Literature DB >> 21501074

Graft biomechanical properties after penetrating keratoplasty versus deep anterior lamellar keratoplasty.

Mohammad Reza Jafarinasab1, Sepehr Feizi, Mohammad Ali Javadi, Ali Hashemloo.   

Abstract

PURPOSE: To compare biomechanical properties of transplanted corneas after penetrating keratoplasty (PK) with those after deep anterior lamellar keratoplasty (DALK) using Anwar's big-bubble technique.
MATERIALS AND METHODS: This cross-sectional comparative study consisted of 45 PK eyes (group 1) and 23 DALK eyes (group 2) with the underlying pathology of keratoconus. The Ocular Response Analyzer was used to measure Goldmann-correlated intraocular pressure (IOPg) and cornea-compensated IOP (IOPcc), as well as graft biomechanical properties, namely corneal hysteresis (CH) and corneal resistance factor (CRF). The results were compared between the study groups using independent t-test.
RESULTS: Mean patient age was 29.8 ± 6.1 years in group 1 and 27.2 ± 6.5 years in group 2 (P = 0.11) and they were followed up for 31.4 ± 19.0 months and 29.2 ± 17.3 months after corneal transplantation, respectively (P = 0.27). There was no significant difference between the study groups in terms of recipient (P = 0.21) and donor (P = 0.57) trephine sizes or BSCVA (P = 0.77). CH was measured 10.09 ± 2.5 mmHg in group 1 and 9.64 ± 2.1 mmHg in group 2 (P = 0.36). CRF was 10.13 ± 2.2 and 9.36 ± 2.1 mmHg, respectively (P = 0.17). Similarly, no significant difference was found between group 1 and group 2 in terms of IOPg (P = 0.25) and IOPcc (P = 0.80).
CONCLUSION: DALK using the big-bubble technique for keratoconic eyes provides corneal biomechanics comparable to PK.

Entities:  

Mesh:

Year:  2011        PMID: 21501074     DOI: 10.3109/02713683.2011.556303

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  11 in total

1.  Corneal biomechanical properties in eyes with no previous surgery, with previous penetrating keratoplasty and with deep anterior lamellar keratoplasty.

Authors:  Banu Torun Acar; Mehmet Orcun Akdemir; Suphi Acar
Journal:  Jpn J Ophthalmol       Date:  2012-11-03       Impact factor: 2.447

2.  Corneal biomechanical properties in 3 corneal transplantation techniques with a dynamic Scheimpflug analyzer.

Authors:  Naoyuki Maeda; Ryotaro Ueki; Mutsumi Fuchihata; Hisataka Fujimoto; Shizuka Koh; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2014-09-05       Impact factor: 2.447

3.  Vector analysis of femtosecond laser-assisted astigmatic keratotomy after deep anterior lamellar keratoplasty and penetrating keratoplasty.

Authors:  Fouad anNakhli; Ashbala Khattak
Journal:  Int Ophthalmol       Date:  2017-12-22       Impact factor: 2.031

4.  A comparative study: deep anterior lamellar keratoplasty for corneal dystrophies using two different donor stromal tissues.

Authors:  Yusuf Koçluk; Emine Alyamaç Sukgen
Journal:  Int Ophthalmol       Date:  2017-09-22       Impact factor: 2.031

5.  Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.

Authors:  Laszlo Modis; Ziad Hassan; Eszter Szalai; Zsuzsanna Flaskó; Andras Berta; Gabor Nemeth
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

Review 6.  Intraocular Pressure Measurement after Penetrating Keratoplasty.

Authors:  Otilia-Maria Dumitrescu; Sinziana Istrate; Mioara-Laura Macovei; Alina Gabriela Gheorghe
Journal:  Diagnostics (Basel)       Date:  2022-01-19

7.  Recurrent keratoconus in a corneal graft after deep anterior lamellar keratoplasty.

Authors:  Sepehr Feizi; Mohammad-Ali Javadi; Mozhgan Rezaei Kanavi
Journal:  J Ophthalmic Vis Res       Date:  2012-10

Review 8.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

9.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer.

Authors:  Vanathi Murugesan; Ravi Bypareddy; Mahesh Kumar; Dada Tanuj; Panda Anita
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

10.  Corneal Biomechanical Properties of Keratoconic Eyes Following Penetrating Keratoplasty.

Authors:  Hamidu Gobeka; Özlem Barut Selver; Melis Palamar Onay; Sait Eğrilmez; Ayşe Yağcı
Journal:  Turk J Ophthalmol       Date:  2018-09-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.