Literature DB >> 18794318

Radiation dose modulation techniques in the multidetector CT era: from basics to practice.

Chang Hyun Lee1, Jin Mo Goo, Hyun Ju Ye, Sung-Joon Ye, Chang Min Park, Eun Ju Chun, Jung-Gi Im.   

Abstract

Radiation exposure to the patient has become a concern for the radiologist in the multidetector computed tomography (CT) era. With the introduction of faster multidetector CT scanners, various techniques have been developed to reduce the radiation dose to the patient; one method is automatic exposure control (AEC). AEC systems make use of different types of control, including patient-size AEC, z-axis AEC, rotational or angular AEC, or a combination of two or more of these types. AEC systems operate on the basis of several methods: standard deviation, noise index, reference milliamperage, and reference image. A clear understanding of how to use different AEC systems on different multidetector CT scanners will allow users to modulate radiation dose, reduce photon starvation artifacts, and maintain image quality throughout the body. Further development of AEC systems and their successful introduction into clinical practice will require user education and good communication between users and manufacturers. (c) RSNA, 2008.

Entities:  

Mesh:

Year:  2008        PMID: 18794318     DOI: 10.1148/rg.285075075

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  69 in total

1.  Inappropriate arm positioning during scout image acquisition resulting in increased radiation dose while performing a chest CT.

Authors:  Frank Kuo; Michael Plaza; Gaurav Saigal
Journal:  Pediatr Radiol       Date:  2012-02-10

2.  A method for calculating the dose length product from CT DICOM images.

Authors:  I A Tsalafoutas; S I Metallidis
Journal:  Br J Radiol       Date:  2010-11-16       Impact factor: 3.039

Review 3.  Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction.

Authors:  Ji Yung Choo; Jin Mo Goo; Chang Hyun Lee; Chang Min Park; Sang Joon Park; Mi-Suk Shim
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

4.  Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

Authors:  Christopher P Favazza; Lifeng Yu; Shuai Leng; James M Kofler; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2015 May-Jun       Impact factor: 1.826

Review 5.  Pediatric CT--the challenge of dose records.

Authors:  Kimberly E Applegate; Karen Thomas
Journal:  Pediatr Radiol       Date:  2011-08-17

6.  C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications.

Authors:  Hyungjin Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-04-28       Impact factor: 5.315

7.  Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2014-02-20       Impact factor: 3.469

8.  Reproducibility and variability of very low dose hepatic perfusion CT in metastatic liver disease.

Authors:  Osman Melih Topcuoğlu; Muşturay Karçaaltıncaba; Deniz Akata; Mustafa Nasuh Özmen
Journal:  Diagn Interv Radiol       Date:  2016 Nov-Dec       Impact factor: 2.630

Review 9.  Multidetector CT in children: current concepts and dose reduction strategies.

Authors:  Rutger A J Nievelstein; Ingrid M van Dam; Aart J van der Molen
Journal:  Pediatr Radiol       Date:  2010-06-10

Review 10.  State-of-the-art CT imaging techniques for congenital heart disease.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.