Jonathan I Tamir1, Martin Uecker1, Weitian Chen2, Peng Lai2, Marcus T Alley3, Shreyas S Vasanawala3, Michael Lustig1. 1. Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California, USA. 2. Global Applied Science Laboratory, GE Healthcare, Menlo Park, California, USA. 3. Department of Radiology, Stanford University, Stanford, California, USA.
Abstract
PURPOSE: A new acquisition and reconstruction method called T2 Shuffling is presented for volumetric fast spin-echo (three-dimensional [3D] FSE) imaging. T2 Shuffling reduces blurring and recovers many images at multiple T2 contrasts from a single acquisition at clinically feasible scan times (6-7 min). THEORY AND METHODS: The parallel imaging forward model is modified to account for temporal signal relaxation during the echo train. Scan efficiency is improved by acquiring data during the transient signal decay and by increasing echo train lengths without loss in signal-to-noise ratio (SNR). By (1) randomly shuffling the phase encode view ordering, (2) constraining the temporal signal evolution to a low-dimensional subspace, and (3) promoting spatio-temporal correlations through locally low rank regularization, a time series of virtual echo time images is recovered from a single scan. A convex formulation is presented that is robust to partial voluming and radiofrequency field inhomogeneity. RESULTS: Retrospective undersampling and in vivo scans confirm the increase in sharpness afforded by T2 Shuffling. Multiple image contrasts are recovered and used to highlight pathology in pediatric patients. A proof-of-principle method is integrated into a clinical musculoskeletal imaging workflow. CONCLUSION: The proposed T2 Shuffling method improves the diagnostic utility of 3D FSE by reducing blurring and producing multiple image contrasts from a single scan. Magn Reson Med 77:180-195, 2017.
PURPOSE: A new acquisition and reconstruction method called T2 Shuffling is presented for volumetric fast spin-echo (three-dimensional [3D] FSE) imaging. T2 Shuffling reduces blurring and recovers many images at multiple T2 contrasts from a single acquisition at clinically feasible scan times (6-7 min). THEORY AND METHODS: The parallel imaging forward model is modified to account for temporal signal relaxation during the echo train. Scan efficiency is improved by acquiring data during the transient signal decay and by increasing echo train lengths without loss in signal-to-noise ratio (SNR). By (1) randomly shuffling the phase encode view ordering, (2) constraining the temporal signal evolution to a low-dimensional subspace, and (3) promoting spatio-temporal correlations through locally low rank regularization, a time series of virtual echo time images is recovered from a single scan. A convex formulation is presented that is robust to partial voluming and radiofrequency field inhomogeneity. RESULTS: Retrospective undersampling and in vivo scans confirm the increase in sharpness afforded by T2 Shuffling. Multiple image contrasts are recovered and used to highlight pathology in pediatric patients. A proof-of-principle method is integrated into a clinical musculoskeletal imaging workflow. CONCLUSION: The proposed T2 Shuffling method improves the diagnostic utility of 3D FSE by reducing blurring and producing multiple image contrasts from a single scan. Magn Reson Med 77:180-195, 2017.
Authors: Frederike H Petzschner; Irene P Ponce; Martin Blaimer; Peter M Jakob; Felix A Breuer Journal: Magn Reson Med Date: 2011-03-09 Impact factor: 4.668
Authors: Kyungsang Kim; Jong Chul Ye; William Worstell; Jinsong Ouyang; Yothin Rakvongthai; Georges El Fakhri; Quanzheng Li Journal: IEEE Trans Med Imaging Date: 2014-12-18 Impact factor: 10.048
Authors: Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig Journal: Magn Reson Med Date: 2014-03 Impact factor: 4.668
Authors: Dan Ma; Vikas Gulani; Nicole Seiberlich; Kecheng Liu; Jeffrey L Sunshine; Jeffrey L Duerk; Mark A Griswold Journal: Nature Date: 2013-03-14 Impact factor: 49.962
Authors: Jonathan I Tamir; Frank Ong; Suma Anand; Ekin Karasan; Ke Wang; Michael Lustig Journal: IEEE Signal Process Mag Date: 2020-01-17 Impact factor: 12.551
Authors: Sen Ma; Christopher T Nguyen; Fei Han; Nan Wang; Zixin Deng; Nader Binesh; Franklin G Moser; Anthony G Christodoulou; Debiao Li Journal: Magn Reson Med Date: 2019-11-25 Impact factor: 4.668
Authors: Fuyixue Wang; Zijing Dong; Timothy G Reese; Berkin Bilgic; Mary Katherine Manhard; Jingyuan Chen; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop Journal: Magn Reson Med Date: 2019-02-03 Impact factor: 4.668
Authors: Zhiyang Fu; Sagar Mandava; Mahesh B Keerthivasan; Zhitao Li; Kevin Johnson; Diego R Martin; Maria I Altbach; Ali Bilgin Journal: Magn Reson Imaging Date: 2020-09-01 Impact factor: 2.546