Computed tomography dose measurements with radiochromic films and a flatbed scanner.

O Rampado1, E Garelli, R Ropolo.   

Abstract

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6 x 170 mm2 in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 degrees-180 degrees. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 degrees) and with the axis beam perpendicular (0 degrees and 180 degrees). Integrating over a 360 degrees exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 sigma level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 sigma level of 8% were founded. The 1 sigma uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 sigma uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.

Entities:  

Mesh:

Year:  2010        PMID: 20175481     DOI: 10.1118/1.3271584

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures.

Authors:  Samuel Brady; Terry Yoshizumi; Greta Toncheva; Donald Frus
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Experimental estimates of peak skin dose and its relationship to the CT dose index using the CTDI head phantom.

Authors:  Hugo de las Heras; Ronaldo Minniti; Sean Wilson; Chad Mitchell; Marlene Skopec; Claudia C Brunner; Kish Chakrabarti
Journal:  Radiat Prot Dosimetry       Date:  2013-07-16       Impact factor: 0.972

3.  Radiation dose from X-ray examinations of impacted canines: cone beam CT vs two-dimensional imaging.

Authors:  Nils Kadesjö; Randi Lynds; Mats Nilsson; Xie-Qi Shi
Journal:  Dentomaxillofac Radiol       Date:  2018-01-16       Impact factor: 2.419

4.  Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography.

Authors:  A Al-Okshi; M Nilsson; A Petersson; M Wiese; C Lindh
Journal:  Dentomaxillofac Radiol       Date:  2013-04-22       Impact factor: 2.419

5.  Dosimetric evaluation of a 256-slice computed tomography scanner.

Authors:  Anna Radice; Claudio Ielasi; Gabriele D'Andrea; Nicoletta Paruccini; Andrea Crespi
Journal:  Radiol Med       Date:  2014-03-21       Impact factor: 3.469

6.  Dosimetric changes with computed tomography automatic tube-current modulation techniques.

Authors:  Sofia Spampinato; Anna Maria Gueli; Pietro Milone; Luigi Angelo Raffaele
Journal:  Radiol Phys Technol       Date:  2018-04-06

7.  An investigation of image guidance dose for breast radiotherapy.

Authors:  Rosemerie Alvarado; Jeremy T Booth; Regina M Bromley; Helen B Gustafsson
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

8.  Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies.

Authors:  Jarryd G Buckley; Dean Wilkinson; Alessandra Malaroda; Peter Metcalfe
Journal:  J Appl Clin Med Phys       Date:  2017-12-19       Impact factor: 2.102

9.  Gafchromic XR-QA2 film as a complementary dosimeter for hand-monitoring in CTF-guided biopsies.

Authors:  Sandra Sarmento; Joana Pereira; Maria José Sousa; Luís Cunha; Anabela G Dias; Miguel F Pereira; Augusto D Oliveira; João V Cardoso; Luis M Santos; Margarida Gouvêa; Joana Lencart; João G Alves; João A M Santos
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

10.  Radiochromic film based dosimetry of image-guidance procedures on different radiotherapy modalities.

Authors:  Ahmad Nobah; Saad Aldelaijan; Slobodan Devic; Nada Tomic; Jan Seuntjens; Mohammed Al-Shabanah; Belal Moftah
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.