OBJECTIVE: The objective of this study was to evaluate the feasibility of using multishot PROPELLER for diffusion-weighted imaging (DWI) of the abdomen. MATERIALS AND METHODS: Diffusion-weighted abdominal imaging was performed in 9 healthy volunteers and 3 patients using both single-shot DW-SE-EPI and multishot DW-PROPELLER (BLADE sequence). We compared ADC measurements in phantoms, liver and pancreatic tissues and performed qualitative comparisons of the diffusion-weighted images and ADC maps provided by these 2 techniques. RESULTS: DW-PROPELLER significantly improved image quality (P < 0.05) with reduced geometric distortion and artifact. The ADC values of phantoms and abdominal organs measured by DW-PROPELLER were generally greater than those measured by single-shot DW-SE-EPI. The ADC values measured by both DWI techniques were significantly different for liver tissues but not for pancreatic tissues (P < 0.05). Preliminary patient studies demonstrated clearly distinguished lesion areas from surrounding normal liver tissues in the DW-PROPELLER images. DW-PROPELLER offers the potential for high-resolution DWI of the abdomen. CONCLUSIONS: The multishot DW-PROPELLER sequence is a promising technique for DWI of abdominal organs. Future clinical studies will evaluate the use of DW-PROPELLER technique for abdominal oncologic imaging applications.
OBJECTIVE: The objective of this study was to evaluate the feasibility of using multishot PROPELLER for diffusion-weighted imaging (DWI) of the abdomen. MATERIALS AND METHODS: Diffusion-weighted abdominal imaging was performed in 9 healthy volunteers and 3 patients using both single-shot DW-SE-EPI and multishot DW-PROPELLER (BLADE sequence). We compared ADC measurements in phantoms, liver and pancreatic tissues and performed qualitative comparisons of the diffusion-weighted images and ADC maps provided by these 2 techniques. RESULTS: DW-PROPELLER significantly improved image quality (P < 0.05) with reduced geometric distortion and artifact. The ADC values of phantoms and abdominal organs measured by DW-PROPELLER were generally greater than those measured by single-shot DW-SE-EPI. The ADC values measured by both DWI techniques were significantly different for liver tissues but not for pancreatic tissues (P < 0.05). Preliminary patient studies demonstrated clearly distinguished lesion areas from surrounding normal liver tissues in the DW-PROPELLER images. DW-PROPELLER offers the potential for high-resolution DWI of the abdomen. CONCLUSIONS: The multishot DW-PROPELLER sequence is a promising technique for DWI of abdominal organs. Future clinical studies will evaluate the use of DW-PROPELLER technique for abdominal oncologic imaging applications.
Authors: Lan Lu; Bernadette Erokwu; Gregory Lee; Vikas Gulani; Mark A Griswold; Katherine M Dell; Chris A Flask Journal: Magn Reson Med Date: 2011-12-02 Impact factor: 4.668
Authors: Jong Hyuk Lee; Young Hun Choi; Jung Eun Cheon; So Mi Lee; Hyun Hae Cho; Su Mi Shin; Woo Sun Kim; In One Kim Journal: Pediatr Radiol Date: 2015-01-24
Authors: Sungheon Kim; Laurie Loevner; Harry Quon; Eric Sherman; Gregory Weinstein; Alex Kilger; Harish Poptani Journal: Clin Cancer Res Date: 2009-02-01 Impact factor: 12.531
Authors: Thomas C Kwee; Taro Takahara; Malou A Vermoolen; Marc B Bierings; Willem P Mali; Rutger A J Nievelstein Journal: Pediatr Radiol Date: 2010-07-30
Authors: C Fellner; C Menzel; F A Fellner; C Ginthoer; N Zorger; A Schreyer; E M Jung; S Feuerbach; T Finkenzeller Journal: AJNR Am J Neuroradiol Date: 2009-11-26 Impact factor: 3.825