Literature DB >> 29943720

Development of Loop-Mediated Isothermal Amplification-Based Lateral Flow Device Method for the Detection of Malaria.

Prudhvi Chand Mallepaddi1,2, Meng-Yee Lai3, Sudhakar Podha1, Choo-Huck Ooi4, Jonathan Wee-Kent Liew3, Rathnagiri Polavarapu1,2, Yee-Ling Lau3.   

Abstract

The present study aims to develop a method for rapid diagnosis of malaria using loop-mediated isothermal amplification (LAMP) combined with a lateral flow device (LFD). By adding the biotin-labeled and fluorescein amidite-labeled loop primers to the LAMP reaction solution, the end product can be visualized on a LFD. The entire procedure takes approximately 42 minutes to complete, LAMP assay exhibited high sensitivity, as the detection limit was 0.01 pg/μL for all five Plasmodium species. It was demonstrated that all Plasmodium knowlesi (N = 90) and Plasmodium vivax (N = 56) were positively amplified by LAMP-LFD assay, whereas healthy donor samples (N = 8) were negative. However, not all mixed infections were positive, and other infected nonmalaria samples were negative. Loop-mediated isothermal amplification-LFD represents a robust approach with potential suitability for use in resource-constrained laboratories. We believe that LAMP-LFD has a potential to be developed as point-of-care diagnostic tool in future.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29943720      PMCID: PMC6169156          DOI: 10.4269/ajtmh.18-0177

Source DB:  PubMed          Journal:  Am J Trop Med Hyg        ISSN: 0002-9637            Impact factor:   2.345


  16 in total

1.  Loop-mediated isothermal amplification of DNA.

Authors:  T Notomi; H Okayama; H Masubuchi; T Yonekawa; K Watanabe; N Amino; T Hase
Journal:  Nucleic Acids Res       Date:  2000-06-15       Impact factor: 16.971

2.  Accelerated reaction by loop-mediated isothermal amplification using loop primers.

Authors:  K Nagamine; T Hase; T Notomi
Journal:  Mol Cell Probes       Date:  2002-06       Impact factor: 2.365

3.  A SIMPLE PHENYLALANINE METHOD FOR DETECTING PHENYLKETONURIA IN LARGE POPULATIONS OF NEWBORN INFANTS.

Authors:  R GUTHRIE; A SUSI
Journal:  Pediatrics       Date:  1963-09       Impact factor: 7.124

4.  Detection and species identification of malaria parasites by isothermal tHDA amplification directly from human blood without sample preparation.

Authors:  Ying Li; Nirbhay Kumar; Anusha Gopalakrishnan; Christine Ginocchio; Ryhana Manji; Maureen Bythrow; Bertrand Lemieux; Huimin Kong
Journal:  J Mol Diagn       Date:  2013-06-22       Impact factor: 5.568

5.  Loop-mediated isothermal amplification assay for rapid diagnosis of malaria infections in an area of endemicity in Thailand.

Authors:  Jetsumon Sattabongkot; Takafumi Tsuboi; Eun-Taek Han; Sirasate Bantuchai; Sureemas Buates
Journal:  J Clin Microbiol       Date:  2014-02-26       Impact factor: 5.948

6.  Application of loop-mediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivax.

Authors:  Suganya Yongkiettrakul; Wansadaj Jaroenram; Narong Arunrut; Wanwisa Chareanchim; Supicha Pannengpetch; Rungkarn Suebsing; Wansika Kiatpathomchai; Wichai Pornthanakasem; Yongyuth Yuthavong; Darin Kongkasuriyachai
Journal:  Parasitol Int       Date:  2014-07-17       Impact factor: 2.230

7.  Detection of four Plasmodium species by genus- and species-specific loop-mediated isothermal amplification for clinical diagnosis.

Authors:  Eun-Taek Han; Risa Watanabe; Jetsumon Sattabongkot; Benjawan Khuntirat; Jeeraphat Sirichaisinthop; Hideyuki Iriko; Ling Jin; Satoru Takeo; Takafumi Tsuboi
Journal:  J Clin Microbiol       Date:  2007-06-13       Impact factor: 5.948

8.  Loop-Mediated Isothermal Amplification Label-Based Gold Nanoparticles Lateral Flow Biosensor for Detection of Enterococcus faecalis and Staphylococcus aureus.

Authors:  Yi Wang; Hui Li; Yan Wang; Lu Zhang; Jianguo Xu; Changyun Ye
Journal:  Front Microbiol       Date:  2017-02-10       Impact factor: 5.640

9.  Loop-Mediated Isothermal Amplification Assay for Identification of Five Human Plasmodium Species in Malaysia.

Authors:  Yee-Ling Lau; Meng-Yee Lai; Mun-Yik Fong; Jenarun Jelip; Rohela Mahmud
Journal:  Am J Trop Med Hyg       Date:  2015-11-23       Impact factor: 2.345

10.  A novel diagnostic method for malaria using loop-mediated isothermal amplification (LAMP) and MinION™ nanopore sequencer.

Authors:  Kazuo Imai; Norihito Tarumoto; Kazuhisa Misawa; Lucky Ronald Runtuwene; Jun Sakai; Kyoko Hayashida; Yuki Eshita; Ryuichiro Maeda; Josef Tuda; Takashi Murakami; Shigefumi Maesaki; Yutaka Suzuki; Junya Yamagishi; Takuya Maeda
Journal:  BMC Infect Dis       Date:  2017-09-13       Impact factor: 3.090

View more
  8 in total

1.  Plasmodium knowlesi detection methods for human infections-Diagnosis and surveillance.

Authors:  Matthew J Grigg; Inke N Lubis; Kevin K A Tetteh; Bridget E Barber; Timothy William; Giri S Rajahram; Angelica F Tan; Colin J Sutherland; Rintis Noviyanti; Chris J Drakeley; Sumudu Britton; Nicholas M Anstey
Journal:  Adv Parasitol       Date:  2021-09-17       Impact factor: 3.125

Review 2.  Plasmodium knowlesi: the game changer for malaria eradication.

Authors:  Wenn-Chyau Lee; Fei Wen Cheong; Amirah Amir; Meng Yee Lai; Jia Hui Tan; Wei Kit Phang; Shahhaziq Shahari; Yee-Ling Lau
Journal:  Malar J       Date:  2022-05-03       Impact factor: 3.469

3.  Development and evaluation of LAMP-coupled lateral flow device for the detection of MAP in livestock at point of care resource-limited areas.

Authors:  Rudrama Devi Punati; Prudhvi Chand Mallepaddi; Revathi Poonati; Soumendra Nath Maity; Jagdip Singh Sohal; Kavi Kishor B Polavarapu; Rathnagiri Polavarapu
Journal:  Braz J Microbiol       Date:  2019-09-20       Impact factor: 2.476

4.  Poor Diagnostic Performance of a Species-Specific Loop-Mediated Isothermal Amplification (LAMP) Platform for Malaria.

Authors:  Hans Kollenda; Ralf Matthias Hagen; Miriam Hanke; Sandra Rojak; Rebecca Hinz; Lars Wassill; Sven Poppert; Egbert Tannich; Hagen Frickmann
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2018-09-28

5.  Comparative study of the loop-mediated isothermal amplification method and the QIAGEN therascreen PCR kit for the detection of EGFR mutations in non-small cell lung cancer.

Authors:  Yuichi Saito; Nobumasa Takahashi; Atsuka Matsui; Satoru Michiyuki; Yoshikane Yamauchi; Yoshihiko Shimizu; Eishin Hoshi; Yukinori Sakao; Masafumi Kawamura
Journal:  J Thorac Dis       Date:  2021-02       Impact factor: 2.895

Review 6.  Lateral flow assays for viruses diagnosis: Up-to-date technology and future prospects.

Authors:  Bahar Ince; Mustafa Kemal Sezgintürk
Journal:  Trends Analyt Chem       Date:  2022-07-05       Impact factor: 14.908

7.  Rapid diagnosis of Plasmodium falciparum malaria using a point-of-care loop-mediated isothermal amplification device.

Authors:  Madhu Puri; Harsimran Kaur Brar; Evanka Madan; Rajesh Srinivasan; Kapil Rawat; Sai Siva Gorthi; Geeta Kumari; Raj Sah; Sashi Bhusan Ojha; Subhendu Panigrahi; Gunanidhi Dhangadamajhi; Rohini Muthuswami; Shailja Singh; Rentala Madhubala
Journal:  Front Cell Infect Microbiol       Date:  2022-08-19       Impact factor: 6.073

8.  Advanced Multiplex Loop Mediated Isothermal Amplification (mLAMP) Combined with Lateral Flow Detection (LFD) for Rapid Detection of Two Prevalent Malaria Species in India and Melting Curve Analysis.

Authors:  Supriya Sharma; Sandeep Kumar; Md Zohaib Ahmed; Nitin Bhardwaj; Jaskirat Singh; Sarita Kumari; Deepali Savargaonkar; Anupkumar R Anvikar; Jyoti Das
Journal:  Diagnostics (Basel)       Date:  2021-12-24
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.