Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinations.

B J Conway, P F Butler, J E Duff, T R Fewell, R E Gross, R J Jennings, G H Koustenis, J L McCrohan, F G Rueter, C K Showalter.   

Abstract

The periodic assessment of exposures in diagnostic radiology is an important part of a comprehensive quality assurance program. The most frequent radiologic examination conducted in the United States is chest radiography. Automatic exposure controlled (AEC) techniques are often used for this exam, and a standard patient-equivalent chest phantom is useful when estimating patient exposures on such systems. This is of particular importance if exposures are to be compared among AEC systems with different entrance x-ray spectra. Such a phantom has been developed to facilitate surveys of the average patient exposure from AEC posteroanterior chest radiography. The phantom is relatively lightweight and easily transportable, sturdy and made of readily available and relatively inexpensive materials (Lucite and aluminum). It accurately simulates the primary and scatter transmission through the lung-field regions of a patient-equivalent anthropomorphic phantom for x-ray spectra typically used in chest radiography. A clinical evaluation has been conducted to verify the patient equivalence of the phantom. Measurements of patient entrance skin exposure were obtained for a large number of patients on a variety of x-ray systems operated in the AEC mode using one or both lung-field detectors. Comparison of these data with exposure estimates derived from the phantom indicate that the phantom attenuates the x-ray beam in such a way that it can be employed to accurately and consistently estimate the mean exposure of the average patient under a variety of radiographic conditions. The design, development, and evaluation of the patient-equivalent attenuation phantom is described.

Entities:  

Mesh:

Year:  1984        PMID: 6513889     DOI: 10.1118/1.595611

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Mireille V Boot; Bart J A Mertens; Jacob Geleijns
Journal:  Eur Radiol       Date:  2005-08-31       Impact factor: 5.315

2.  Optimization of dose and image quality for computed radiography and digital radiography.

Authors:  Charles E Willis
Journal:  J Digit Imaging       Date:  2007-03       Impact factor: 4.056

3.  A technique for simulating the effect of dose reduction on image quality in digital chest radiography.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Jan Pieter A van Delft; Jacob Geleijns
Journal:  J Digit Imaging       Date:  2008-02-08       Impact factor: 4.056

4.  Effective DQE (eDQE) and dose to optimize radiographic technical parameters: a survey of pediatric chest X-ray examinations in Korea.

Authors:  Hye-Suk Park; Ye-Seul Kim; Ok-Seob Park; Sang-Tae Kim; Chang-Woo Jeon; Hee-Joung Kim
Journal:  Radiol Med       Date:  2013-12-12       Impact factor: 3.469

5.  Consequences of modern anthropometric dimensions for radiographic techniques and patient radiation exposures.

Authors:  Chintan Shah; A Kyle Jones; Charles E Willis
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

7.  Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors.

Authors:  Charles E Willis; Yevgeniy Y Vinogradskiy; Brad K Lofton; R Allen White
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

8.  Structural noise from automatic exposure control device and its relationship to X-ray tube voltage used for calibration of a flat-panel detector system.

Authors:  Masayoshi Mizuta; Hiroyuki Akazawa; Toshifumi Kasai; Shigeru Sanada; Shuji Abe; Shigeki Mitou
Journal:  Radiol Phys Technol       Date:  2011-08-23

9.  Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2013-04-08       Impact factor: 3.039

10.  Characterization and validation of the thorax phantom Lungman for dose assessment in chest radiography optimization studies.

Authors:  Sunay Rodríguez Pérez; Nicholas William Marshall; Lara Struelens; Hilde Bosmans
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.