Literature DB >> 29224061

Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments.

Murilo Priori Alcalde1, Marco Antonio Hungaro Duarte1, Clovis Monteiro Bramante1, Bruno Carvalho de Vasconselos2, Mario Tanomaru-Filho3, Juliane Maria Guerreiro-Tanomaru3, Jader Camilo Pinto3, Marcus Vinicius Reis Só4, Rodrigo Ricci Vivan5.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the cyclic and torsional fatigue resistance of the reciprocating single-file systems Reciproc Blue 25.08 (VDW GmbH, Munich, Germany), Prodesign R 25.06 (Easy Dental Equipment, Belo Horizonte, Brazil), and WaveOne Gold 25.07 (Dentsply/Tulsa Dental Specialties, Tulsa, OK, USA).
MATERIALS AND METHODS: Sixty reciprocating instruments of the systems Reciproc Blue R25 (RB #25 .08 taper), Prodesign R (PDR #25 .06 taper), and WaveOne Gold (WOG #25 .07 taper) (n = 20) were used. Cyclic fatigue resistance testing was performed by measuring the time to failure in an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius located 5 mm from the tip (n = 10). The torsional test (ISO 3630-1) evaluated the torque and angle of rotation at failure of new instruments (n = 10) in the portion 3 mm from the tip. The fractured surface of each fragment was also observed using scanning electron microscopy (SEM). In addition, a supplementary examination was performed to measure the cross-sectional area of each instrument 3 and 5 mm from the tip. The data were analyzed using one-way ANOVA and Tukey's test, and the level of significance was set at 5%.
RESULTS: The cyclic fatigue resistance values of PDR 25.06 were significantly higher (P < 0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P < 0.05). The torsional test showed that PDR 25.06 had lower torsional strength (P < 0.05). No differences were observed between RB 25.08 and WOG 25.07 (P > 0.05). PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P < 0.05). RB 25.08 presented higher angular rotation than WOG 25.07 (P < 0.05). The cross-sectional area analysis showed that PDR 25.06 presented the smallest cross-sectional areas at 3 and 5 mm from the tip (P < 0.05).
CONCLUSION: PDR 25.06 presented the highest cyclic fatigue resistance and angular rotation until fracture compared to RB 25.08 and WOG 25.07. In addition, RB 25.08 and WOG 25.07 had higher torsional strength than PDR 25.06. CLINICAL RELEVANCE: In endodontic practice, thermally treated reciprocating instruments have been used for the root canal preparation of curved and constricted canals; therefore, these instruments should present high flexibility and suitable torsional strength to minimize the risk of instrument fracture.

Entities:  

Keywords:  Cyclic fatigue; NiTi alloy; Reciprocating motion; Thermal treatment

Mesh:

Substances:

Year:  2017        PMID: 29224061     DOI: 10.1007/s00784-017-2295-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  34 in total

1.  A mathematical model for describing the mechanical behaviour of root canal instruments.

Authors:  E W Zhang; G S P Cheung; Y F Zheng
Journal:  Int Endod J       Date:  2010-10-11       Impact factor: 5.264

2.  Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments.

Authors:  Maria Guiomar Azevedo Bahia; Marta C C Melo; Vicente Tadeu Lopes Buono
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-09-30

3.  Effect of movement kinematics on the cyclic fatigue resistance of nickel-titanium instruments.

Authors:  E Karataş; H Arslan; M Büker; F Seçkin; I D Çapar
Journal:  Int Endod J       Date:  2015-04-16       Impact factor: 5.264

4.  Influence of clinical use on physical-structural surface properties and electrochemical potential of NiTi endodontic instruments.

Authors:  E S J Pereira; C C F Amaral; J A C P Gomes; O A Peters; V T L Buono; M G A Bahia
Journal:  Int Endod J       Date:  2017-04-29       Impact factor: 5.264

5.  Evaluation of the Cyclic Fatigue and Torsional Resistance of Novel Nickel-Titanium Rotary Files with Various Alloy Properties.

Authors:  Mehmet Emin Kaval; Ismail Davut Capar; Hüseyin Ertas
Journal:  J Endod       Date:  2016-10-21       Impact factor: 4.171

6.  Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments.

Authors:  Mustafa Gündoğar; Taha Özyürek
Journal:  J Endod       Date:  2017-05-17       Impact factor: 4.171

7.  Mechanical properties of controlled memory and superelastic nickel-titanium wires used in the manufacture of rotary endodontic instruments.

Authors:  Hui-Min Zhou; Ya Shen; Wei Zheng; Li Li; Yu-feng Zheng; Markus Haapasalo
Journal:  J Endod       Date:  2012-09-10       Impact factor: 4.171

8.  Evidence for Reduced Fatigue Resistance of Contemporary Rotary Instruments Exposed to Body Temperature.

Authors:  Rafaela Andrade de Vasconcelos; Sarah Murphy; Claudio Antonio Talge Carvalho; Rajiv G Govindjee; Sanjay Govindjee; Ove A Peters
Journal:  J Endod       Date:  2016-03-15       Impact factor: 4.171

9.  Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature.

Authors:  H S Topçuoğlu; S Düzgün; A Aktı; G Topçuoğlu
Journal:  Int Endod J       Date:  2016-07-26       Impact factor: 5.264

10.  Bending resistance and cyclic fatigue of a new heat-treated reciprocating instrument.

Authors:  Emmanuel João Nogueira Leal Silva; Cristiane Rodrigues; Victor Talarico Leal Vieira; Felipe Gonçalves Belladonna; Gustavo De-Deus; Hélio Pereira Lopes
Journal:  Scanning       Date:  2016-06-11       Impact factor: 1.932

View more
  10 in total

1.  Influence of different motions on the cyclic fatigue resistance of Reciproc and Reciproc Blue endodontic instruments.

Authors:  Marco Serafin; Matteo De Biasi; Vittorio Franco; Luigi Generali; Daniele Angerame
Journal:  J Conserv Dent       Date:  2020-08-04

2.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

3.  Comparison of Shaping Ability of Different Single-File Systems Using Microcomputed Tomography.

Authors:  Mohamed Mohamed Elashiry; Shehab Eldin Saber; Salma Hasan Elashry
Journal:  Eur J Dent       Date:  2020-01-31

4.  Mechanical Properties of ProTaper Gold, EdgeTaper Platinum, Flex Gold and Pro-T Rotary Systems.

Authors:  Murilo Alcalde; Marco Antonio Hungaro Duarte; Pablo Andrés Amoroso Silva; Pedro Henrique Souza Calefi; Emmanuel Silva; Jussaro Duque; Rodrigo Vivan
Journal:  Eur Endod J       Date:  2020-12

5.  Bending resistance and cyclic fatigue resistance of WaveOne Gold, Reciproc Blue, and HyFlex EDM instruments.

Authors:  Soram Oh; Kee-Yeon Kum; Hyun-Jung Kim; Su-Young Moon; Hyeon-Cheol Kim; Antonis Chaniotis; Hiran Perinpanayagam; Eugenio Pedullá; Seok Woo Chang
Journal:  J Dent Sci       Date:  2019-12-30       Impact factor: 2.080

6.  Cyclic Fatigue and Torsional Resistance of Four Martensite-Based Nickel Titanium Reciprocating Instruments.

Authors:  Emmanuel Silva; Carolina Oliveira de Lima; Victor Vieira; Henrique Antunes; Edson Jorge Lima Moreira; Marco Versiani
Journal:  Eur Endod J       Date:  2020-12

7.  Assessment of postoperative pain after single-visit root canal treatment using rotary and reciprocating file systems: an in vivo study.

Authors:  Reshma Parveen Shaik; Ram Sunil Chukka; Anila Bandlapally; Sayesh Vemuri; Nagesh Bolla; Ram Chowdary Basam; Sravanthi Tammineedi
Journal:  J Dent Anesth Pain Med       Date:  2022-07-26

8.  A Novel Technique for Identification of Wear Values at Different Lengths after Multiple Clinical Use of Different File Systems.

Authors:  Neslihan Yılmaz Çırakoğlu; Ersan Çiçek; Cevat Özarpa; Yağız Özbay; Olcay Özdemir
Journal:  Medicina (Kaunas)       Date:  2022-08-18       Impact factor: 2.948

9.  Cyclic Fatigue Resistance of Nickel-Titanium Rotary Instruments after Simulated Clinical Use.

Authors:  Hana R Ubaed; Diyar Kh Bakr
Journal:  Appl Bionics Biomech       Date:  2022-10-11       Impact factor: 1.664

10.  Safety and Effectiveness of Additional Apical Preparation using a Rotary Heat-treated Nickel-Titanium file with Larger Diameter and Minimum Taper in Retreatment of Curved Root Canals.

Authors:  Jader Camilo Pinto; Fernanda Ferrari Esteves Torres; Airton Oliveira Santos-Junior; Marco Antonio Hungaro Duarte; Juliane Maria Guerreiro-Tanomaru; Mario Tanomaru-Filho
Journal:  Eur J Dent       Date:  2021-02-23
  10 in total