Literature DB >> 29266624

Applications of corneal topography and tomography: a review.

Rachel Fan1, Tommy Cy Chan2, Gaurav Prakash3, Vishal Jhanji2,4,5.   

Abstract

Corneal imaging is essential for diagnosing and management of a wide variety of ocular diseases. Corneal topography is used to characterize the shape of the cornea, specifically, the anterior surface of the cornea. Most corneal topographical systems are based on Placido disc that analyse rings that are reflected off the corneal surface. The posterior corneal surface cannot be characterized using Placido disc technology. Imaging of the posterior corneal surface is useful for diagnosis of corneal ectasia. Unlike corneal topographers, tomographers generate a three-dimensional recreation of the anterior segment and provide information about the corneal thickness. Scheimpflug imaging is one of the most commonly used techniques for corneal tomography. The cross-sectional images generated by a rotating Scheimpflug camera are used to locate the anterior and posterior corneal surfaces. The clinical uses of corneal topography include, diagnosis of corneal ectasia, assessment of corneal astigmatism, and refractive surgery planning. This review will discuss the applications of corneal topography and tomography in clinical practice.
© 2017 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  agreement; cornea; repeatability; tomography; topography

Mesh:

Year:  2018        PMID: 29266624     DOI: 10.1111/ceo.13136

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  16 in total

1.  Comparison of the effects of femtosecond laser energy on corneal endothelium at two different dissection levels in femtosecond laser-assisted deep anterior lamellar keratoplasty for keratoconus.

Authors:  Mustafa Saber Hafez; Ismail Hamza; Walid Mohamed El-Zawahry; Ashraf Hassan Soliman
Journal:  Int Ophthalmol       Date:  2021-01-05       Impact factor: 2.031

2.  Performances of Corneal Topography and Tomography in the Diagnosis of Subclinical and Clinical Keratoconus.

Authors:  Cristina Ariadna Nicula; Adriana Elena Bulboacă; Dorin Nicula; Ariadna Patricia Nicula; Karin Ursula Horvath; Sorana D Bolboacă
Journal:  Front Med (Lausanne)       Date:  2022-05-26

3.  Comments on: Repeatability of Orbscan III for anterior segment parameters in normal eyes.

Authors:  Bharat Gurnani; Kirandeep Kaur
Journal:  Indian J Ophthalmol       Date:  2021-05       Impact factor: 1.848

4.  Phakic intraocular lens: Getting the right size.

Authors:  Kalyaani Deshpande; Rushad Shroff; Partha Biswas; Kamal Kapur; Naren Shetty; Ann Sarah Koshy; Pooja Khamar
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

5.  Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes.

Authors:  Yong Li; Zhiqiang Xu; Qiaoli Liu; Yuzhou Wang; Kan Lin; Jiahui Xia; Shihao Chen; Liang Hu
Journal:  Eye Vis (Lond)       Date:  2021-01-08

6.  Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer.

Authors:  Tommy C Y Chan; Marco C Y Yu; Vivian Chiu; Gilda Lai; Christopher K S Leung; Poemen P M Chan
Journal:  Sci Rep       Date:  2021-07-21       Impact factor: 4.379

7.  Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters.

Authors:  Mustafa Doğan; Mehmet Cem Sabaner; Mehmet Akif Erol
Journal:  J Ophthalmol       Date:  2018-09-05       Impact factor: 1.909

8.  Studying the factors related to refractive error regression after PRK surgery.

Authors:  Mehdi Naderi; Siamak Sabour; Soheila Khodakarim; Farid Daneshgar
Journal:  BMC Ophthalmol       Date:  2018-08-14       Impact factor: 2.209

Review 9.  Biometric Measurement of Anterior Segment: A Review.

Authors:  Bin Liu; Chengwei Kang; Fengzhou Fang
Journal:  Sensors (Basel)       Date:  2020-07-31       Impact factor: 3.576

10.  Differences between Scheimpflug and optical coherence tomography in determining safety distances in eyes with an iris-fixating phakic intraocular lens.

Authors:  Zoraida S Gaurisankar; Gwyneth A van Rijn; Gregorius P M Luyten; Jan-Willem M Beenakker
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-08-06       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.