Literature DB >> 7290019

Generalized image combinations in dual KVP digital radiography.

L A Lehmann, R E Alvarez, A Macovski, W R Brody, N J Pelc, S J Riederer, A L Hall.   

Abstract

Dual energy basis decomposition techniques apply to single projection radiographic imaging. The high and low energy images are non-linearly transformed to generate two energy-independent images characterizing the integrated Compton/photoelectric attenuation components. Characteristic linear combinations of these two basis images identify unknown materials, cancel known materials, and generate synthesized monoenergetic images. The problems of intervening materials and material displacement are solved in general for a wide class of clinical imaging tasks. The basis projection angle identifies one from a family of energy selective imaging tasks, and such performance measures as the contrast enhancement factor (CEF) and signal to noise ratio (SNR) are expressed as functions of this angle. Algorithms for the decomposition of high and low energy measurements are compared and experimental images are included.

Entities:  

Mesh:

Year:  1981        PMID: 7290019     DOI: 10.1118/1.595025

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  85 in total

1.  Lung field segmenting in dual-energy subtraction chest X-ray images.

Authors:  Robert E Alvarez
Journal:  J Digit Imaging       Date:  2004-03       Impact factor: 4.056

2.  Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality.

Authors:  Lifeng Yu; Jodie A Christner; Shuai Leng; Jia Wang; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Noise and Bias Properties of Monoenergetic Images from DECT used for Attenuation Correction with PET/CT and SPECT/CT.

Authors:  Ting Xia; Adam M Alessio; Paul E Kinahan
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-05-22

4.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

5.  Spectral response model for a multibin photon-counting spectral computed tomography detector and its applications.

Authors:  Xuejin Liu; Mats Persson; Hans Bornefalk; Staffan Karlsson; Cheng Xu; Mats Danielsson; Ben Huber
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-11

6.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

7.  A comparison of two dual-energy X-ray absorptiometry systems for spinal bone mineral measurement.

Authors:  K C Lai; M M Goodsitt; R Murano; C H Chesnut
Journal:  Calcif Tissue Int       Date:  1992-03       Impact factor: 4.333

8.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.

Authors:  A N Primak; J C Ramirez Giraldo; X Liu; L Yu; C H McCollough
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

9.  Dual energy CT for attenuation correction with PET/CT.

Authors:  Ting Xia; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

10.  Changes in measured size of atherosclerotic plaque calcifications in dual-energy CT of ex vivo carotid endarterectomy specimens: effect of monochromatic keV image reconstructions.

Authors:  Lorenzo Mannelli; Lee M Mitsumori; Marina Ferguson; Dongxiang Xu; Baocheng Chu; Kelley R Branch; William P Shuman; Chun Yuan
Journal:  Eur Radiol       Date:  2012-08-21       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.