Victor de Ornelas Peraça1, Samantha Rodrigues Xavier1, Fabio de Almeida Gomes2, Luciane Geanini Pena Dos Santos1, Erick Miranda Souza3, Fernanda Geraldo Pappen1.
Abstract
OBJECTIVES: This study evaluated the effect of repeated uses and autoclaving in the instrumented area, fracture resistance, and time of instrumentation of thermally treated nickel-titanium reciprocating systems.Entities:
Keywords: Instrument fracture; Instrumentation; Reciproc Blue; Sterilization; WaveOne Gold
Year: 2021 PMID: 34123764 PMCID: PMC8170385 DOI: 10.5395/rde.2021.46.e28
Source DB: PubMed Journal: Restor Dent Endod ISSN: 2234-7658
Figure 1Example of a pre-instrumentation image achieved, and transferred to ImageJ software (version 1.43; National Institutes of Health). The image of the root canal before and after instrumentation was selected and the number of pixels per millimeter was registered through the measure tool.
Figure 2Image of the instruments achieved to illustrate fracture and locate morphological alterations before eventual fractures. (A) WaveOne Gold with no deformation or fracture; (B) Reciproc Blue after fracture.
Figure 3Graphic representation of Kaplan-Meier survival analysis. The estimated survival (number of uses to fracture) of Reciproc Blue was 8.88 uses without sterilization, and 8.36 uses when autoclaved between the uses (p = 0.085); while WaveOne Gold presented an estimated survival of 7.05 without autoclaving, and 6.88 when submitted to sterilization (p = 0.853).
Instrumented area of simulated root canals (pixels per mm2), within the different evaluated groups
| Instrument | Sterilization cycle | Instrumented area | |
|---|---|---|---|
| Reciproc Blue | No | 1,479.81 ± 1,130.91b | 0.039 |
| Yes | 791.75 ± 610.26a | ||
| WaveOne Gold | No | 1,144.38 ± 915.81ab | |
| Yes | 1,270.27 ± 770.59ab |
Values are expressed as mean ± standard deviation.
a,bDifferent superscript letters indicate statistically significant differences. *Kruskal-Wallis test.
Figure 4Graphic illustrating the reduction in the instrumented area (pixels per mm2) along the uses within the evaluated groups (WaveOne Gold and Reciproc Blue, with and without sterilization cycles).
Time to reach the working length with Reciproc Blue and WaveOne Gold, with and without sterilization cycles
| Instrument | Sterilization cycle | Preparation time (seg.) | |
|---|---|---|---|
| Reciproc Blue | No | 109.66 ± 21.17ab | 0.010 |
| Yes | 123.21 ± 23.33b | ||
| WaveOne Gold | No | 108.89 ± 21.23a | |
| Yes | 116.35 ± 15.67ab |
Values are expressed as mean ± standard deviation.
a,bDifferent superscript letters indicate statistically significant differences. *Kruskal-Wallis test.