Literature DB >> 18429036

Multishot diffusion-weighted SPLICE PROPELLER MRI of the abdomen.

Jie Deng1, Reed A Omary, Andrew C Larson.   

Abstract

Multishot FSE (fast spin echo)-based diffusion-weighted (DW)-PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI offers the potential to reduce susceptibility artifacts associated with single-shot DW-EPI (echo-planar imaging) approaches. However, DW-PROPELLER in the abdomen is challenging due to the large field-of-view and respiratory motion during DW preparation. Incoherent signal phase due to motion will violate the Carr-Purcell-Meiboom-Gill (CPMG) conditions, leading to destructive interference between spin echo and stimulated echo signals and consequent signal cancellation. The SPLICE (split-echo acquisition of FSE signals) technique can mitigate non-CPMG artifacts in FSE-based sequences. For SPLICE, spin echo and stimulated echo are separated by using imbalanced readout gradients and extended acquisition window. Two signal families each with coherent phase properties are acquired at different intervals within the readout window. Separate reconstruction of these two signal families can avoid destructive phase interference. Phantom studies were performed to validate signal phase properties with different initial magnetization phases. This study evaluated the feasibility of combining SPLICE and PROPELLER for DW imaging of the abdomen. It is demonstrated that DW-SPLICE-PROPELLER can effectively mitigate non-CPMG artifacts and improve DW image quality and apparent diffusion coefficient (ADC) map homogeneity. (c) 2008 Wiley-Liss, Inc.

Mesh:

Year:  2008        PMID: 18429036     DOI: 10.1002/mrm.21525

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique.

Authors:  Jong Hyuk Lee; Young Hun Choi; Jung Eun Cheon; So Mi Lee; Hyun Hae Cho; Su Mi Shin; Woo Sun Kim; In One Kim
Journal:  Pediatr Radiol       Date:  2015-01-24

2.  Evaluation of the orbit using contrast-enhanced radial 3D fat-suppressed T1 weighted gradient echo (Radial-VIBE) sequence.

Authors:  Lev Bangiyev; Eytan Raz; Tobias K Block; Mari Hagiwara; Xin Wu; Eugene Yu; Girish M Fatterpekar
Journal:  Br J Radiol       Date:  2015-07-21       Impact factor: 3.039

3.  Quantitative multiparametric PROPELLER MRI of diethylnitrosamine-induced hepatocarcinogenesis in wister rat model.

Authors:  Jie Deng; Ning Jin; Xiaoming Yin; Guang-Yu Yang; Zhuoli Zhang; Reed A Omary; Andrew C Larson
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

4.  Decreased CSF-flow artefacts in T2 imaging of the cervical spine with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE).

Authors:  Andreas Ragoschke-Schumm; Peter Schmidt; Julia Schumm; Georg Reimann; Hans-Joachim Mentzel; Werner A Kaiser; Thomas E Mayer
Journal:  Neuroradiology       Date:  2010-04-13       Impact factor: 2.804

5.  Robust Self-Calibrating nCPMG Acquisition: Application to Body Diffusion-Weighted Imaging.

Authors:  Eric K Gibbons; Patrick Le Roux; Shreyas S Vasanawala; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2017-08-17       Impact factor: 10.048

6.  Body Diffusion Weighted Imaging Using Non-CPMG Fast Spin Echo.

Authors:  Eric K Gibbons; Patrick Le Roux; Shreyas S Vasanawala; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2016-10-27       Impact factor: 10.048

7.  Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging.

Authors:  Eric K Gibbons; Shreyas S Vasanawala; John M Pauly; Adam B Kerr
Journal:  Magn Reson Med       Date:  2017-10-17       Impact factor: 4.668

Review 8.  New methods in diffusion-weighted and diffusion tensor imaging.

Authors:  Roland Bammer; Samantha J Holdsworth; Wouter B Veldhuis; Stefan T Skare
Journal:  Magn Reson Imaging Clin N Am       Date:  2009-05       Impact factor: 2.266

9.  Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI.

Authors:  Hersh Chandarana; Kai T Block; Matthew J Winfeld; Shailee V Lala; Daniel Mazori; Emalyn Giuffrida; James S Babb; Sarah S Milla
Journal:  Eur Radiol       Date:  2013-09-25       Impact factor: 5.315

10.  Multishot targeted PROPELLER magnetic resonance imaging: description of the technique and initial applications.

Authors:  Jie Deng; Andrew C Larson
Journal:  Invest Radiol       Date:  2009-08       Impact factor: 6.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.