| Literature DB >> 30107828 |
Mehdi Naderi1, Siamak Sabour2, Soheila Khodakarim1, Farid Daneshgar3.
Abstract
BACKGTOUND: Photorefractive keratectomy (PRK) is used for a wide range of refractive errors such as low to moderate myopia, hyperopia and astigmatism. While many improvements have been made in laser application and accuracy as well as the modes of corneal flap removal, and although the results are somewhat predictable, regression of refractive errors is still a common complaint among the patients undergoing refractive surgery with Excimer Laser. We aimed to determine related factors of regression following photorefractive keratectomy (PRK) in different types of refractive errors.Entities:
Keywords: PRK surgery; Refractive error regression; Related factors
Mesh:
Year: 2018 PMID: 30107828 PMCID: PMC6092795 DOI: 10.1186/s12886-018-0879-y
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Flow chart of the study population
Preoperative characteristics in 293 eyes that undergo PRK Surgery
| Factor | Frequency | Percent |
|---|---|---|
| Female | 180 | 61.4 |
| Men | 113 | 38.6 |
| Education degree | ||
| Under diploma | 47 | 16 |
| Diploma | 91 | 31.1 |
| Bachelor | 115 | 39.2 |
| Post graduate | 40 | 13.7 |
| Optical zone | ||
| 5.5 (mm) | 7 | 2.1 |
| 6.00 (mm) | 20 | 6.8 |
| 6.50 (mm) | 267 | 91.1 |
| Refraction type | ||
| Myopia (D) | 16 | 5.5 |
| Hyperopia (D) | 3 | 1 |
| Astigmatism (D) | 14 | 4.8 |
| Myopic astigmatism (D) | 223 | 76.1 |
| Hyperopic astigmatism (D) | 37 | 12.6 |
| Surgeon specialty | ||
| Ophthalmologist | 135 | 46.1 |
| Deviation specialty | 51 | 17.4 |
| Retina specialty | 34 | 11.6 |
| Cornea specialty | 73 | 24.9 |
| Astigmatism category (D) | ||
| Astigmatism category (0–2) D | 243 | 82.9 |
| Astigmatism category (2–4) D | 47 | 16 |
| Astigmatism category (4–6) D | 3 | 1 |
| Sphere category (D) | ||
| Sphere category (0–2) D | 93 | 31.7 |
| Sphere category (2–4) D | 110 | 37.5 |
| Sphere category (4–6) D | 50 | 17.1 |
| Sphere category (6–8) D | 22 | 7.5 |
| Sphere category (8<) D | 18 | 6.1 |
| Total | 293 | 100 |
PRK photorefractive keratectomy, D Diopter
Preoperative characteristics in 293 eye that undergo PRK surgery
| Factor | Minimum | Maximum | Mean | Std. deviation |
|---|---|---|---|---|
| Age (y) | 20 | 60 | 31.4 | 7.7 |
| Irregularity 3 (mm) | 0.4 | 2.4 | 1.02 | 0.33 |
| Irregularity 5 (mm) | 0.80 | 4.90 | 1.41 | 0.44 |
| Diff posterior (mm) | 0.01 | 0.04 | 0.02 | 0.01 |
| SimK (D) | 0.1 | 3.8 | 1.2 | 0.7 |
| Thickness (μm) | 453 | 610 | 543.6 | 32.8 |
| Eye movement (mm) | 0 | 24 | 3.9 | 2.9 |
| Sphere value (D) | 0 | 12 | 3.4 | 2.3 |
| Astigmatism value (D) | 0 | 4.75 | 1.3 | 0.94 |
PRK Photorefractive keratectomy, Diff posterior: steepest posterior point difference from Best fit sphere, simulated k astigmatism: keratometry astigmatism, D Diopter, y year
Comparison of preoperative characteristics of the eyes with and without regression
| Characteristics | Mean | ||
|---|---|---|---|
| No regression | Regression | ||
| Age (y) | 31.4 | 31.8 | 0.72 |
| Thickness(μm) | 535.7 | 529.7 | 0.21 |
| Irregularity 3 (mm) | 0.99 | 1.16 | 0.001 |
| Irregularity 5 (mm) | 1.36 | 1.61 | 0.001 |
| Diff posterior (mm) | 0.02 | 0.02 | 0.34 |
| SimK (D) | 1.06 | 1.69 | 0.001 |
| Eye movement (mm) | 3.80 | 4.56 | 0.07 |
| Sphere value (D) | 3.07 | 5.17 | 0.001 |
| Astigmatism value (D) | 1.09 | 2.05 | 0.001 |
PRK Photorefractive keratectomy, Diff posterior: steepest posterior point difference from Best fit sphere, Sim k astigmatism: simulated keratometry astigmatism, P value: Independent T test
Relationship between Refractive error regression after PRK Surgery and preoperative variables in people with both eyes regressed and both eyes non-regressed
| Variables | People whose both eyes were non regressed after surgery | People whose both eyes were regressed after surgery | ||||
|---|---|---|---|---|---|---|
| Right eye | Left eye | Test | Right eye | Left eye | Test | |
| Mean ± SD | Mean ± SD | Mead(min-max) | Mead(min-max) | |||
| Thickness (μm) | 536.7 ± 32.6 | 537.6 ± 34.7 | 0.84 | 537.5 (499–572) | 531 (501–575) | 0.49 |
| Irregularity5(mm) | 1.33 ± 0.31 | 1.36 ± 0.38 | 0.55 | 1.35 (1.00–2.70) | 1.25 (0.9–2.6) | 0.45 |
| Astigmatism(D) | 0.99 ± 0.70 | 1.07 ± 0.73 | 0.43 | 1.62 (0–3.75) | 1.87 (0–4.25) | 0.43 |
| Sphere (D) | 3.17 ± 1.69 | 3.12 ± 1.70 | 0.84 | 6.25 (0.25–12) | 7.87 (0–11.50) | 0.41 |
| SimK (D) | 0.97 ± 0.49 | 1.04 ± 0.51 | 0.30 | 1.25 (0.25–2.90) | 1.50 (0.50–2.90) | 0.92 |
PRK Photorefractive keratectomy, Sim k astigmatism: simulated keratometry astigmatism, P value: §: Independent sample t. test ®; Mann –Whitney U independent sample test
Relationship between refractive error regression after PRK surgery and preoperative variables in 16 patients who had one regressed and one non-regressed eyes
| Variables | People whose right eyes were regressed after surgery but their left eyes were not surgery | People Whose left eyes were regressed after surgery but their right eyes were not | ||||
|---|---|---|---|---|---|---|
| Right eye | Left eye | Test | Right eye | Left eye | Test | |
| Mead(minmax) | Mead(minmax) | Mead(min-max) | Mead(min-max) | |||
| Thickness (μm) | 526 (466–573) | 520 (474–588) | 0.94 | 505 (470–558) | 514 (461–562) | 0.72 |
| Irregularity 5 (mm) | 2.20 (1.70–4.90) | 1.80 (1.20–2.10) | 0.03 | 1.20 (1.00–2.30) | 1.60 (1.10–2.40) | 0.08 |
| Astigmatism (D) | 3.00 (1.50–4.75) | 2.25 (1.00–3.75) | 0.36 | 1.5 (1.25–2.75) | 2.25 (0.50–4.25) | 0.14 |
| Sphere (D) | 0.50 (0–5.00) | 0.50 (0–4.25) | 0.79 | 2.25 (0.25–7.00) | 2.00 (0.50–8.25) | 0.82 |
| SimK (D) | 2.50 (0.6–3.80) | 2.7 (0.9–3.00) | 0.94 | 1.30 (0.80–2.10) | 1.75 (0.70–2.90) | 0.21 |
PRK Photorefractive keratectomy, Sim k astigmatism simulated keratometry Astigmatism, D Diopter, P value: §: Mann –Whitney Uindependent sample test
Generalized Estimating Equations of independent variable of regression after PRK
| Factor | OR (%95 C. I) | |
|---|---|---|
| Age (years) | 1.01 (0.95 to 1.06) | 0.69 |
| Sex (male vs. female) | 1.28 (0.29 to 1.91) | 0.79 |
| Thickness (μm) | 0.99 (0.98 to 1.03) | 0.12 |
| Irregularity 5 (mm) | 3.56 (1.32 to 9.22) | 0.01 |
| SimK (D) | 2.80 (1.01 to 8.20) | 0.04 |
| Astigmatism value (D) | 2.01 (0.98 to 4.92) | 0.06 |
| Sphere value (D) | 1.98 (1.59 to 2.54) | 0.01 |
| Right or Left | 1.07 (0.69 to 1.87) | 0.80 |
Adjusted odds ratio: age, sex, thickness, irregularity 5 mm, simulated keratometry astigmatism, Astigmatism value, Sphere value
Comparing the results of GEE analysis in women and men to examine the role of gender moderating
| Factor | Male ( | Female ( | ||
|---|---|---|---|---|
| OR (%95 C. I) | OR (%95 C. I) | |||
| Age (years) | 0.25 | 1.04 (0.81 to 4.05) | 0.71 | 0.98 (0.90 to 1.06) |
| Left or right eye | 0.75 | 0.88 (0.30 to 2.35) | 0.67 | 1.18 (0.53 to 2.64) |
| Thickness (μm) | 0.02 | 0.97 (0.94 to 0.99) | 0.66 | 0.99 (0.98 to 1.03) |
| Irregularity 5 (mm) | 0.09 | 4.00 (0.85 to 19.48) | 0.02 | 4.14 (1.17 to 14.58) |
| SimK (D) | 0.54 | 1.71 (0.39 to 10.8) | 0.04 | 3.61 (1.05 to 12.43) |
| Astigmatism value (D) | 0.10 | 4.78 (0.72 to 33.01) | 0.23 | 1.81 (0.86 to 4.84) |
| Sphere value (D) | 0.01 | 1.90 (1.39 to 2.60) | 0.01 | 2.30 (1.66 to 3.18) |
Odds ratio: age, thickness, irregularity 5 mm, simulated keratometry astigmatism, astigmatism value, sphere value, D Diopter
Comparing the results of GEE analysis in eyes hyperopic astigmatism and myopic astigmatism
| Factor | Myopic astigmatism | Hyperopic astigmatism | ||
|---|---|---|---|---|
| OR (%95 C. I) | OR (%95 C. I) | |||
| Sex (male vs. female) | 0.80 | 1.18 (0.31 to 4.39) | 0.65 | 1.61 (0.19 to 13.41) |
| Age (years) | 0.80 | 0.98 (0.89 to 1.09) | 0.75 | 0.98 (0.89 to 1.08) |
| Left or right eye | 0.50 | 0.79 (0.40 to 1.56) | 0.96 | 0.95 (0.15 to 6.09) |
| Thickness (μm) | 0.13 | 0.98 (0.97 to 1.03) | 0.51 | 0.98 (0.93 to 1.03) |
| Irregularity 5 (mm) | 0.02 | 4.04 (1.24 to 13.13) | 0.74 | 1.43 (0.16 to 12.98) |
| SimK (D) | 0.02 | 5.11 (1.26 to 20.58) | 0.66 | 0.69 (0.13 to 3.60) |
| Astigmatism value (D) | 0.58 | 1.33 (0.48 to 3.59) | 0.17 | 4.37 (0.51 to 37.44) |
| Sphere value (D) | 0.01 | 2.41 (1.72 to 3.36) | 0.01 | 2.16 (1.51 to 3.11) |
Odds ratio: age, thickness, irregularity 5 mm, simulated keratometry astigmatism, astigmatism value, sphere value, D Diopter