Literature DB >> 24036977

Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology.

Márcia Borba1, Walter Gomes Miranda, Paulo Francisco Cesar, Jason Allan Griggs, Alvaro Della Bona.   

Abstract

The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm). OA had the highest median gap dimension (125 µm), followed by the AOT point (105 µm). CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24036977     DOI: 10.1590/S1806-83242013000500003

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  9 in total

1.  Evaluation of microleakage in class V composite restorations using dye penetration and micro-CT.

Authors:  S Jacker-Guhr; G Ibarra; L S Oppermann; A-K Lührs; A Rahman; W Geurtsen
Journal:  Clin Oral Investig       Date:  2015-12-05       Impact factor: 3.573

2.  Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images.

Authors:  Letícia Queiroz Mauad; Paulo Victor Teixeira Doriguêtto; Daniela de Almeida; Karolina Aparecida Castilho Fardim; Alessiana Helena Machado; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

3.  Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique.

Authors:  Necla Demir; Atiye Nilgun Ozturk; Meral Arslan Malkoc
Journal:  Eur J Dent       Date:  2014-10

4.  Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study.

Authors:  Sibel Cetik; Babak Bahrami; InÈs Fossoyeux; Ramin Atash
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

5.  Feasibility of micro-computed tomography to detect and classify proximal caries lesions in vitro.

Authors:  Karla Rovaris; Liana Matos Ferreira; Thiago Oliveira Sousa; Leonardo Vieira Peroni; Deborah Queiroz Freitas; Ann Wenzel; Francisco Haiter-Neto
Journal:  Dent Res J (Isfahan)       Date:  2018 Mar-Apr

6.  Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions.

Authors:  Per Svanborg; Henrik Skjerven; Pablo Carlsson; Alf Eliasson; Stig Karlsson; Anders Ortorp
Journal:  Int J Dent       Date:  2014-03-03

Review 7.  Three-dimensional imaging techniques: A literature review.

Authors:  Orhan Hakki Karatas; Ebubekir Toy
Journal:  Eur J Dent       Date:  2014-01

8.  Misfit and fracture load of implant-supported monolithic crowns in zirconia-reinforced lithium silicate.

Authors:  Rafael Soares Gomes; Caroline Mathias Carvalho de Souza; Edmara Tatiely Pedroso Bergamo; Dimorvan Bordin; Altair Antoninha Del Bel Cury
Journal:  J Appl Oral Sci       Date:  2017 May-Jun       Impact factor: 2.698

9.  Micro-CT Analysis of Y-TZP Copings Made by Different CAD/CAM Systems: Marginal and Internal Fit.

Authors:  Rafaella Caramori Saab; Leonardo Fernandes da Cunha; Carla Castiglia Gonzaga; Amanda Mahammad Mushashe; Gisele Maria Correr
Journal:  Int J Dent       Date:  2018-09-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.