Literature DB >> 21961871

Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws.

Oliver P Gautschi1, Bawarjan Schatlo, Karl Schaller, Enrico Tessitore.   

Abstract

OBJECT: The technique of pedicle screw insertion is a mainstay of spinal instrumentation. Some of its potential complications are clinically relevant and may require reoperation or further postoperative care.
METHODS: A literature search was performed using MEDLINE (between 1999 and June 2011) for studies on pedicle screw placement in thoracolumbar surgery. The authors included randomized controlled trials, case-control studies, and case series (≥ 20 patients) from the English-, German-, and French-language literature. The authors assessed study type, the number of patients, the anatomical area, the number of pedicle screws, duration of follow-up, type of pedicle screw placement, incidence of complications, and type of complication. The management of specific complications is discussed.
RESULTS: Thirty-nine articles with 46 patient groups were reviewed with a total of 35,630 pedicle screws. One study was a randomized controlled trial, 8 were case-control studies, and the remaining articles were case series. Dural lesions and irritation of nerve roots were reported in a mean of 0.18% and 0.19% per pedicle screws, respectively. Thirty-two patients in 10 studies (of 5654 patients from all 39 studies) required further revision surgeries for misplaced pedicle screws causing neurological problems. None of the analyzed studies reported vascular complications, and only 2 studies reported visceral complications of clinical significance.
CONCLUSIONS: Pedicle screw placement in the thoracolumbar region is a safe procedure with an overall high accuracy and a very low rate of clinically relevant complications.

Entities:  

Mesh:

Year:  2011        PMID: 21961871     DOI: 10.3171/2011.7.FOCUS11168

Source DB:  PubMed          Journal:  Neurosurg Focus        ISSN: 1092-0684            Impact factor:   4.047


  57 in total

1.  A novel guide device improves the accuracy of pedicle screw placement.

Authors:  Lei Yang; Haijun Li; Jian Tang; Dawei Ge; Xiaojian Cao
Journal:  Int J Clin Exp Med       Date:  2015-06-15

2.  [Spinal column: implants and revisions].

Authors:  S M Krieg; H S Meyer; B Meyer
Journal:  Chirurg       Date:  2016-03       Impact factor: 0.955

3.  Tracked ultrasound snapshots in percutaneous pedicle screw placement navigation: a feasibility study.

Authors:  Tamas Ungi; Eric Moult; Joseph H Schwab; Gabor Fichtinger
Journal:  Clin Orthop Relat Res       Date:  2013-08-17       Impact factor: 4.176

4.  A comparative analysis of intensity-based 2D-3D registration for intraoperative use in pedicle screw insertion surgeries.

Authors:  Hooman Esfandiari; Carolyn Anglin; Pierre Guy; John Street; Simon Weidert; Antony J Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-10       Impact factor: 2.924

5.  Evaluation of Software-Based Metal Artifact Reduction in Intraoperative 3D Imaging of the Spine Using a Mobile Cone Beam CT.

Authors:  Maxim Privalov; Marcus Mohr; Benedict Swartman; Nils Beisemann; Holger Keil; Jochen Franke; Paul Alfred Grützner; Sven Yves Vetter
Journal:  J Digit Imaging       Date:  2020-10       Impact factor: 4.056

6.  Reliability of the Planned Pedicle Screw Trajectory versus the Actual Pedicle Screw Trajectory using Intra-operative 3D CT and Image Guidance.

Authors:  Catherine A Miller; Charles G Ledonio; Matthew A Hunt; Farhan Siddiq; David W Polly
Journal:  Int J Spine Surg       Date:  2016-10-24

7.  Feasibility of laser-guided percutaneous pedicle screw placement in the lumbar spine using a hybrid-OR.

Authors:  P H Richter; F Gebhard; M Salameh; K Schuetze; M Kraus
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-10       Impact factor: 2.924

8.  [Importance of intraoperative navigation in spinal surgery].

Authors:  P H Richter; F Gebhard; M Kraus
Journal:  Chirurg       Date:  2014-10       Impact factor: 0.955

9.  Radiological and clinical differences between robotic-assisted pedicle screw fixation with and without real-time optical tracking.

Authors:  Jinpeng Du; Lin Gao; Dageng Huang; Lequn Shan; Wentao Wang; Yong Fan; Dingjun Hao; Liang Yan
Journal:  Eur Spine J       Date:  2020-10-20       Impact factor: 3.134

Review 10.  Photoacoustic-guided surgery from head to toe [Invited].

Authors:  Alycen Wiacek; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-03-16       Impact factor: 3.732