Literature DB >> 19258608

Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck.

E Sariali1, A Mouttet, G Pasquier, E Durante, Y Catone.   

Abstract

Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan. The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm (SD 3.5) craniocaudally and 1.2 mm (SD 2) laterally. Limb length was restored with a mean accuracy of 0.3 mm (SD 3.3) and femoral offset with a mean accuracy of 0.8 mm (SD 3.1). This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length.

Entities:  

Mesh:

Year:  2009        PMID: 19258608     DOI: 10.1302/0301-620X.91B3.21390

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  26 in total

1.  Re: Increased anteversion of press-fit femoral stems compared with anatomic femur.

Authors:  Michael Wettstein; Elyazid Mouhsine
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Kenji Fujita; Kazuhiro Hasegawa; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-05

3.  CORR Insights®: Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2017-02-24       Impact factor: 4.176

4.  Evaluation of the accuracy of femoral component orientation by the CT-based fluoro-matched navigation system.

Authors:  Shinya Hayashi; Takayuki Nishiyama; Takaaki Fujishiro; Shingo Hashimoto; Noriyuki Kanzaki; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2013-03-20       Impact factor: 3.075

5.  The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-06-22

6.  How to best measure femoral length and lateralisation after total hip arthroplasty on antero-posterior pelvic radiographs.

Authors:  Nicolas Bonin; Laurent Jacquot; Laurent Boulard; Patrick Reynaud; Mo Saffarini; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-03-01       Impact factor: 3.075

7.  Reliability and accuracy of digital templating for the humeral component of total shoulder arthroplasty.

Authors:  Christopher S Lee; Shane M Davis; Christianne J Lane; Ryan C Koonce; Andrew P Hartman; Kenneth Ball; James C Esch
Journal:  Shoulder Elbow       Date:  2014-09-07

8.  Clinical outcomes following arthroscopic treatment of femoro-acetabular impingement using a minimal traction approach and an initial capsulotomy. Minimum two year follow-up.

Authors:  Elhadi Sariali; Filippo Vandenbulcke
Journal:  Int Orthop       Date:  2018-03-23       Impact factor: 3.075

9.  Two-incisions direct anterior approach for THR: Surgical technique and early outcome.

Authors:  Ritesh Rathi; Idriss Tourabaly; Alexis Nogier
Journal:  J Orthop       Date:  2017-06-28

10.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

View more