Literature DB >> 29854881

Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

Shoaleh Shahidi1, Barbad Zamiri2, Masoud Abolvardi3, Marzieh Akhlaghian4, Maryam Paknahad5.   

Abstract

STATEMENT OF THE PROBLEM: Accurate measurement of the available bone height is an essential step in the pre-surgical phase of dental implantation. Panoramic radiography is a unique technique in the pre-surgical phase of dental implantations because of its low cost, relatively low-dose, and availability.
PURPOSE: This article aimed to assess the reliability of dental panoramic radiographs in the accurate measurement of the vertical bone height with respect to the horizontal location of the alveolar crest. MATERIALS AND
METHOD: 132 cone-beam computed tomography (CBCT) of the edentulous mandibular molar area and dental panoramic radiograph of 508 patients were selected. Exclusion criteria were bone abnormalities and detectable ideal information on each modality. The alveolar ridge morphology was categorized into 7 types according to the relative horizontal location of the alveolar crest to the mandibular canal based on CBCT findings. The available bone height (ABH) was defined as the distance between the upper border of the mandibular canal and alveolar crest. One oral radiologist and one oral surgeon measured the available bone height twice on each modality with a 7-dayinterval.
RESULTS: We found a significant correlation between dental panoramic radiographs and cone-beam computed tomography values (ICC=0.992, p< 0.001). A positive correlation between the horizontal distance of the alveolar crest to the mandibular canal and measured differences between two radiographic modalities had been found (r=0.755, p< 0.001). For each single unit of increase in the horizontal distance of the alveolar crest to the mandibular canal, dental panoramic radiographs showed 0.87 unit of overestimation (p< 0.001).
CONCLUSION: Dental panoramic radiographs can be employed safely in the pre-surgical phase of dental implantation in posterior alveolus of mandible, especially in routine and simple cases.

Entities:  

Keywords:  Available bone height; Cone-beam computed tomography ; Dental implant ; Dental panoramic radiograph

Year:  2018        PMID: 29854881      PMCID: PMC5960739     

Source DB:  PubMed          Journal:  J Dent (Shiraz)        ISSN: 2345-6418


Introduction

Replacing missing teeth has always been an important issue in dentistry. There are different choices to achieve this goal such as removable partial denture, fixed partial denture, and dental implants.[1] Among them, dental implants have the highest long-term success rate reported to be up to 96.4%.[2-4] This high success rate contributes to improvements in the surface and design of dental implants,5 different surgical approaches,[4-6] and also advancements in radiologic techniques.[7-10] Accurate measurement of the alveolar bone height and thickness, and a safe margin from anatomic structures such as maxillary sinus, mental foramen, and inferior alveolar nerve canal are important factors in pre-surgical planning phase of dental implant placing.[11] There are different methods of radiographic imaging to assess the candidate area of implant inserting including peri-apical,[12] dental panoramic radiography (DPR),[12-16] lateral cephalometry,[17] conventional tomography,[8,12] computed tomography (CT),[8,12,18] and cone-beam computed tomography (CBCT).[5,8,19] Although the advanced imaging techniques (CT and CBCT) have many advantages such as cross-sectional information and multi-dimensional views,[20] DPR keeps its values in pre-surgical planning phase of dental implantation.[8,20-24] DPR displays the whole body of the mandible, most parts of the maxilla, and their internal structures such as mandibular canal and maxillary sinus on a single projection.[25] The length and the mesiodistal angulation of a dental implant are usually determined in DPR even though it has some limitations such as ghost image of the vertebra in the anterior part, positioning errors and magnification.[26] Moreover, DPR is easily available and is relatively inexpensive. Regarding its advantages, DPR is considered as the most common single radiographic examination used in dental implant treatment planning.[14] The comparison of DPR with other non-tomographic techniques started in 2006 by Wakoh and colleagues who assessed the reliability of DPR and standardized peri-apical radiographs.[27] Their study suggested that standardized peri-apical radiographs were more accurate than DPR in linear distance measurement for dental implantation. Furthermore, a comparison between DPR and lateral cephalometry was done in 2007 by Beltrão and colleagues,[17] who concluded that lateral cephalographs could be a useful guide for maxillary dental implant-based reconstruction.[17] Later, CBCT as a technique of choice for precise measurements, even on normal structures and jaw pathoses, was used in the field of dental implantation.[28-31] While some studies introduced DPR as a reliable technique for measurements of available bone height for dental implantation, [5,8,20-21,32-33] others claimed that DPR could not provide reliable information and might lead to the failure of treatment. [5,19,22-23,34-36] Therefore, we aimed to determine the reliability of DPR as a two-dimensional imaging method in measuring the precise vertical bone height by evaluating the horizontal location of the alveolar crest.

Materials and Method

Data acquisition

From the CBCT and DPR images of 508 (246 men, 262 women) candidates for dental implants in a private Oral and Maxillofacial Radiology Clinic in Shiraz, Southern Iran, from Feb. 2013 to Feb. 2014, 144 images of edentulous mandibular molar areas were recruited retrospectively. The exclusion criteria comprised both patient and image related factors. The patient related factors involved any pathosis in the area of measurement, recent extraction sockets retained root, mental foramen on the level of the alveolar crest, history of confirmed osteoporosis, and any other uncontrolled systemic diseases. In the image related category, all images with undetectable superior cortex of the mandibular canal or indistinct crestal cortex of the alveolar process in DPR or those lacking the ideal quality in the CBCT were excluded. DPRs in this study were taken with respect to the optimum situations, which were provided by the manufacturer. One machine for DPR (Planmeca cc-proline, Finland) and one CBCT machine (NewTom VGi) were used. A standardized protocol of the NewTom for the extended (12*15 cm) field of view with 0.3mm slice thickness and 26.9 seconds acquisition time was used. All DPRs were taken using Konica CR receptor image plate (12×10 inch) and were displayed on the Fuji Computed Radiography system (Fuji Computed Radiography 5000R, Fuji Photo Film Co. Ltd., Dusseldorf, Germany).

Alveolar bone shape classification

The alveolar ridge morphology was categorized into seven types according to the relative horizontal location of the peak of the alveolar crest to the mandibular canal on reformatted cross-sectional CBCT images (Figure 1).
Figure1

Sevent types of location of the peak point of the alveolar crest according to the mandibular canal. B and L, peak point of the alvoalr crest; P: Vertical line passing through the center of the mandibular canal and perpendicular ;eedcular to the lower border of earch imaging. Type N: X=0 Type B1: -2mm≤X≤0 Type B2: -4mm≤ X≤-2mm Type B3: X< -4mm Type L1: 0 +4mm

Sevent types of location of the peak point of the alveolar crest according to the mandibular canal. B and L, peak point of the alvoalr crest; P: Vertical line passing through the center of the mandibular canal and perpendicular ;eedcular to the lower border of earch imaging. Type N: X=0 Type B1: -2mm≤X≤0 Type B2: -4mm≤ X≤-2mm Type B3: X< -4mm Type L1: 0 +4mm Type N: the peak point of the alveolar crest was positioned in the center compared with the vertical line passing through the center of the mandibular canal and perpendicular to the lower border of each image. Type B1: the peak point of the alveolar crest was positioned in the buccal side and the distance from the vertical line was less than 2mm. Type B2: the peak point of the alveolar crest was positioned in the buccal side and the distance from the vertical line was greater than 2mm and less than 4mm. Type B3: the peak point of the alveolar crest was positioned in the buccal side and the distance from the vertical line was greater than 4mm. Type L1: the peak point of the alveolar crest was positioned in the lingual side and the distance from the vertical line was less than 2mm. Type L2: the peak point of the alveolar crest was positioned in the lingual side and the distance from the vertical line was greater than 2mm and less than 4mm. Type L3: the peak point of the alveolar crest was positioned in the lingual side and the distance from the vertical line was greater than 4mm.

Measurement

In order to match the sections in each modality, the cross-sections in CBCT were obtained perpendicular to the true horizontal plan and the DPR sections were obtained perpendicular to the lower border of each image which was parallel to the true horizontal plan in standard situations. The mesio-distal location of the first candidate site was defined to have 5mm distance from the nearest natural tooth or dental implant at the level of the alveolar crest and for the next sites, another 5mm was added to the previous distance (Figure 2).
Figure2

A DPR of a patient. b: Cropped image of Figure 2a, showing the producer of measuring the mesiodistal location of dental implant insertion site. C: alveolar crest; S: Superior border of mandibular canal; I: Inferior border of mandibular canal; LA: Long axis of the nearest tooth (or implant); R: Outer surface of the root of the nearest tooth (or implant)

A DPR of a patient. b: Cropped image of Figure 2a, showing the producer of measuring the mesiodistal location of dental implant insertion site. C: alveolar crest; S: Superior border of mandibular canal; I: Inferior border of mandibular canal; LA: Long axis of the nearest tooth (or implant); R: Outer surface of the root of the nearest tooth (or implant) The available bone height in CBCT views was defined as the distance between the line tangential to the upper border of the mandibular canal and the line tangential to the peak of the alveolar crest, which were both parallel to the lower border of reformatted cross-sectional CBCT images (Figure 3).
Figure3

The ABH in CBCT was defined as the distance bertween the line tangential to the upper border of the mandibular canal and the line tangential to the peak of the alvoelar crest, which were both parallel to the lower border of the image

The ABH in CBCT was defined as the distance bertween the line tangential to the upper border of the mandibular canal and the line tangential to the peak of the alvoelar crest, which were both parallel to the lower border of the image The available bone height in DPR was measured as follows: a line was depicted from the most superior point of the alveolar crest perpendicular to the lower border of image. Then the distance between the alveolar crest and the superior border of the mandibular canal was measured (Figure 4).
Figure4

a: A DPR of patient. b: Cropped image of Figure 4a, showing the producer of measure ABH in PDRs. C: Alveolar crest; S: Superior border of mandibular canal; I: inferior border of mandibular canal and ABH: The distance between C and S on the line which is perpendicular to the lower border of main image

a: A DPR of patient. b: Cropped image of Figure 4a, showing the producer of measure ABH in PDRs. C: Alveolar crest; S: Superior border of mandibular canal; I: inferior border of mandibular canal and ABH: The distance between C and S on the line which is perpendicular to the lower border of main image The linear measurements and the angular measurements were performed using the CBCT software (M-view TM PS [Infinitt, Seoul, republic of Korea]). The available bone height was measured twice on both imaging modalities with an interval of seven days and the differences were compared according to their types.

Statistical analysis

Data were analyzed using SPSS software, version 17.0 (SPSS, Chicago, IL). Intra-class correlation coefficient (ICC) was used to evaluate the agreement between values measured in DPR and CBCT. Pearson’s correlation(r) and linear regression were used to assess the relationship between the vertical available bone height measurements difference (∆) of the two methods (DPR and CBCT) and the horizontal distance of the alveolar crest to the center of mandibular canal.

Results

All 508 CBCT and DPR images were assessed in this study, consisting of 109 cases for type L3, 92 cases for type L2, 83 cases for type L1, 13 cases for type N, 67 cases for type B1, 84 cases for type B2, and 60 cases for type B3 (Figure 5).
Figure5

Descriptive characteristics of the studied cases (N=132)

Descriptive characteristics of the studied cases (N=132) Of the selected 144 cases, 12 cases were excluded because of having recent extraction sockets or being a known case of osteoporosis. The other 132 cases were recruited in the study (response rate=91.6%). Of these 132 cases, the type L3 had the most frequent with 43 cases (32.57%) followed by type L2 (n=28, 21.21%), and type N (n=2, 1.51%) was the rarest and least frequent (Table 1).
Table 1

Descriptive characteristics of the studied cases (n=132)

Alveolar bone shape classificationFrequency (%)
L343(32.57)
L228(21.21)
L113(9.84)
N2(1.51)
B113(9.84)
B219(14.40)
B314(10.6)
Total132(100)
Descriptive characteristics of the studied cases (n=132) Intra-class correlation coefficient showed a significant correlation between DPR and CBCT values (ICC=0.992, pp< 0.001). By dividing the cases into three major categories (buccal, lingual, and neutral) the intra-class correlation coefficient again demonstrated a strong correlation between DPR and CBCT values (in buccal types: ICC=0.998, pp< 0.001; and in lingual types: ICC= 0.993, pp< 0.001, Table 2)
Table 2

The correlation between values of DPR and CBCT (N=132)

FrequencyIntra-class correlation P Value
Buccal types460.998<0.001
Lingual types840.993<0.001
Neutral types2
Total1320.992<0.001
The correlation between values of DPR and CBCT (N=132) There was a positive correlation between the horizontal distance of the alveolar crest to the center of mandibular canal and ∆ (r= 0.755, pp< 0.001). Regression analysis showed that for each single-unit increase in the horizontal distance of the alveolar crest to the center of mandibular canal, the DPR values were 0.87 unit more than CBCT ones (pp< 0.001, Table 3).
Table 3

The relationship between horizontal distance and the amount of ∆

rβSE P Value
0.7550.87.008<0.001

∆: (value of DPR -value of CBCT); SE: standard error

The relationship between horizontal distance and the amount of ∆ ∆: (value of DPR -value of CBCT); SE: standard error The mean (median) error of DPR in detecting the ABH for edentulous ridges in posterior of mandible was 0.21mm±0.42mm (0.20mm).

Discussion

In the present study, we assessed the reliability of DPR in measuring the available bone height in comparison with CBCT. Meanwhile, the effect of horizontal location of the alveolar crest related to the center of mandibular canal on this vertical height had been appraised. Our findings showed there was a strong and linear relationship between the values measured on each modality. The mean error of DPR in detecting the available bone height for edentulous ridges in posterior of mandible was 0.21mm±0.42mm, which did not make a serious confusion in pre-surgical planning of dental implant therapy, especially in routine cases. This mean error in DPR (0.21mm±0.42mm) had a regular distribution in a way that the values on DPR were smaller than the real values on CBCT when the alveolar crest was located buccally compared with the mandibular canal. Moreover, these values get closer to the real as the alveolar crest displays lingually (N types) and finally, when the alveolar crest was located more than 4mm lingual to the mandibular canal, the values on DPR were more than true ABH. An important issue is the image production method in DPR machines in which the X-ray beam has a negative degree of projection (-4 to -7degrees) to eliminate the image of the skull base in the radiographs. It means that the DPR plane is not exactly coinciding with the true vertical plane. This minor difference in vertical planes results in wider and upper-located images of the objects in the lingual aspect of the image layer. It could be the reason for overestimation in lingual types. Moreover, of 132 enrolled cases, only two showed the alveolar crest exactly on the top of the mandibular canal. So that the alveolar crest was displaced buccally or lingually after tooth extraction quiet frequently. This displacement was more likely towards the lingual side in the posterior segment of the mandible, which is compatible with clinical observations. Contrasting results with other studies could be attributed to the sample size and/or the inclusion and exclusion criteria. In our study, from 508 available CBCT and DPR images, we selected only 144cases based on our image related exclusion factors. In the next step, 12 cases of this new sample population were excluded due to patient-related factors. Although these strict inclusion and exclusion criteria decreased the number of available cases, the remaining cases were acceptable for the current investigation since they were large enough to be statistically meaningful. In 1994, a comparison between diagnostic value of DPR and CBCT was performed by Reedy and colleagues.[37] They concluded that the values of DPR were significantly underestimated. However, in our study we found that DPR had some degree of overestimation especially when the alveolar crest was placed more than 4mm lingual to the mandibular canal. The difference between our study and the mentioned one might be due to different sample sizes. In the mentioned study, only one human mandible was used with ten sites for measurements while in our study 132 cases had been assessed. This large number of samples could neutralize the effect of inter-case differences. Therefore, the results of our study seemed to be more reliable in terms of sample size and consequently it could have application that is more clinical. The impact of observation error in radiologic studies could not be ignored. The expertise and number of observers, the agreement between them, and the frequency and interval of measurement by each observer are all important factors in reducing the error of human involved measurements. Bennemann and colleagues[19] observed that three groups of people involved in dentistry (oral surgeons, orthodontists and dental student) did not have any dissension in measuring the mini-screw position between the DPR and CBCT images. Although in our study the results showed an acceptable precision of DPR compared with CBCT, the difference between the values of DPR and CBCT were small. The main difference between our study and the mentioned study (in spite of other possible facts such as different study population, and so on) was most probably the difference in observers. The dental students used in the mentioned study do not seem to be expert enough for detecting the precise location of dental implants concerning their inadequate clinical experience. Furthermore, single measurement of each modality without any repeat could lead to errors. In our study, two expert professors in dental implantology team (one oral radiologist and one oral surgeon) measured each modality twice with 7-day intervals. This method could reduce the inter-examiner error and the 7-day interval could decrease or eliminate the effect of recall bias in measurements. Regarding these attempts, the values yielded by our study might be considered more accurate. The area surveyed could be another important factor in proposing a strict guideline in such investigations. Hu and colleagues[5] assessed the reliability of both DPR and CBCT modalities in human cadavers. They concluded that DPR was a safe technique for measurements in mandible, but CBCT was recommended for maxillary dental implants especially in bucco-lingual measurements. These data were similar to our results, which show that although the DPR values had a mean error (0.21 mm±0.42mm); they could be used safely for pre-surgical phase of dental implant therapy in posterior segments of the mandible. Since in our investigation we had no measurement on the maxillary bone, we could not confirm or reject these results, and it seems that more investigations on maxillary measurements are necessary. The method of categorizing the edentulous ridges is also an important issue. In an almost similar study to ours, Lee and colleagues[18] investigated the effects of the location of alveolar crest on the vertical bone height in DPR. They categorized the horizontal distance to four types including three lingual types and one type for both buccal and neutral positions. They concluded that the horizontal location of alveolar crest influenced the vertical bone height on DPR. The vertical bone height was overestimated especially when the buccal cortex of bone had been resorbed. In our study, we defined seven types for the horizontal location of the alveolar crest related to the mandibular canal in order to differentiate between buccal and lingual types more efficiently. Our results related to the lingual part were same as the mentioned study. We found that for every one millimeter of transforming of alveolar crest to lingual side, the values of DPR showed 0.87mm over-estimation. Nevertheless, the other part of our study, which was not included in any other similar study, showed that the available bone height in DPR was underestimated in buccal types. Therefore, we could realize that in the areas showing under-estimation potential of DPR for measurement of available bone height in posterior parts of mandible, the crestal cortex would be located buccally. Therefore, our categorization might be more accurate. This study was limited to measurements in posterior segment of the mandible. Assessment on the maxillary bone, especially in the posterior segment is recommended for the future studies. Also further studies in premolar area of mandible, concerning its proximity to the mental foramen, are recommended.

Conclusion

DPR can be used safely in the pre-surgical phase of dental implantation in the posterior mandible especially in routine and simple cases when CBCT is not available. Considering the overestimation of DPR, when the alveolar crest is located more than 4mm lingual to the mandibular canal, this study suggests using CBCT in situations with severe alveolar resorption.
  35 in total

1.  Reliability of panoramic radiography in determination of neurosensory disturbances related to dental implant placement in posterior mandible.

Authors:  Nükhet Kütük; Zeynep Burçin Gönen; M Taha Yaşar; Ahmet Emin Demirbaş; Alper Alkan
Journal:  Implant Dent       Date:  2014-12       Impact factor: 2.454

2.  The effects of location of alveolar crest on the vertical bone heights on panoramic radiographs.

Authors:  S-M Lee; S-S Lee; K-H Huh; W-J Yi; M-S Heo; S-C Choi
Journal:  Dentomaxillofac Radiol       Date:  2011-11-24       Impact factor: 2.419

3.  Comparison of panoramic and conventional cross-sectional tomography for preoperative selection of implant size.

Authors:  Lars Schropp; Andreas Stavropoulos; Erik Gotfredsen; Ann Wenzel
Journal:  Clin Oral Implants Res       Date:  2010-11-03       Impact factor: 5.977

Review 4.  The current status of cone beam computed tomography imaging in orthodontics.

Authors:  S Kapila; R S Conley; W E Harrell
Journal:  Dentomaxillofac Radiol       Date:  2011-01       Impact factor: 2.419

5.  Evaluating miniscrew position using orthopantomograms compared to cone-beam computed tomography.

Authors:  Ruth Bennemann; Martin Baxmann; Ludger Keilig; Susanne Reimann; Bert Braumann; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2012-05-12       Impact factor: 1.938

6.  The evaluation of digital panoramic radiographs taken for implant dentistry in the daily practice.

Authors:  Jun-Beom Park
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2010-07-01

7.  Cone Beam Computed Tomography vs Multislice Computed Tomography in Computer-Aided Design/Computer-Assisted Manufacture Guided Implant Surgery Based on Three-Dimensional Optical Scanning and Stereolithographic Guides: Does Image Modality Matter?

Authors:  Gerlig Widmann; Bastian Fischer; Johannes Peter Michael Berggren; Albina Dennhardt; Peter Schullian; Bale Reto; Wolfgang Puelacher
Journal:  Int J Oral Maxillofac Implants       Date:  2016 May-Jun       Impact factor: 2.804

8.  Panoramic and tomographic implant studies: role in the diagnosis of sinus disorders.

Authors:  José-María Martínez-González; Cristina Barona-Dorado; Oscar Arias-Irimia; Natalia Martínez-Rodríguez; Manuel Fernández-Domínguez
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2010-07-01

9.  The significance of cone beam computed tomography for the visualization of anatomical variations and lesions in the maxillary sinus for patients hoping to have dental implant-supported maxillary restorations in a private dental office in Japan.

Authors:  Kazunobu Shiki; Tatsurou Tanaka; Shinji Kito; Nao Wakasugi-Sato; Shinobu Matsumoto-Takeda; Masafumi Oda; Shun Nishimura; Yasuhiro Morimoto
Journal:  Head Face Med       Date:  2014-05-28       Impact factor: 2.151

10.  Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images.

Authors:  Maria Eugenia Guerrero; Jorge Noriega; Carmen Castro; Reinhilde Jacobs
Journal:  Imaging Sci Dent       Date:  2014-06-11
View more
  3 in total

1.  Spontaneous bone regeneration after surgical extraction of a horizontally impacted mandibular third molar: a retrospective panoramic radiograph analysis.

Authors:  Eugene Kim; Mi Young Eo; Truc Thi Hoang Nguyen; Hoon Joo Yang; Hoon Myoung; Soung Min Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-01-30

Review 2.  Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review.

Authors:  Burkhard Kunzendorf; Hendrik Naujokat; Jörg Wiltfang
Journal:  Int J Implant Dent       Date:  2021-05-27

3.  Retrospective comparative clinical study for silk mat application into extraction socket.

Authors:  Ju-Won Kim; You-Young Jo; Jwa-Young Kim; Ji-Hyeon Oh; Byoung-Eun Yang; Seong-Gon Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-04-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.