Literature DB >> 29430474

Characterization and validation of the thorax phantom Lungman for dose assessment in chest radiography optimization studies.

Sunay Rodríguez Pérez1,2, Nicholas William Marshall3, Lara Struelens1, Hilde Bosmans3.   

Abstract

This work concerns the validation of the Kyoto-Kagaku thorax anthropomorphic phantom Lungman for use in chest radiography optimization. The equivalence in terms of polymethyl methacrylate (PMMA) was established for the lung and mediastinum regions of the phantom. Patient chest examination data acquired under automatic exposure control were collated over a 2-year period for a standard x-ray room. Parameters surveyed included exposure index, air kerma area product, and exposure time, which were compared with Lungman values. Finally, a voxel model was developed by segmenting computed tomography images of the phantom and implemented in PENELOPE/penEasy Monte Carlo code to compare phantom tissue-equivalent materials with materials from ICRP Publication 89 in terms of organ dose. PMMA equivalence varied depending on tube voltage, from 9.5 to 10.0 cm and from 13.5 to 13.7 cm, for the lungs and mediastinum regions, respectively. For the survey, close agreement was found between the phantom and the patients' median values (deviations lay between 8% and 14%). Differences in lung doses, an important organ for optimization in chest radiography, were below 13% when comparing the use of phantom tissue-equivalent materials versus ICRP materials. The study confirms the value of the Lungman for chest optimization studies.

Entities:  

Keywords:  Monte Carlo simulations; anthropomorphic phantom; chest radiography; digital radiology; optimization; organ dose; tissue equivalence

Year:  2018        PMID: 29430474      PMCID: PMC5800460          DOI: 10.1117/1.JMI.5.1.013504

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  28 in total

1.  Optimization of standard patient radiographic images for chest, skull and pelvis exams in conventional x-ray equipment.

Authors:  D R Pina; S B Duarte; T Ghilardi Netto; C S Trad; M A C Brochi; S C de Oliveira
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

2.  A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields.

Authors:  Josep Sempau; Andreu Badal; Lorenzo Brualla
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages.

Authors:  Michael Sandborg; Anders Tingberg; Gustaf Ullman; David R Dance; Gudrun Alm Carlsson
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Dose-image quality optimisation in digital chest radiography.

Authors:  P Doyle; C J Martin; D Gentle
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

5.  Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system.

Authors:  Paula Toroi; Federica Zanca; Kenneth C Young; Chantal van Ongeval; Guy Marchal; Hilde Bosmans
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 5.315

6.  A Monte Carlo-based model for simulation of digital chest tomosynthesis.

Authors:  Gustaf Ullman; David R Dance; Michael Sandborg; Gudrun Alm Carlsson; Angelica Svalkvist; Magnus Båth
Journal:  Radiat Prot Dosimetry       Date:  2010-03-04       Impact factor: 0.972

7.  Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2013-04-08       Impact factor: 3.039

8.  Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE.

Authors:  Justin Solomon; Ehsan Samei
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

9.  Evaluation of the effects of subject thickness on the exposure index in digital radiography.

Authors:  Takeshi Takaki; Kazuki Takeda; Seiichi Murakami; Haruhisa Ogawa; Masato Ogawa; Masatoshi Sakamoto
Journal:  Radiol Phys Technol       Date:  2015-11-27

10.  Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinations.

Authors:  B J Conway; P F Butler; J E Duff; T R Fewell; R E Gross; R J Jennings; G H Koustenis; J L McCrohan; F G Rueter; C K Showalter
Journal:  Med Phys       Date:  1984 Nov-Dec       Impact factor: 4.071

View more
  1 in total

1.  Translation from murine to human lung imaging using x-ray dark field radiography: A simulation study.

Authors:  Janne Vignero; Nicholas W Marshall; Greetje Vande Velde; Kristina Bliznakova; Hilde Bosmans
Journal:  PLoS One       Date:  2018-10-29       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.