Literature DB >> 12761677

Frameless stereotactic radiosurgery with mobile CT, mask immobilization and micro-multileaf collimators.

H Takeuchi1, M Yoshida, T Kubota, H Ishii, K Sato, Y Handa, H Itoh.   

Abstract

We present frameless stereotactic radiosurgery using mobile CT, thermal plastic mask fixation, a vacuum-form body immobilizer and micro-multileaf collimators. A linear accelerator and a self-moving helical CT scanner gantry were installed in the same room. The isocenter of irradiation can be also aligned with the center of the CT gantry by rotating the couch. A thermal plastic mask and vacuum-form body immobilizer was used for registration and immobilization. The advantages of this system are as follows: 1) Accurate and painless frameless fractionated irradiation can be performed smoothly, as the patient's head is fixed without exchanging the couch from CT scanning to irradiation system. 2) This mask system can be applied to children, infants or adults with a previous craniotomy bone flap that must have a fixation pin placed into it. This system can be also used for fractionated radiotherapy without painful skull pin-fixed frame. 3) 1 mm micro-multileaf collimators enable irregular contour irradiation. 4) Image fusion (among CT, MRI, angiography, and PET) and 3D images can be used for irradiation planning. 5) This system can be used on any part of the body. 6) This system can be installed in any irradiation room without any extension or new construction.

Entities:  

Mesh:

Year:  2003        PMID: 12761677     DOI: 10.1055/s-2003-39342

Source DB:  PubMed          Journal:  Minim Invasive Neurosurg        ISSN: 0946-7211


  4 in total

1.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

2.  Fast intra-fractional image-guidance with 6D positioning correction reduces delivery uncertainty for stereotactic radiosurgery and radiotherapy.

Authors:  Nikolai Tarnavski; Svend Aage Engelholm; Per Munck Af Rosenschold
Journal:  J Radiosurg SBRT       Date:  2016

3.  Study on the clinical application of pulsed DC magnetic technology for tracking of intraoperative head motion during frameless stereotaxy.

Authors:  Olaf Suess; Silke Suess; Sven Mularski; Björn Kühn; Thomas Picht; Stefanie Hammersen; Rüdiger Stendel; Mario Brock; Theodoros Kombos
Journal:  Head Face Med       Date:  2006-04-26       Impact factor: 2.151

4.  Six degrees of freedom CBCT-based positioning for intracranial targets treated with frameless stereotactic radiosurgery.

Authors:  Anees Dhabaan; Eduard Schreibmann; Arsalan Siddiqi; Eric Elder; Tim Fox; Tomi Ogunleye; Natia Esiashvili; Walter Curran; Ian Crocker; Hui-Kuo Shu
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.