Literature DB >> 29626289

Dosimetric changes with computed tomography automatic tube-current modulation techniques.

Sofia Spampinato1,2,3, Anna Maria Gueli4,5, Pietro Milone5,6, Luigi Angelo Raffaele4,5,6.   

Abstract

The study is aimed at a verification of dose changes for a computed tomography automatic tube-current modulation (ATCM) technique. For this purpose, anthropomorphic phantom and Gafchromic® XR-QA2 films were used. Radiochromic films were cut according to the shape of two thorax regions. The ATCM algorithm is based on noise index (NI) and three exam protocols with different NI were chosen, of which one was a reference. Results were compared with dose values displayed by the console and with Poisson statistics. The information obtained with radiochromic films has been normalized with respect to the NI reference value to compare dose percentage variations. Results showed that, on average, the information reported by the CT console and calculated values coincide with measurements. The study allowed verification of the dose information reported by the CT console for an ATCM technique. Although this evaluation represents an estimate, the method can be a starting point for further studies.

Keywords:  Anthropomorphic phantom; CTDI; DLP; Noise index; Radiochromic films

Mesh:

Year:  2018        PMID: 29626289     DOI: 10.1007/s12194-018-0454-5

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  23 in total

1.  Management of patient dose and image noise in routine pediatric CT abdominal examinations.

Authors:  Francis R Verdun; D Lepori; Pascal Monnin; Jean-François Valley; Pierre Schnyder; F Gudinchet
Journal:  Eur Radiol       Date:  2004-01-13       Impact factor: 5.315

2.  Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams.

Authors:  F Di Lillo; G Mettivier; A Sarno; G Tromba; N Tomic; S Devic; P Russo
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  Comparison of different phantom designs for CT scanner automatic tube current modulation system tests.

Authors:  S Sookpeng; C J Martin; D J Gentle
Journal:  J Radiol Prot       Date:  2013-09-11       Impact factor: 1.394

4.  Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.

Authors:  O Rampado; E Garelli; S Deagostini; R Ropolo
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

5.  Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT.

Authors:  Kalpana M Kanal; Brent K Stewart; Orpheus Kolokythas; William P Shuman
Journal:  AJR Am J Roentgenol       Date:  2007-07       Impact factor: 3.959

Review 6.  Radiation dose modulation techniques in the multidetector CT era: from basics to practice.

Authors:  Chang Hyun Lee; Jin Mo Goo; Hyun Ju Ye; Sung-Joon Ye; Chang Min Park; Eun Ju Chun; Jung-Gi Im
Journal:  Radiographics       Date:  2008 Sep-Oct       Impact factor: 5.333

7.  Computed tomography dose measurements with radiochromic films and a flatbed scanner.

Authors:  O Rampado; E Garelli; R Ropolo
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

8.  Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system.

Authors:  Supawitoo Sookpeng; Chitsanupong Butdee
Journal:  Emerg Radiol       Date:  2016-12-02

9.  Setting up computed tomography automatic tube current modulation systems.

Authors:  C J Martin; S Sookpeng
Journal:  J Radiol Prot       Date:  2016-08-03       Impact factor: 1.394

Review 10.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

View more
  2 in total

1.  Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography

Authors:  Ayşegül Yurt; İsmail Özsoykal; Funda Obuz
Journal:  Mol Imaging Radionucl Ther       Date:  2019-09-06

2.  Image quality and clinical usefulness of automatic tube current modulation technology in female chest computed tomography screening.

Authors:  Cheng Li; Lin Qi; Yusheng Zhang; Feng Gao; Xiu Jin; Lukai Zhang; Huan Tang; Ming Li
Journal:  Medicine (Baltimore)       Date:  2020-08-14       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.