are on the lower axial wall, 3, 6, c, f are on the upper axial wall, and 4, 5, d, e are on the occlusal surface
Figure 6
Accuracy of fit of each measuring point in group 4 (CEREC SW 4.2, 80 mm). Uppermost point and lowermost point indicate the highest and lowest values of results. The top of box and bottom of box indicate the 75% and 25% values of results. The midline in the box means the average of the results
Figure 7
Mean internal fit (mm) of each measuring points on buccolingually sectioned surface. *indicates statistically significant differences
Figure 8
Mean internal fit (mm) of each measuring points on mesiodistally sectioned surface. *indicates statistically significant differences
Figure 9
The results of each average values of measuring points categorized as margin (1, 8, a, h), lower axial wall (2, 7, b, g), upper axial wall (3, 6, c, f) and occlusal suface (4, 5, d, e). *indicates statistically significant differences
The accuracy of the fit of all measuring points on the margin (1, 8, a, h) showed no statistical significant difference between groups, and the average values of measuring points categorized as the margin also showed no significant difference (p>.05). On the lower and on upper axial wall, some specific measuring points (i.e., points 2 and g of the lower axial wall; points 3 and f of the upper axial wall) showed a significantly larger gap when data were processed using the version 3.8 of the software compared with the version 4.2 of the software, regardless of the spacer settings used. Measuring points 6 (upper axial wall) and 7 (lower axial wall) showed a significantly larger gap using the version 3.8 of the software compared with the 4.2 of the software when the spacer parameter was set at 40 μm (p<.05). The comparison of the average values of the measuring points categorized as lower axial wall and upper axial wall showed a significantly larger gap using the version 3.8 of the software, regardless of the spacer parameter used (p<.05). In the occlusal surface, measuring points d and e showed a significantly larger gap when the data were processed using the version 3.8 of the software compared with the version 4.2 of the software, regardless of the spacer parameter used; while measuring point 4 showed the same result only when the spacer parameter was set at 80 μm (p<.05). The comparison of the average values of the occlusal surface showed the group processed with the version 3.8 of the software had a larger gap compared with the group processed with the version 4.2 of the software only when the spacer parameter was set at 40 μm (p<.05).Although we expected the larger spacer parameter setting would have caused a larger gap between crown and tooth, the use of 40 μm as the spacer parameter setting in the version 3.8 of the software produced a larger gap when compared to the setting of the spacer at 80 μm for the six measuring points, including 5 (occlusal surface), 6 (upper axial wall), a (margin), b (lower axial wall), c (upper axial wall), and h (margin). On the contrary, for the version 4.2 of the software, one measuring point (i.e., point 6 of upper axial wall) showed a smaller gap with a 40 μm spacer setting when compared with the group selecting 80 μm, while the group selecting 80 μm in the version 4.2 of the software showed the least variations among the results.
DISCUSSION
The process of dental restorations using CAD/CAM technology involves data acquisition, data processing, and manufacturing. The aim of this study was to evaluate the effect of data processing on the adaptation of crown restorations. Variables such as different versions of software and space parameters were analyzed in the four groups of crown impressions, and the fit of the crown was measured using the replica technique. As the results showed, the crowns designed using the version 4.2 of the software produced a better fit than those designed using the version 3.8 of the software, particularly in the axial wall. The spacer parameter was more accurately represented in the version 4.2 of the software than in the version 3.8. In addition, the use of the version 4.2 of the software combined with the spacer parameter set at 80 μm showed the least variation. On the other hand, the outer margin was not affected by the variables.Such parameters indicate the setting factors to determine particular features of a restoration in CAD/CAM system. The cement space, the contact strength, the occlusion strength, and the minimum thickness of a restoration can be easily changed as providing different parameter in the CAD/CAM system. Space parameter can be set from -100 to 100 μm in the version 3.8, and from 0 to 100 μm in the version 4.2. Among the overlapped space parameter (from 0 to 100 μm), 40 and 80 μm were used in this study. Forty μm is commonly used as space parameter because resin cements range from 20 to 35 μm concerning the thickness of their film; the 80 μm is the double value of 40 μm to evaluate the effect of space parameter.To fabricate well-fitting dental crowns using CAD/CAM systems in the clinic, the optimal combination involving the intraoral scanner, the software version, and the milling machine is important. Although many studies have compared the fit of crown restorations fabricated with different intraoral scanners
,
and milling machines
, there have been few studies evaluating the effect of different versions of the software. The results of this study showed the fit of a restoration could be affected by the software version and the spacer parameter setting, even when the same scanner and milling machine were used. Compared to the version 3.8 of the CAD/CAM software, the version 4.2 of this software can be recommended for the fabrication of well-fitting crown restorations, and for the appropriate regulation of the spacer parameter. Even though the 80-μm spacer setting produced a larger gap, this setting could be recommended for the version 4.2 of the CAD/CAM software because it showed a good repeatability.Adequate marginal gaps and internal fits are decisive factors for the clinical longevity of crown restorations
. A large marginal gap can cause discoloration, disintegration of cement, plaque retention, and gingival inflammation
,
. The recommended marginal gap for the prevention of the above mentioned complications
,
is below 100 μm. The results obtained in this study showed a clinically acceptable marginal fit could be achieved regardless of the software version and of the spacer parameter settings, with an average gap of 35 μm. A larger internal gap could produce restorative fractures and postoperative sensitivity. The results of this study demonstrated the version 3.8 of the software and the spacer parameter set at 40 μm produced a relatively larger internal gap when compared with the version 4.2 of the software and with the spacer parameter set at 80 μm. The use of a sufficient amount of cement with harder mechanical properties is recommended in these cases to avoid the complications caused by large internal gaps.Although zirconia is one of the most popular materials used in the fabrication of crowns by utilizing the CAD/CAM system, the additional process of sintering may introduce variability among crowns. For the accurate evaluation of the effect of the version of the software and of the spacer parameter settings, LavaTM Ultimate Restorative, a resin of nano ceramic material that does not require the sintering process was selected as the restoration material in this study
. Compared with previous studies
,
, the smaller marginal and internal gaps reported in this study could be due to the use of a different restoration material. The marginal adaptation was evaluated using the replica technique. Although measurements using a digital 3D scanner are precise, convenient, and easily visualized, the replica technique is the appropriate measurement tool for the accurate assessment of multiple points in the internal surface of restorations fabricated using the CAD/CAM system
.The generally recognized improvement introduced by the version 4.2 of the software compared with the version 3.8 is an increased convenience for the use of the CEREC CAD/CAM system. The version 4.2.5 is already available these days, being a supplementary version of the 4.2 and it does not seem to have big functional differences with the version 4.2. The results of this study showed that a smaller internal gap could be obtained using the version 4.2 of the software, particularly at the axial wall, despite the fact the marginal gap was almost the same. The improvement of the adaptation obtained with the version 4.2 of the software could be in part due to differences in the pre-set space, basically providing space regardless of the parameter setting at the internal part between software versions. It has been shown that a greater internal space resulted in less marginal gap leading to less internal premature contact
; a greater internal space might be necessary for achieving an adequate marginal gap in crown restorations, taking into account the accuracy and reproducibility of intraoral scanners and milling machines that are currently used with the version 3.8 of the software. Another possible explanation could be the improvement in resolution of the version 4.2 of the software during the processing of the acquired data through the intraoral scanner.The application of the CAD/CAM technology in dentistry have been producing improvement not only in dental clinics but also in dental laboratories
. Many studies are using the AD/CAM technology to compare it with conventional methods or to manage it as a tool to measure specimens. Our results suggest that, to achieve accurate comparisons across studies, all reports should specify the software version and the space parameter settings used (additional studies of reference on the effect of various software and parameters will be necessary).
CONCLUSIONS
The fit of a crown restoration can be affected by the specific CAD/CAM software version and by the parameter settings selected, even if the same scanner and milling machine were used. In comparison with the version 3.8 of the CAD/CAM software, the version 4.2 of this software can be recommended for the fabrication of well-fitting crown restorations, and for the appropriate regulation of the spacer parameter. Even though the 80-μm spacer setting produced a larger gap, this setting can be recommended for the version 4.2 of the CAD/CAM software because it has shown a good repeatability.
Authors: Fabio Kricheldorf; Cleuber Rodrigo de Souza Bueno; Wilson da Silva Amaral; Joel Ferreira Santiago Junior; Hugo Nary Filho Journal: Eur J Dent Date: 2018 Jan-Mar
Authors: Gilberto Sammartino; David M Dohan Ehrenfest; Jamil A Shibli; Pablo Galindo-Moreno Journal: Biomed Res Int Date: 2016-03-17 Impact factor: 3.411
Authors: Heike Rudolph; Silke Ostertag; Michael Ostertag; Michael H Walter; Ralph Gunnar Luthardt; Katharina Kuhn Journal: J Appl Oral Sci Date: 2018-02-01 Impact factor: 2.698
Authors: Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann Journal: Int J Environ Res Public Health Date: 2020-03-25 Impact factor: 3.390