Fast intra-fractional image-guidance with 6D positioning correction reduces delivery uncertainty for stereotactic radiosurgery and radiotherapy.

Nikolai Tarnavski1, Svend Aage Engelholm1, Per Munck Af Rosenschold1,2.   

Abstract

The purpose of this study is to analyze intra-fractional positioning uncertainty for stereotactic radiotherapy and radiosurgery of cranial tumors. Specifically, we wish to determine the use of intra-fractional image guided patient positioning verification is necessary during delivery of "frameless" stereotactic radiotherapy and radiosurgery (SRT/SRS) and non-coplanar radiation beams, and if positioning uncertainty is associated with overall treatment time. Orthogonal radiographic treatment verification data was extracted for 288 patients and 1344 fractions, and were analyzed with respect to 3D translational and angular corrections once during treatment delivery of SRT/SRS. We find that positioning corrections greater than 2 mm are required for approximately 6% of beams, and that the magnitude of the translational corrections was significantly associated with the delay time between beams (p=0.003). Further, we find that the maximum angular and translational deviations were associated (p<0.001). We conclude that a subgroup of SRT/SRS patients may have considerable positioning error unless this is monitored and corrected during treatment, and that keeping the imaging and delivery times below approximately 5 min is beneficial towards clinically relevant geographical errors. In case longer time-delays than 5 min occurs, the treatment staff should consider acquiring a new set of radiographs in order to verify the patient's position, assuming this technically feasible to be performed quickly.

Entities:  

Keywords:  IGRT; SBRT; intra-fractional positioning; patient fixation; positioning uncertainty; radiosurgery; stereotactic radiotherapy

Year:  2016        PMID: 29296422      PMCID: PMC5658830     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  11 in total

1.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

Authors:  M van Herk; P Remeijer; C Rasch; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

2.  Stereotactic body radiation therapy: the report of AAPM Task Group 101.

Authors:  Stanley H Benedict; Kamil M Yenice; David Followill; James M Galvin; William Hinson; Brian Kavanagh; Paul Keall; Michael Lovelock; Sanford Meeks; Lech Papiez; Thomas Purdie; Ramaswamy Sadagopan; Michael C Schell; Bill Salter; David J Schlesinger; Almon S Shiu; Timothy Solberg; Danny Y Song; Volker Stieber; Robert Timmerman; Wolfgang A Tomé; Dirk Verellen; Lu Wang; Fang-Fang Yin
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

Review 3.  Clinical outcomes of stereotactic radiosurgery in the treatment of patients with metastatic brain tumors.

Authors:  Ameer L Elaimy; Alexander R Mackay; Wayne T Lamoreaux; Robert K Fairbanks; John J Demakas; Barton S Cooke; Christopher M Lee
Journal:  World Neurosurg       Date:  2011 May-Jun       Impact factor: 2.104

4.  Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging.

Authors:  Guang Li; Ase Ballangrud; Li Cheng Kuo; Hyejoo Kang; Assen Kirov; Michael Lovelock; Yoshiya Yamada; James Mechalakos; Howard Amols
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

6.  Setup accuracy of the Novalis ExacTrac 6DOF system for frameless radiosurgery.

Authors:  Thierry Gevaert; Dirk Verellen; Koen Tournel; Nadine Linthout; Samuel Bral; Benedikt Engels; Christine Collen; Tom Depuydt; Michael Duchateau; Truus Reynders; Guy Storme; Mark De Ridder
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-04-07       Impact factor: 7.038

7.  Real-time dynamic MLC tracking for inversely optimized arc radiotherapy.

Authors:  Marianne Falk; Per Munck af Rosenschöld; Paul Keall; Herbert Cattell; Byung Chul Cho; Per Poulsen; Sergey Povzner; Amit Sawant; Jens Zimmerman; Stine Korreman
Journal:  Radiother Oncol       Date:  2010-01-19       Impact factor: 6.280

Review 8.  Frameless stereotactic radiosurgery with mobile CT, mask immobilization and micro-multileaf collimators.

Authors:  H Takeuchi; M Yoshida; T Kubota; H Ishii; K Sato; Y Handa; H Itoh
Journal:  Minim Invasive Neurosurg       Date:  2003-04

Review 9.  Stereotactic radiosurgery for the treatment of brain metastases.

Authors:  Falk Müller-Riemenschneider; Angelina Bockelbrink; Iris Ernst; Christoph Schwarzbach; Christoph Vauth; J-Matthias Graf von der Schulenburg; Stefan N Willich
Journal:  Radiother Oncol       Date:  2009-01-08       Impact factor: 6.280

10.  Intra-fraction setup variability: IR optical localization vs. X-ray imaging in a hypofractionated patient population.

Authors:  Maria Francesca Spadea; Barbara Tagaste; Marco Riboldi; Eleonora Preve; Daniela Alterio; Gaia Piperno; Cristina Garibaldi; Roberto Orecchia; Antonio Pedotti; Guido Baroni
Journal:  Radiat Oncol       Date:  2011-04-15       Impact factor: 3.481

View more
  8 in total

1.  Operation and calibration of the novel PTW 1600SRS detector for the verification of single isocenter stereotactic radiosurgery treatments of multiple small brain metastases.

Authors:  Esther Decabooter; Ans Cc Swinnen; Michel C Öllers; Fabian Göpfert; Frank Verhaegen
Journal:  Br J Radiol       Date:  2021-06-11       Impact factor: 3.629

2.  Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques.

Authors:  Georgia Prentou; Eleftherios P Pappas; Andreas Logothetis; Efi Koutsouveli; Evaggelos Pantelis; Panagiotis Papagiannis; Pantelis Karaiskos
Journal:  J Appl Clin Med Phys       Date:  2020-02-05       Impact factor: 2.102

3.  Combined effect of dose gradient and rotational error on prescribed dose coverage for single isocenter multiple brain metastases in frameless stereotactic radiotherapy.

Authors:  Jai-Woong Yoon; Soah Park; Kwang-Ho Cheong; Sei-Kwon Kang; Tae Jin Han
Journal:  Radiat Oncol       Date:  2021-08-31       Impact factor: 3.481

4.  Plan Quality Assessment of Fractionated Stereotactic Radiotherapy Treatment Plans in Patients With Brain Metastases.

Authors:  Mihály Simon; Judit Papp; Emese Csiki; Árpád Kovács
Journal:  Front Oncol       Date:  2022-03-08       Impact factor: 6.244

5.  CBCT Verification of SRT for Patients With Brain Metastases.

Authors:  Judit Papp; Mihály Simon; Emese Csiki; Árpád Kovács
Journal:  Front Oncol       Date:  2022-01-19       Impact factor: 6.244

6.  The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases.

Authors:  Ans C C Swinnen; Michel C Öllers; Chin Loon Ong; Frank Verhaegen
Journal:  J Appl Clin Med Phys       Date:  2020-04-01       Impact factor: 2.102

Review 7.  Recent advanced in Surface Guided Radiation Therapy.

Authors:  P Freislederer; M Kügele; M Öllers; A Swinnen; T-O Sauer; C Bert; D Giantsoudi; S Corradini; V Batista
Journal:  Radiat Oncol       Date:  2020-07-31       Impact factor: 3.481

8.  A retrospective analysis of setup and intrafraction positional variation in stereotactic radiotherapy treatments.

Authors:  Micah Barnes; Adam Yeo; Kenton Thompson; Claire Phillips; Tomas Kron; Nicholas Hardcastle
Journal:  J Appl Clin Med Phys       Date:  2020-11-03       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.