Literature DB >> 30039467

[Endoprosthetic wear analysis using virtual CAD-based radiographs].

M Haversath1, S Klebingat2, M Jäger3.   

Abstract

The articulating parts of an endoprosthetic joint are subjected to constant wear, which results in loss of material. In peri-implant tissue, the wear debris particles cause aseptic inflammation with osteolysis and aseptic loosening. Due to the associated bone resorption-which can be considerable-"particle disease" represents a significant challenge for orthopedic surgeons. Continuous improvements in the material properties of polyethylene during the past decades have resulted in reduced wear and longer implant survival times. To evaluate wear properties in polyethylene liners after total hip arthroplasty in vivo, different graphics-based, semiautomatic software packages were developed to measure femoral head penetration in radiographic image series. However, the reduced wear properties of the new materials rendered their precise analysis and evaluation more difficult, and no software was able to reproduce the accuracy of the complex and expensive radiostereometric analysis first described by Selvik in 1974, which is still viewed as the gold standard. The aim of this study is to describe the validation of a novel and accurate method to analyze polyethylene wear in vivo using virtual computer-aided detection/diagnosis (CAD)-based radiographic images. Furthermore, its use is presented based on the first 5‑year follow-up results of a multicenter approach evaluating the impact of vitamin E-blended polyethylene in cementless total hip replacement. Our data support the high accuracy of CAD-based virtual evaluation.

Entities:  

Keywords:  Computer-aided design; Digital radiography; Hip joint; Joint prosthesis; Radiographic image

Mesh:

Substances:

Year:  2018        PMID: 30039467     DOI: 10.1007/s00132-018-3602-z

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  10 in total

Review 1.  Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.

Authors:  G Selvik
Journal:  Acta Orthop Scand Suppl       Date:  1989

2.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

3.  The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene.

Authors:  Daniel M Estok; Charles R Bragdon; Gordon R Plank; Anna Huang; Orhun K Muratoglu; William H Harris
Journal:  J Arthroplasty       Date:  2005-02       Impact factor: 4.757

4.  The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.

Authors:  S Glyn-Jones; P McLardy-Smith; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-05

5.  Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

Authors:  Stuart A Callary; Lucian B Solomon; Oksana T Holubowycz; David G Campbell; Donald W Howie
Journal:  J Orthop Res       Date:  2016-07-12       Impact factor: 3.494

6.  Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks.

Authors:  Shaoqing Ren; Kaiming He; Ross Girshick; Jian Sun
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2016-06-06       Impact factor: 6.226

Review 7.  Vitamin E-stabilized UHMWPE for total joint implants: a review.

Authors:  Pierangiola Bracco; Ebru Oral
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

8.  In vivo hip joint loads during three methods of walking with forearm crutches.

Authors:  Philipp Damm; Verena Schwachmeyer; Joern Dymke; Alwina Bender; Georg Bergmann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-05-02       Impact factor: 2.063

9.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

10.  A multicenter approach evaluating the impact of vitamin e-blended polyethylene in cementless total hip replacement.

Authors:  Marcus Jäger; Andrea van Wasen; Sebastian Warwas; Stefan Landgraeber; Marcel Haversath; Vitas Group
Journal:  Orthop Rev (Pavia)       Date:  2014-04-22
  10 in total
  1 in total

1.  Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up.

Authors:  Josef Baghdadi; Shareef Alkhateeb; Alexander Roth; Marcus Jäger
Journal:  Arch Orthop Trauma Surg       Date:  2022-04-10       Impact factor: 3.067

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.