Literature DB >> 16632283

Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments.

Maria Guiomar Azevedo Bahia1, Marta C C Melo, Vicente Tadeu Lopes Buono.   

Abstract

OBJECTIVE: The aim of this study was to assess the influence of cyclic deformation up to one half and three quarters of the fatigue life of NiTi rotary endodontic instruments on their behavior in torsion. STUDY
DESIGN: Thirty sets of 0.04 and 0.06 ProFile instruments in sizes #20, #25, and #30 were randomly divided into 3 groups: 1 contained 10 sets of new files, torsion tested to failure, while the other 2 groups, with 10 sets each, were first submitted to fatigue tests of up to one half and three fourths of their fatigue life, respectively, in geometrical conditions similar to those of the clinical practice and then torsion tested for rupture.
RESULTS: Statistical analysis of the values obtained for the torque to failure and maximum angular deflection, using the Student t test at the 95% confidence level, showed that the cyclic deformation of instruments of up to one half and three fourths of their fatigue life gives rise to a significant reduction in these parameters.
CONCLUSIONS: The simulated clinical use of ProFile instruments for shaping curved canals adversely affects their torsional properties.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16632283     DOI: 10.1016/j.tripleo.2005.04.019

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  8 in total

1.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

2.  Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments.

Authors:  Murilo Priori Alcalde; Marco Antonio Hungaro Duarte; Clovis Monteiro Bramante; Bruno Carvalho de Vasconselos; Mario Tanomaru-Filho; Juliane Maria Guerreiro-Tanomaru; Jader Camilo Pinto; Marcus Vinicius Reis Só; Rodrigo Ricci Vivan
Journal:  Clin Oral Investig       Date:  2017-12-09       Impact factor: 3.573

3.  The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments.

Authors:  Rafael Rodrigues Soares de Magalhães; Lígia Carolina Moreira Braga; Érika Sales Joviano Pereira; Isabella Faria da Cunha Peixoto; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
Journal:  J Appl Oral Sci       Date:  2016 Jul-Aug       Impact factor: 2.698

4.  Microscopic Features of Fractured Fragment of Nickel-Titanium Endodontic Instruments by Two Different Modes of Torsional Loading.

Authors:  Ibrahim H Abu-Tahun; Sang Won Kwak; Jung-Hong Ha; Hyeon-Cheol Kim
Journal:  Scanning       Date:  2018-02-21       Impact factor: 1.932

5.  Evaluation of dynamic and static torsional resistances of nickel-titanium rotary instruments.

Authors:  Ibrahim H Abu-Tahun; Jung-Hong Ha; Sang Won Kwak; Hyeon-Cheol Kim
Journal:  J Dent Sci       Date:  2018-02-01       Impact factor: 2.080

6.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27

7.  Comparative Evaluation of Physical Surface Changes and Incidence of Separation in Rotary Nickel-Titanium Instruments: An in Vitro SEM Study.

Authors:  Rudra Kaul; Riyaz Farooq; Vibhuti Kaul; Shafayat Ullah Khateeb; Aamir Rashid Purra; Roopali Mahajan
Journal:  Iran Endod J       Date:  2014-07-05

Review 8.  Present status and future directions: Canal shaping.

Authors:  Ana Arias; Ove A Peters
Journal:  Int Endod J       Date:  2022-02-16       Impact factor: 5.165

  8 in total