Literature DB >> 23513204

Preoperative assessment of the mandibular canal in implant surgery: comparison of rotational panoramic radiography (OPG), computed tomography (CT) and cone beam computed tomography (CBCT) for preoperative assessment in implant surgery.

Laura Pertl1, Brunhilda Gashi-Cenkoglu, Jürgen Reichmann, Norbert Jakse, Christof Pertl.   

Abstract

PURPOSE: In this anatomical study, we compared the diagnostic accuracy of rotational panoramic radiography (OPG), computed tomography (CT) and cone beam computed tomography (CBCT) to the actual anatomical situation.
MATERIALS AND METHODS: Dental images were taken of 10 human cadaver heads. Thereafter, they were prepared and measured. The height of the alveolar ridge to the mandibular canal was compared with the prior images taken. The deviation from the anatomical situation was calculated for each imaging technique.
RESULTS: In the group of OPG images, there was a median of 2.3 mm distortion ranging from -0.2 to 5.7 mm in the vertical plane compared to the actual situation found during dissection. If steel balls were used during OPG, the median distortion was lowered to 0.2 mm, but the width of -1.6 to 3 mm was still quite extensive. CT images showed a mean distortion of -0.2 mm and a width of -1.5 to 1.3 mm. The mean distortion of the CBCT images was similar to the one found in CT, namely -0.3 mm with a range from -1.5 to 0.8 mm.
CONCLUSIONS: The results show that OPG using steel balls as a calibration reference seems reliable in a standard situation. In more difficult cases, modern three-dimensional techniques should be used to additionally determine available bone volume.

Entities:  

Mesh:

Year:  2013        PMID: 23513204

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  10 in total

1.  Comparison of mesiodistal space measurements of single-implant sites on panoramic and oblique images generated by cone-beam CT.

Authors:  Mustafa Alkhader; Malik Hudieb
Journal:  Surg Radiol Anat       Date:  2013-08-27       Impact factor: 1.246

2.  2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

Authors:  Wen Pei Liu; Yoshito Otake; Mahdi Azizian; Oliver J Wagner; Jonathan M Sorger; Mehran Armand; Russell H Taylor
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-12       Impact factor: 2.924

3.  Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

Authors:  Ralf Smeets; Maximilian Schöllchen; Tobias Gauer; Ghazal Aarabi; Alexandre T Assaf; Carsten Rendenbach; Benedicta Beck-Broichsitter; Jan Semmusch; Jan Sedlacik; Max Heiland; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2016-12-02       Impact factor: 2.419

4.  Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography.

Authors:  Hanadi Sabban; Mina Mahdian; Ajay Dhingra; Alan G Lurie; Aditya Tadinada
Journal:  Imaging Sci Dent       Date:  2015-06-19

5.  Distortion of digital panoramic radiographs used for implant site assessment.

Authors:  Rayyan Abdulhamid Kayal
Journal:  J Orthod Sci       Date:  2016 Oct-Dec

Review 6.  Advanced dental implant placement techniques.

Authors:  Alex M Greenberg
Journal:  J Istanb Univ Fac Dent       Date:  2017-12-02

7.  Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

Authors:  Shoaleh Shahidi; Barbad Zamiri; Masoud Abolvardi; Marzieh Akhlaghian; Maryam Paknahad
Journal:  J Dent (Shiraz)       Date:  2018-06

8.  Comparison of the Efficacy of the Panoramic and Cone Beam Computed Tomography Imaging Methods in the Surgical Planning of the Maxillary All-On-4, M-4, and V-4.

Authors:  Erim Tandogdu; Aysa Ayali; Mehmet Gagari Caymaz
Journal:  Biomed Res Int       Date:  2022-07-27       Impact factor: 3.246

Review 9.  Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review.

Authors:  Burkhard Kunzendorf; Hendrik Naujokat; Jörg Wiltfang
Journal:  Int J Implant Dent       Date:  2021-05-27

10.  Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study.

Authors:  Öznur Özalp; Hüseyin Alican Tezerişener; Burak Kocabalkan; Ulviye Şebnem Büyükkaplan; Mehmet Mustafa Özarslan; Göksel Şimşek Kaya; Mehmet Ali Altay; Alper Sindel
Journal:  Imaging Sci Dent       Date:  2018-12-20
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.