Literature DB >> 17534913

Array compression for MRI with large coil arrays.

Martin Buehrer1, Klaas P Pruessmann, Peter Boesiger, Sebastian Kozerke.   

Abstract

Arrays with large numbers of independent coil elements are becoming increasingly available as they provide increased signal-to-noise ratios (SNRs) and improved parallel imaging performance. Processing of data from a large set of independent receive channels is, however, associated with an increased memory and computational load in reconstruction. This work addresses this problem by introducing coil array compression. The method allows one to reduce the number of datasets from independent channels by combining all or partial sets in the time domain prior to image reconstruction. It is demonstrated that array compression can be very effective depending on the size of the region of interest (ROI). Based on 2D in vivo data obtained with a 32-element phased-array coil in the heart, it is shown that the number of channels can be compressed to as few as four with only 0.3% SNR loss in an ROI encompassing the heart. With twofold parallel imaging, only a 2% loss in SNR occurred using the same compression factor.

Mesh:

Year:  2007        PMID: 17534913     DOI: 10.1002/mrm.21237

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  92 in total

1.  Coil compression for accelerated imaging with Cartesian sampling.

Authors:  Tao Zhang; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-04-09       Impact factor: 4.668

2.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

3.  Correlated spectroscopic imaging of calf muscle in three spatial dimensions using group sparse reconstruction of undersampled single and multichannel data.

Authors:  Neil E Wilson; Brian L Burns; Zohaib Iqbal; M Albert Thomas
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

4.  Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

Authors:  Daniel Neumann; Felix A Breuer; Michael Völker; Tobias Brandt; Mark A Griswold; Peter M Jakob; Martin Blaimer
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

5.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

6.  Simultaneous Time Interleaved MultiSlice (STIMS) for Rapid Susceptibility Weighted acquisition.

Authors:  Berkin Bilgic; Huihui Ye; Lawrence L Wald; Kawin Setsompop
Journal:  Neuroimage       Date:  2017-04-20       Impact factor: 6.556

7.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

Review 8.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

9.  Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI.

Authors:  Sajan Goud Lingala; Edward DiBella; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2014-07-29       Impact factor: 10.048

10.  Optimal decay rate constant estimates from phased array data utilizing joint Bayesian analysis.

Authors:  James D Quirk; Alexander L Sukstanskii; G Larry Bretthorst; Dmitriy A Yablonskiy
Journal:  J Magn Reson       Date:  2009-01-13       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.