Literature DB >> 30202612

Corneal Biomechanical Properties of Keratoconic Eyes Following Penetrating Keratoplasty.

Hamidu Gobeka1, Özlem Barut Selver1, Melis Palamar Onay1, Sait Eğrilmez1, Ayşe Yağcı1.   

Abstract

OBJECTIVES: To investigate the corneal biomechanical properties of keratoconic eyes following penetrating keratoplasty (PKP).
MATERIALS AND METHODS: Thirty-five patients (70 eyes) were enrolled to this prospective study. Operated and contralateral keratoconic eyes were defined as Group 1 and 2, respectively. All patients underwent ophthalmological examination and measurements of corneal biomechanical properties by Ocular Response Analyzer (ORA), intraocular pressure (IOP) by Goldmann applanation tonometry, and central corneal thickness (CCT) by Pentacam. Shapiro-Wilk W test was performed to test normality of the data. The statistical significance was evaluated with the paired t-test and Wilcoxon signed ranks test. Pearson correlation and Spearman rho tests were used for correlation analysis.
RESULTS: The average age and male/female ratio were 31.34±11.65 (15-60) years and 21/14, respectively. The mean values of the data obtained from Group 1 and 2 respectively were: corneal hysteresis (CH): 9.35±1.66, 8.18±1.84 mmHg (p=0.013), corneal resistance factor (CRF): 9.48±1.96, 7.14±2.05 mmHg (p<0.001), IOPcc: 16.90±4.32, 14.26±3.69 mmHg (p=0.004), IOPg: 15.45±4.61, 10.91±3.97 mmHg (p<0.001), IOPapl: 14.26±3.11, 13.09±2.54 mmHg (p=0.046), and central corneal thickness (CCT): 545.64±60.82, 442.60±68.14 μM (p<0.001). The positive correlation between CH and CRF was moderate (r=0.444) in Group 1 and strong (r=0.770) in Group 2. There was a moderate negative correlation between CH and IOPcc in both groups (r=-0.426, r=-0.423), but CH was not correlated with IOPg or IOPapl in either group. There were weak to strong positive correlations between CRF and all IOP values in both groups. There was no correlation between CRF and CCT in Group 1 (r=0.075) and a very weak correlation in Group 2 (r=0.237). Only IOPcc and IOPg were strongly correlated in both groups.
CONCLUSION: Better understanding of corneal biomechanical properties is essential for elucidating the pathophysiology and diagnosis of several corneal pathologies such as keratoconus. The biomechanical properties of keratoconic eyes seem to be closer to normal values after PKP.

Entities:  

Keywords:  Corneal biomechanical properties; Ocular Response Analyzer; keratoconus; penetrating keratoplasty

Year:  2018        PMID: 30202612      PMCID: PMC6126104          DOI: 10.4274/tjo.79664

Source DB:  PubMed          Journal:  Turk J Ophthalmol        ISSN: 2149-8709


  50 in total

1.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

2.  Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis.

Authors:  Jun Liu; Cynthia J Roberts
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

3.  Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes.

Authors:  Dolores Ortiz; David Piñero; Mohamed H Shabayek; Francisco Arnalich-Montiel; Jorge L Alió
Journal:  J Cataract Refract Surg       Date:  2007-08       Impact factor: 3.351

4.  Graft biomechanical properties after penetrating keratoplasty versus deep anterior lamellar keratoplasty.

Authors:  Mohammad Reza Jafarinasab; Sepehr Feizi; Mohammad Ali Javadi; Ali Hashemloo
Journal:  Curr Eye Res       Date:  2011-05       Impact factor: 2.424

5.  Corneal biomechanical metrics and anterior segment parameters in mild keratoconus.

Authors:  Bruno M Fontes; Renato Ambrósio; Daniela Jardim; Guillermo C Velarde; Walton Nosé
Journal:  Ophthalmology       Date:  2010-04       Impact factor: 12.079

6.  Comparison of IOP measurements between ORA and GAT in normal Chinese.

Authors:  Andrew Lam; Davie Chen; Roger Chiu; Wan-Sang Chui
Journal:  Optom Vis Sci       Date:  2007-09       Impact factor: 1.973

7.  Effect of aging on corneal biomechanical parameters using the ocular response analyzer.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Fumiko Ohmoto
Journal:  J Refract Surg       Date:  2009-10-12       Impact factor: 3.573

8.  Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer.

Authors:  Caitriona Kirwan; Donal O'Malley; Michael O'Keefe
Journal:  Ophthalmologica       Date:  2008-07-15       Impact factor: 3.250

9.  Influence of age and gender on corneal biomechanical properties in a healthy Italian population.

Authors:  Ernesto Strobbe; Mauro Cellini; Umberto Barbaresi; Emilio C Campos
Journal:  Cornea       Date:  2014-09       Impact factor: 2.651

10.  Changes in corneal biomechanics following different keratoplasty techniques.

Authors:  Mohamed Hosny; Mohamed Abdel Moneim Hassaballa; Ahmed Shalaby
Journal:  Clin Ophthalmol       Date:  2011-06-09
View more
  1 in total

1.  Corneal biomechanics and intraocular pressure assessment after penetrating keratoplasty for non keratoconic patients, long term results.

Authors:  Mohamed Samy Abd Elaziz; Hoda Mohamed Elsobky; Adel Galal Zaky; Eslam Ahmed Maher Hassan; Mahmoud Tawfik KhalafAllah
Journal:  BMC Ophthalmol       Date:  2019-08-07       Impact factor: 2.209

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.