Literature DB >> 29044721

Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging.

Eric K Gibbons1,2, Shreyas S Vasanawala3, John M Pauly2, Adam B Kerr2.   

Abstract

PURPOSE: This work demonstrates a magnetization prepared diffusion-weighted single-shot fast spin echo (SS-FSE) pulse sequence for the application of body imaging to improve robustness to geometric distortion. This work also proposes a scan averaging technique that is superior to magnitude averaging and is not subject to artifacts due to object phase. THEORY AND METHODS: This single-shot sequence is robust against violation of the Carr-Purcell-Meiboom-Gill (CPMG) condition. This is achieved by dephasing the signal after diffusion weighting and tipping the MG component of the signal onto the longitudinal axis while the non-MG component is spoiled. The MG signal component is then excited and captured using a traditional SS-FSE sequence, although the echo needs to be recalled prior to each echo. Extended Parallel Imaging (ExtPI) averaging is used where coil sensitivities from the multiple acquisitions are concatenated into one large parallel imaging (PI) problem. The size of the PI problem is reduced by SVD-based coil compression which also provides background noise suppression. This sequence and reconstruction are evaluated in simulation, phantom scans, and in vivo abdominal clinical cases.
RESULTS: Simulations show that the sequence generates a stable signal throughout the echo train which leads to good image quality. This sequence is inherently low-SNR, but much of the SNR can be regained through scan averaging and the proposed ExtPI reconstruction. In vivo results show that the proposed method is able to provide diffusion encoded images while mitigating geometric distortion artifacts compared to EPI.
CONCLUSION: This work presents a diffusion-prepared SS-FSE sequence that is robust against the violation of the CPMG condition while providing diffusion contrast in clinical cases. Magn Reson Med 79:3032-3044, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  CPMG; SS-FSE; body imaging; diffusion weighting

Mesh:

Substances:

Year:  2017        PMID: 29044721      PMCID: PMC6312718          DOI: 10.1002/mrm.26971

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

2.  Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen.

Authors:  Jie Deng; Frank H Miller; Riad Salem; Reed A Omary; Andrew C Larson
Journal:  Invest Radiol       Date:  2006-10       Impact factor: 6.016

3.  Array compression for MRI with large coil arrays.

Authors:  Martin Buehrer; Klaas P Pruessmann; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

4.  Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver.

Authors:  Thomas C Kwee; Taro Takahara; Dow-Mu Koh; Rutger A J Nievelstein; Peter R Luijten
Journal:  J Magn Reson Imaging       Date:  2008-11       Impact factor: 4.813

Review 5.  Diffusion-weighted MR imaging of the liver.

Authors:  Bachir Taouli; Dow-Mu Koh
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

6.  Multishot diffusion-weighted SPLICE PROPELLER MRI of the abdomen.

Authors:  Jie Deng; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

7.  Realignment capability of the nCPMG sequence.

Authors:  P Le Roux; G McKinnon; Y-F Yen; B Fernandez
Journal:  J Magn Reson       Date:  2011-05-15       Impact factor: 2.229

8.  RARE imaging: a fast imaging method for clinical MR.

Authors:  J Hennig; A Nauerth; H Friedburg
Journal:  Magn Reson Med       Date:  1986-12       Impact factor: 4.668

9.  T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging.

Authors:  Jonathan I Tamir; Martin Uecker; Weitian Chen; Peng Lai; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2016-01-20       Impact factor: 4.668

10.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more
  5 in total

1.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

2.  Near-silent distortionless DWI using magnetization-prepared RUFIS.

Authors:  Jianmin Yuan; Yuxin Hu; Anne Menini; Christopher M Sandino; Jesse Sandberg; Vipul Sheth; Catherine J Moran; Marcus Alley; Michael Lustig; Brian Hargreaves; Shreyas Vasanawala
Journal:  Magn Reson Med       Date:  2019-11-29       Impact factor: 4.668

3.  Diffusion-prepared fast spin echo for artifact-free spinal cord imaging.

Authors:  Seung-Yi Lee; Briana P Meyer; Shekar N Kurpad; Matthew D Budde
Journal:  Magn Reson Med       Date:  2021-03-15       Impact factor: 3.737

4.  Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging.

Authors:  Qinwei Zhang; Petra J van Houdt; Doenja M J Lambregts; Baukelien van Triest; Marnix P M Kop; Bram F Coolen; Gustav J Strijkers; Uulke A van der Heide; Aart J Nederveen
Journal:  Eur Radiol Exp       Date:  2020-02-07

5.  Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

Authors:  Barbara Cervantes; Anh T Van; Dominik Weidlich; Hendrick Kooijman; Andreas Hock; Ernst J Rummeny; Alexandra Gersing; Jan S Kirschke; Dimitrios C Karampinos
Journal:  Magn Reson Med       Date:  2018-01-29       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.