Literature DB >> 25038579

Application of loop-mediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivax.

Suganya Yongkiettrakul1, Wansadaj Jaroenram2, Narong Arunrut3, Wanwisa Chareanchim1, Supicha Pannengpetch1, Rungkarn Suebsing3, Wansika Kiatpathomchai3, Wichai Pornthanakasem1, Yongyuth Yuthavong1, Darin Kongkasuriyachai4.   

Abstract

Malaria is largely a preventable and curable disease. However, a delay or an inappropriate treatment can result in serious adverse outcomes for patient. Rapid, simple and cost-effective diagnostic tests that can be easily adapted and rapidly scaled-up at the field or community levels are needed. In this study, accelerated detection methods for the Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) dihydrofolate reductase-thymidylate synthase were developed based on the loop-mediated isothermal amplification (LAMP) method. The developed methods included the use of species-specific biotinylated primers to amplify LAMP amplicons, which were then hybridized to specific FITC-labeled DNA probes and visualized on a chromatographic lateral flow dipstick (LFD). The total LAMP-LFD assay time was approximately 1.5h. The LAMP-LFD assays showed similar detection limit to conventional PCR assay when performed on plasmid DNA carrying the malaria dhfr-ts genes. The LAMP-LFD showed 10 folds higher detection limit than PCR when performed on genomic DNA samples from Pf and Pv parasites. The dhfr-ts LAMP-LFD assays also have the advantages of reduced assay time and easy format for interpretation of results.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Lateral flow dipstick; Loop-mediated isothermal amplification; Plasmodium falciparum; Plasmodium vivax

Mesh:

Substances:

Year:  2014        PMID: 25038579     DOI: 10.1016/j.parint.2014.06.004

Source DB:  PubMed          Journal:  Parasitol Int        ISSN: 1383-5769            Impact factor:   2.230


  20 in total

1.  Development of Loop-Mediated Isothermal Amplification-Based Lateral Flow Device Method for the Detection of Malaria.

Authors:  Prudhvi Chand Mallepaddi; Meng-Yee Lai; Sudhakar Podha; Choo-Huck Ooi; Jonathan Wee-Kent Liew; Rathnagiri Polavarapu; Yee-Ling Lau
Journal:  Am J Trop Med Hyg       Date:  2018-06-21       Impact factor: 2.345

2.  Detection of nucleic acids and elimination of carryover contamination by using loop-mediated isothermal amplification and antarctic thermal sensitive uracil-DNA-glycosylase in a lateral flow biosensor: application to the detection of Streptococcus pneumoniae.

Authors:  Yi Wang; Yan Wang; Dongxun Li; Jianguo Xu; Changyun Ye
Journal:  Mikrochim Acta       Date:  2018-03-07       Impact factor: 5.833

3.  Development of a filtration-based LAMP-LFA method as sensitive and rapid detection of E. coli O157:H7.

Authors:  Jin-Hee Kim; Se-Wook Oh
Journal:  J Food Sci Technol       Date:  2019-04-01       Impact factor: 2.701

4.  Coupling Sensitive Nucleic Acid Amplification with Commercial Pregnancy Test Strips.

Authors:  Yan Du; Arti Pothukuchy; Jimmy D Gollihar; Armin Nourani; Bingling Li; Andrew D Ellington
Journal:  Angew Chem Int Ed Engl       Date:  2016-12-19       Impact factor: 15.336

Review 5.  An Update on Malaria Rapid Diagnostic Tests.

Authors:  Avinash N Mukkala; Jason Kwan; Rachel Lau; David Harris; Dylan Kain; Andrea K Boggild
Journal:  Curr Infect Dis Rep       Date:  2018-10-23       Impact factor: 3.725

6.  Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella.

Authors:  Liang Wang; Guofu Chen; Chunyun Zhang; Yuanyuan Wang; Rui Sun
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-11       Impact factor: 4.223

7.  Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay.

Authors:  Agathe Nkouawa; Yasuhito Sako; Munehiro Okamoto; Akira Ito
Journal:  Am J Trop Med Hyg       Date:  2016-04-04       Impact factor: 2.345

8.  A simple, high-throughput, colourimetric, field applicable loop-mediated isothermal amplification (HtLAMP) assay for malaria elimination.

Authors:  Sumudu Britton; Qin Cheng; Colin J Sutherland; James S McCarthy
Journal:  Malar J       Date:  2015-08-28       Impact factor: 2.979

9.  Sensitive Detection of Plasmodium vivax Using a High-Throughput, Colourimetric Loop Mediated Isothermal Amplification (HtLAMP) Platform: A Potential Novel Tool for Malaria Elimination.

Authors:  Sumudu Britton; Qin Cheng; Matthew J Grigg; Catherine B Poole; Cielo Pasay; Timothy William; Kimberley Fornace; Nicholas M Anstey; Colin J Sutherland; Chris Drakeley; James S McCarthy
Journal:  PLoS Negl Trop Dis       Date:  2016-02-12

10.  Development of a fluorescent probe-based recombinase polymerase amplification assay for rapid detection of Orf virus.

Authors:  Yang Yang; Xiaodong Qin; Guangxiang Wang; Yuen Zhang; Youjun Shang; Zhidong Zhang
Journal:  Virol J       Date:  2015-12-02       Impact factor: 4.099