Literature DB >> 23321241

Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments.

Eugenio Pedullà1, Nicola M Grande, Gianluca Plotino, Gianluca Gambarini, Ernesto Rapisarda.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the resistance to flexural fatigue of Reciproc R25 (VDW, Munich, Germany), WaveOne Primary (VDW, Munich, Germany), Mtwo (Sweden & Martina, Padova, Italy), and Twisted File (TF; SybronEndo, Orange, CA) instruments used in continuous rotation or in 2 different reciprocating motions.
METHODS: A total of 180 nickel-titanium files from 4 brands marketed, 2 for use in reciprocating motion (ie, Reciproc R25 and WaveOne Primary) and 2 for use in continuous rotation (ie, Mtwo and TF both taper .06/0.25 tip diameter), were tested. Forty-five instruments for each brand were divided into 3 groups (n = 15) on the basis of the motion tested: continuous rotation (group 1: 300 rpm) and reciprocal motion (group 2: "RECIPROC ALL" mode and group 3: "WAVEONE ALL" mode). The resistance to cyclic fatigue was determined by counting the number of cycles to failure in a 60° curve with a 5-mm radius. Data were analyzed through 2-way analyses of variance.
RESULTS: The cyclic fatigue resistance of the 2 reciprocating motion instruments (ie, "RECIPROC ALL" and "WAVEONE ALL") was significantly higher than the continuous rotation in each brand (P < .001). No significant difference was observed in cyclic fatigue between the 2 different reciprocal motions tested in each brand (P > .05). When considering the appropriate clinical motion for each brand, no significant difference in cyclic fatigue was found between TF, Mtwo, and Reciproc R25 instruments, whereas the cyclic fatigue resistance of WaveOne files was less than the other 3 brands (P < .05).
CONCLUSIONS: Reciprocal motion showed a significantly higher cyclic fatigue resistance in all brands compared with continuous rotation. No differences were found between the 2 reciprocating motions.
Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23321241     DOI: 10.1016/j.joen.2012.10.025

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  53 in total

1.  Cyclic fatigue of instruments for endodontic glide path.

Authors:  Gianluca Gambarini; Gianluca Plotino; GianPaolo Sannino; Nicola Maria Grande; Alessio Giansiracusa; Lucila Piasecki; Ulisses Xavier da Silva Neto; Dina Al-Sudani; Luca Testarelli
Journal:  Odontology       Date:  2013-11-07       Impact factor: 2.634

2.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

3.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

4.  Maintenance Evaluation of the Original Anatomy of the Root Canal Diameters Instrumented with Mtwo and BioRace Systems.

Authors:  Mimoza Canga; Vito Antonio Malagnino; Rosela Rroco; Lindita Xhemnica; Rozarka Budina; Hava Çelaj; Rezarta Kurti
Journal:  Maedica (Bucur)       Date:  2020-12

5.  Shaping ability of reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue.

Authors:  Sebastian Bürklein; Stefanie Flüch; Edgar Schäfer
Journal:  Odontology       Date:  2018-05-18       Impact factor: 2.634

6.  Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system.

Authors:  Daniely Amorin Meireles; Mariana Mena Barreto Bastos; André Augusto Franco Marques; Lucas da Fonseca Roberti Garcia; Emílio Carlos Sponchiado
Journal:  Restor Dent Endod       Date:  2013-08-23

7.  Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?

Authors:  Emmanuel João Nogueira Leal Silva; Rafael Santos Attademo; Marcia Cristina Dutra da Silva; Karem Paula Pinto; Henrique Dos Santos Antunes; Victor Talarico Leal Vieira
Journal:  Clin Oral Investig       Date:  2020-11-21       Impact factor: 3.573

8.  Mechanical resistance of carbon and stainless steel hand instruments used in a reciprocating handpiece.

Authors:  Lucila Piasecki; Dina Al-Sudani; Alessio Giansiracusa Rubini; Giampaolo Sannino; Giampaolo Sonnino; Maurizio Bossù; Luca Testarelli; Roberto Di Giorgio; Ulisses Xavier da Silva-Neto; Christian Giampietro Brandão; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

9.  Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

Authors:  Amr Elnaghy; Shaymaa Elsaka
Journal:  Clin Oral Investig       Date:  2017-10-13       Impact factor: 3.573

10.  Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study.

Authors:  Camila Galletti Espir; Camila Almeida Nascimento-Mendes; Juliane Maria Guerreiro-Tanomaru; Bruno Cavalini Cavenago; Marco Antonio Hungaro Duarte; Mário Tanomaru-Filho
Journal:  Clin Oral Investig       Date:  2018-03-10       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.