Literature DB >> 17463111

Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation.

N Sugano1, T Nishii, H Miki, H Yoshikawa, Y Sato, S Tamura.   

Abstract

We have developed a CT-based navigation system using infrared light-emitting diode markers and an optical camera. We used this system to perform cementless total hip replacement using a ceramic-on-ceramic bearing couple in 53 patients (60 hips) between 1998 and 2001. We reviewed 52 patients (59 hips) at a mean of six years (5 to 8) postoperatively. The mid-term results of total hip replacement using navigation were compared with those of 91 patients (111 hips) who underwent this procedure using the same implants, during the same period, without navigation. There were no significant differences in age, gender, diagnosis, height, weight, body mass index, or pre-operative clinical score between the two groups. The operation time was significantly longer where navigation was used, but there was no significant difference in blood loss or navigation-related complications. With navigation, the acetabular components were placed within the safe zone defined by Lewinnek, while without, 31 of the 111 components were placed outside this zone. There was no significant difference in the Merle d'Aubigne and Postel hip score at the final follow-up. However, hips treated without navigation had a higher rate of dislocation. Revision was performed in two cases undertaken without navigation, one for aseptic acetabular loosening and one for fracture of a ceramic liner, both of which showed evidence of neck impingement on the liner. A further five cases undertaken without navigation showed erosion of the posterior aspect of the neck of the femoral component on the lateral radiographs. These seven impingement-related mechanical problems correlated with malorientation of the acetabular component. There were no such mechanical problems in the navigated group. We conclude that CT-based navigation increased the precision of orientation of the acetabular component and control of limb length in total hip replacement, without navigation-related complications. It also reduced the rate of dislocation and mechanical problems related to impingement.

Entities:  

Mesh:

Year:  2007        PMID: 17463111     DOI: 10.1302/0301-620X.89B4.18458

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  37 in total

Review 1.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Navigated non-image-based positioning of the acetabulum during total hip replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri; Jean-Claude Dosch; Marius Uscatu; Eugen Ciobanu
Journal:  Int Orthop       Date:  2007-11-13       Impact factor: 3.075

3.  Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?

Authors:  Nobuhiko Sugano; Masaki Takao; Takashi Sakai; Takashi Nishii; Hidenobu Miki
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  The value of computed tomography based navigation in revision total hip arthroplasty.

Authors:  Kazunari Kuroda; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Shin Watanabe; Shintaro Iwai; Fujita Kenji; Kazuhiro Hasegawa; Daisuke Inoue; Hiroyuki Tsuchiya
Journal:  Int Orthop       Date:  2013-11-19       Impact factor: 3.075

5.  Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

Authors:  Takehito Hananouchi; Masanobu Saito; Tsuyoshi Koyama; Nobuhiko Sugano; Hideki Yoshikawa
Journal:  Clin Orthop Relat Res       Date:  2009-07-24       Impact factor: 4.176

6.  Computer navigation in total hip replacement: a meta-analysis.

Authors:  Rajiv Gandhi; Anthony Marchie; Forough Farrokhyar; Nizar Mahomed
Journal:  Int Orthop       Date:  2008-04-03       Impact factor: 3.075

7.  Improvement of activities of daily living after total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Yuki Maeda; Nobuo Nakamura; Nobuhiko Sugano
Journal:  J Artif Organs       Date:  2017-02-27       Impact factor: 1.731

Review 8.  Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature.

Authors:  Inge H F Reininga; Wiebren Zijlstra; Robert Wagenmakers; Alexander L Boerboom; Bregtje P Huijbers; Johan W Groothoff; Sjoerd K Bulstra; Martin Stevens
Journal:  BMC Musculoskelet Disord       Date:  2010-05-17       Impact factor: 2.362

9.  THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.

Authors:  William G Hamilton; James P McAuley; Douglas A Dennis; Jeffrey A Murphy; Thomas J Blumenfeld; Joel Politi
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

Review 10.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.