Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

Stuart A Callary1,2, Lucian B Solomon1,2, Oksana T Holubowycz1, David G Campbell3, Donald W Howie1,2.   

Abstract

A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs.
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:988-996, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  accuracy; polyethylene wear; radiostereometric analysis; total hip arthroplasty

Mesh:

Year:  2016        PMID: 27357247     DOI: 10.1002/jor.23356

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  5 in total

Review 1.  [Endoprosthetic wear analysis using virtual CAD-based radiographs].

Authors:  M Haversath; S Klebingat; M Jäger
Journal:  Orthopade       Date:  2018-10       Impact factor: 1.087

2.  Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up.

Authors:  Josef Baghdadi; Shareef Alkhateeb; Alexander Roth; Marcus Jäger
Journal:  Arch Orthop Trauma Surg       Date:  2022-04-10       Impact factor: 3.067

3.  Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study.

Authors:  David G Campbell; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2022-03-01       Impact factor: 4.755

4.  Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA.

Authors:  D Dammerer; A Keiler; D Putzer; F Lenze; M Liebensteiner; M Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-04       Impact factor: 3.067

5.  Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty.

Authors:  Alberto V Carli; Anay R Patel; Michael B Cross; David J Mayman; Kaitlin M Carroll; Paul M Pellicci; Seth A Jerabek
Journal:  SICOT J       Date:  2020-05-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.