Literature DB >> 29181314

Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

Sha-Sha Yu1, Hui Song2, Xin Tang1,2,3,4.   

Abstract

AIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients.
METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability.
RESULTS: Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master.
CONCLUSION: Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

Entities:  

Keywords:  Ophtha Top topography; comparability; corneal parameters; repeatability

Year:  2017        PMID: 29181314      PMCID: PMC5686369          DOI: 10.18240/ijo.2017.11.11

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  32 in total

1.  Accuracy and precision of EyeSys and Orbscan systems on calibrated spherical test surfaces.

Authors:  Javier González Pérez; A Cerviño; M J Giraldez; M Parafita; E Yebra-Pimentel
Journal:  Eye Contact Lens       Date:  2004-04       Impact factor: 2.018

2.  Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and wavefront analysis.

Authors:  Mohammad-Reza Nilforoushan; Mark Speaker; Michael Marmor; Jodi Abramson; William Tullo; Dana Morschauser; Robert Latkany
Journal:  J Cataract Refract Surg       Date:  2008-04       Impact factor: 3.351

3.  Measurement error.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-09-21

4.  Comparison of automated and partial coherence keratometry and resulting choice of toric IOL.

Authors:  Jit B Ale Magar; Frank Cunningham; Garry Brian
Journal:  Optom Vis Sci       Date:  2013-04       Impact factor: 1.973

5.  Reproducibility of keratometric measurements decreases with time after blinking.

Authors:  B Erdélyi; B Csákány; J Németh
Journal:  Eur J Ophthalmol       Date:  2006 May-Jun       Impact factor: 2.597

6.  Comparison of keratometric and topographic cylinder and axis measurements on normal corneas with low astigmatism.

Authors:  C H Karabatsas; I Papaefthymiou; I M Aslanides; D Z Chatzoulis
Journal:  Eur J Ophthalmol       Date:  2005 Jan-Feb       Impact factor: 2.597

7.  Prevalence of corneal astigmatism before cataract surgery in Indian population.

Authors:  Pawan Prasher; Jasdeep Singh Sandhu
Journal:  Int Ophthalmol       Date:  2016-08-27       Impact factor: 2.031

8.  Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients.

Authors:  Maya Eibschitz-Tsimhoni; Omer Tsimhoni; Steven M Archer; Monte A Del Monte
Journal:  J AAPOS       Date:  2008-04       Impact factor: 1.220

9.  Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China.

Authors:  Ji-Guo Yu; Jie Zhong; Zhong-Ming Mei; Fang Zhao; Na Tao; Yi Xiang
Journal:  BMC Ophthalmol       Date:  2017-04-26       Impact factor: 2.209

10.  Prevalence of Corneal Astigmatism in Patients before Cataract Surgery in Northern China.

Authors:  Xiaoyong Yuan; Hui Song; Gang Peng; Xia Hua; Xin Tang
Journal:  J Ophthalmol       Date:  2014-06-03       Impact factor: 1.909

View more
  1 in total

1.  Comparison of keratometry data using handheld and table-mounted instruments in healthy adults.

Authors:  Hagar Olshaker; Ortal Buhbut; Asaf Achiron; Gad Dotan; Issac Levy; Raimo Tuuminen; Assaf Gershoni; Irit Bahar; Uri Elbaz
Journal:  Int Ophthalmol       Date:  2021-06-09       Impact factor: 2.031

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.