Literature DB >> 28911421

Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry.

Chui-Shiang Chang1, Tai Sheng Yeh2.   

Abstract

The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K), aspartame (ASP), cyclamate (CYC), dulcin (DUL), glycyrrhizic acid (GA), neotame (NEO), neohesperidin dihydrochalcone (NHDC), saccharin (SAC), sucralose (SCL), and stevioside (STV)] in various foods by liquid chromatography/tandem mass chromatography (LC-MS/MS) was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm) column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC-MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages) and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits). Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.
Copyright © 2014. Published by Elsevier B.V.

Entities:  

Keywords:  Beverages; Candied fruit; LC–MS/MS; Pickled peppers; Sweeteners

Year:  2014        PMID: 28911421      PMCID: PMC9354869          DOI: 10.1016/j.jfda.2014.01.024

Source DB:  PubMed          Journal:  J Food Drug Anal            Impact factor:   6.157


1. Introduction

Sweeteners are functional food additives that impart sweetness in food [1]. Sweeteners can be divided into two categories, natural and synthetic sweeteners. Synthetic sweeteners cannot be metabolized in the human body and provide no or little calories; therefore, they are also named nonnutritive sweeteners. Owing to the inherent low calories, nonnutritive sweeteners are beneficial for obesity, hypertension, diabetes, and dental caries control [2]. Demand for low-calorie foods other than soft drinks causes the increasing use of nonnutritive sweeteners; as a result, nonnutritive sweeteners have become ubiquitous in many foods. Increased consumption of nonnutritive sweeteners in recent years has become a global trend [3,4]. Occasionally, very high sweetener contents in food could happen. From the alert information of the Rapid Alert System for Food and Feed, the highest aspartame (ASP) concentration recorded in food was 6.98 g/kg [5] and the highest cyclamate (CYC) concentration recorded in food was 12.455 g/kg [6]. Because overconsumption of synthetic sweeteners can be harmful to health [7-9], regulatory monitoring of intense sweetener contents in food is necessary to protect consumers. For the risk characterization of nonnutritive sweeteners, the Joint Food and Agriculture Organization/World Health Organization Expert Committee on Food Additives (JECFA) had established an acceptable daily intake (ADI) of 15 mg/kg body weight for acesulfame potassium (ACS-K), 40 mg/kg body weight for ASP, 11 mg/kg body weight for sodium CYC, 5 mg/kg body weight for saccharin (SAC), 2 mg/kg body weight for neotame (NEO), 4 mg/kg body weight for steviol glycoside, and 15 mg/kg body weight for sucralose (SCL). The JECFA has given dulcin (DUL) an ADI of “not to be used”, which means that no DUL should be used in food. The JECFA did not establish an ADI for glycyrrhizic acid (GA), but the committee indicated that consumption of 100 mg/day would be unlikely to cause adverse effects in the majority of adults [10]. The Scientific Committee on Food in the European Union (EU) had established an ADI of 5 mg/kg body weight for neohesperidin dihydrochalcone (NHDC) [11]. Many countries around the world had different maximum usable dose regulations for synthetic sweeteners [11-13]. The regulatory status of the 10 sweeteners used in the present study in different countries is listed in Table 1. The EU had permitted seven artificial sweeteners—ACS-K, ASP, cyclamic acid and its salts, NHDC, NEO, SAC and its salts, and SCL—as food additives. In the recent Commission Regulation (EU) No. 1131/2011, the steviol glycosides level in food was regulated in the EU. The sweeteners ACS-K, advantame, alitame, ASP, CYC, NEO, SAC, steviol glycosides, SCL, and thaumatin were approved for use in Australia and New Zealand [14]. The US Food and Drug Administration (FDA) had only permitted five artificial sweeteners—ACS-K, ASP, NEO, SAC, and SCL—as food additives, and the use of CYC and NHDC were not permitted as food additives in the United States [15]. Even though purified steviol glycosides with rebaudioside A and STV as the principal components was considered GRAS (generally recognized as safe), crude extracts from Stevia plant were not permitted as food additives by the US FDA. There are five sweeteners—ACS-K, ASP, SAC, disodium glycyrrhizinate, and SCL—permitted for use in Japan [16]. Meanwhile, China has permitted ACS-K, alitame, ASP, CYC, GA, NEO, SAC, steviol glycosides, and SCL as food additives [17]. The sweeteners DUL and NHDC were not permitted in Taiwan, but ACS-K, ASP, CYC, GA, NEO, SAC, STV, and SCL were permitted as food additives.
Table 1

Regulatory status for the 10 sweeteners in the present study in different countries.

CompoundEUUS FDAJapanFSANZChinaTaiwan
ACS-KYesaYesYesYesYesYes
ASPYesYesYesYesYesYes
CYCYesNoNoYesYesYes
DULNobNoNoNoNoNo
GANoNoYesNoYesYes
NEOYesYesNoYesYesYes
NHDCYesNoNoNoNoNo
SACYesYesYesYesYesYes
STVYesNoNoYesYesYes
SCLYesYesYesYesYesYes

ACS-K = acesulfame potassium; ASP = aspartame; CYC = cyclamate; DUL = dulcin; EU = European Union; FSANZ = Food Standards Australia New Zealand; GA = glycyrrhizic acid; NEO = neotame; NHDC = neohesperidin dihydrochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside; US FDA = US Food and Drug Administration.

Yes: permitted food additive.

No: nonpermitted food additive.

There are several feasible analytical techniques for the analysis of sweeteners [18-24]. Many of the previous methods could analyze only one sweetener or simple sweetener mixtures. The synergistic use of sweeteners for cost reduction and taste quality improvement is often used, and the maximum permissible amount in food varies significantly [7,8,11,25,26]. An analytical method for the simultaneous determination of sweeteners in various food matrices is very important for food quality control and regulation enforcement. Wasik et al [21] developed a high-performance liquid chromatography–evaporative light scattering detection (HPLC–ELSD) method for detecting six authorized sweeteners (ACS-K, ASP, CYC, NHDC, SAC, and SCL) and three sweeteners not authorized by current EU legislation (NEO, alitame, and DUL) in carbonated and noncarbonated soft drinks, and canned or bottled fruits and yogurt. The limits of detection (LODs) were below 15 mg/kg, and the limits of quantification (LOQs) were below 30 mg/kg for all sweeteners except DUL. For DUL, the LOD was 30 mg/kg and the LOQ 50 mg/kg. Buchgraber and Wasik [23] conducted an interlaboratory study with the HPLC–ELSD method described by Wasik et al [21] for detecting nine sweeteners in carbonated and noncarbonated soft drinks and canned or bottled fruits. Because HPLC was not as sensitive as liquid chromatography-mass chromatography (LC–MS), Koyama et al [27] first developed an LC–MS method for the simultaneous determination of nine types of sweeteners (ACS-K, SCL, SAC, CYC, ASP, DUL, GA, STV, and rebaudioside A) in various foods. Koyama et al [27] did not use internal standards in their work and the mass detection was performed by selected ion monitoring (SIM). The LOQs of ACS-K, SAC, CYC, ASP, and STV were 1 mg/kg, and those of SCL, DUL, GA, and REB were 5 mg/kg. Owing to the ion suppression effect in the dried plum sample, the analyte solution was diluted five times in order to obtain a satisfactory recovery for ACS-K. Yang and Chen [28] developed an LC–MS method with warfarin sodium as the internal standard to analyze eight sweeteners (ASP, SAC, ACS-K, NEO, SCL, CYC, alitame, and STV) in beverages, candied fruits, and cakes. In the study by Yang and Chen [28], the LODs were below 0.10 mg/mL, whereas the LOQs were below 0.30 mg/mL. Zygler et al [29] developed an LC–MS method to analyze nine EU-regulated sweeteners in beverages, dairy, and fish products. The internal standard was N-(2-methylcyclohexyl)sulfamate. The LODs were below 0.25 μg/g and the LOQs were 2.5 μg/g. Most of the previous methods were based on SIM with a single quadruple mass spectrometer as the detector for chromatographic analysis. For confirmatory analysis in food safety regulation, the triple quadruple mass spectrometer could provide both qualitative and quantitative information with the multiple reaction monitoring (MRM) mode to increase the sensitivity and selectivity of the analysis. Therefore, liquid chromatography/tandem mass chromatography (LC–MS/MS) has become an increasingly popular tool for multiple sweeteners detection in foods and environment waters in recent years [25,30-34]. Scheurer et al [30] developed an LC–MS/MS method to analyze seven sweeteners in wastewater and surface water. Previously, the official sweetener method adopted by the Taiwan FDA was based on HPLC–DAD (diode array detection) to detect four sweeteners (ACS-K, SAC, DUL, and CYC) [24]. Only four sweeteners could be analyzed simultaneously in a single run, and the sensitivity and selectivity of the official method were also not good compared to those of the LC–MS/MS method. Therefore, a recommended method for multiple sweeteners analyzed by LC–MS/MS with the MRM mode was recommended by the Taiwan FDA [35]. With polarity switching, 10 sweeteners could be analyzed in a single run. The sweeteners ACS-K, CYC, GA, NHDC, SAC, and STV were detected in the negative ion mode, and ASP, SCL, DUL, and NEO were detected in the positive ion mode. In the present study, an LC–MS/MS method to detect 10 sweeteners in wines, beverages, sports drinks, pickled peppers, and candied fruits has been developed. Because no previous studies were done for the matrix effect by LC–MS/MS, the present study evaluated the matrix effect by comparing the slope of matrix-matched standard curve with that of the standard calibration curve [36]. Compared to the traditional HPLC method [18,21,23,24], the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run.

2. Materials and methods

2.1. Samples, reagents, and chemicals

Food samples were purchased from the local markets for food safety inspection by the Public Health Bureau, Pingtung County Government, Pingtung, China from January 2012 to May 2012. The samples included 11 nonalcoholic beverages (i.e., 1 lemon tea, 2 sports drink, 2 soft drinks, and 6 juices), 16 alcoholic beverages (i.e., 1 cocktail, 3 plum flavored wine, 8 grape wines, and 4 flavored beers), and 15 preserved fruits and vegetables (i.e., 1 pickled pepper, 11 preserved fruits, and 3 candies). ASP (99.9%), sodium CYC (99.9%), and sodium SAC (99.9%) were purchased from Supelco Co. (Bellefonte, PA, USA), whereas ACS-K (99%) and SCL (98%) were obtained from Fluka Chemie (Buchs, Switzerland). Stevioside (STV; 98.4%) and GA (98.9%) were purchased from ChromaDex Inc. (Irvine, CA, USA). NEO (99%) and NHDC (99.9%) were obtained from Sigma-Aldrich (Munich, Germany). DUL (99.8%) was obtained from Kanto Chemical Co., Inc. (Tokyo, Japan). All chemicals were of analytical grade. Methanol (HPLC-grade) was obtained from Biosolve (Valkenswaard, The Netherlands), whereas purified deionized water (R = 18 MΩ cm) was produced by a MilliQ unit (Millipore, Billerica, MA, USA). The chemical structures of all 10 sweeteners are shown in Fig. 1. Formic acid and acetonitrile were of HPLC grade and purchased from J.T. Baker Co., Ltd. (Philipsburg, NJ, USA). All other reagents were of analytical grade.
Fig. 1

Structures of the 10 sweeteners in the present study.

2.2. Instruments

The homogenizer (Retsch Knife Mill Grindomix GM200) was purchased from Thermo Fisher Scientific Co. (Haan, Germany) and the centrifuge (model Himac CF 16RX) was purchased from Hitachi Koki Co (Ibaraki, Japan). The ultrasonicator was purchased from Ney Dental Inc. (Yucaipa, CA, USA). The LC system was performed using Dionex Co. (Sunnyvale, CA, USA) with an autosampler and 30 μL sample loop. The LC-electrospray ionization (ESI)–MS/MS detection of sweeteners was achieved using an AB SCIEX QTRAP 4000 (Framingham, MA, USA) mass spectrometer. Data acquisition was conducted using the Analyst 6.1 software (Framingham, MA, USA). The sweeteners were separated on an analytical column, Luna Phenyl-Hexyl (5 μm, 4.6 × 150 mm) from Phenomenex (Torrance, CA, USA).

2.3. Preparation of standard solutions

The stock solution of GA was prepared by dissolving 0.05 g of the pure sweetener in 40 mL of deionized water at 80°C and diluting to 50 mL with deionized water. Stock solutions for other sweeteners were prepared by dissolving 0.05 g of pure sweeteners and making up the volume to 50 mL with deionized water. A series of working standard solutions were prepared with a concentration range of 0.05–10 μg/mL by diluting the stock solutions with an appropriate amount of deionized water. All stock solutions and working solutions were stored at 4°C and brought to room temperature prior to use.

2.4. Sample preparation

Because all the sweeteners in the present study have good solubility in water, the food samples are extracted by deionized water as in the official method of the Taiwan FDA for sweetener analysis. For the beverage samples, a 5-g sample was dissolved in 30 mL of deionized water and degassed in an ultrasonic bath for 10 minutes. After cooling down to room temperature, deionized water was added volumetrically to 50 mL. The sample solution was filtered through a 0.22-μm syringe filter prior to being injected into HPLC. For the solid food samples, a 5-g homogenized sample was dissolved in 30 mL of deionized water and ultrasonicated in an ultrasonic bath for 10 minutes, and followed by centrifugation at 2100g for 10 minutes. The supernatant was transferred into a 50-mL volumetric flask. The precipitate was washed with 10 mL of deionized water and repeated extraction. The supernatants were pooled into the same 50-mL volumetric flask, and deionized water was added volumetrically to 50 mL level. The sample solution was filtered through a 0.22-μm syringe filter prior to being injected into HPLC.

2.5. Chromatographic and mass spectrometric analysis

The sweeteners were separated on a 4.6 × 150 mm, 5 μm particle Phenomenex Luna Phenyl-Hexyl column. The mobile phase consisted of deionized water containing 10 mM ammonium acetate in channel A, and methanol containing 10 mM ammonium acetate in channel B. The column temperature was set at 35°C. The mobile phase flow rate was set at 1.0 mL/minute and the injection volume was 30 μL. The mobile phase gradient is listed in Table 2. Mass spectrum analysis was carried out using the ESI method with polarity switching on the AB SCIEX QTRAP 4000 triple quadrupole tandem mass spectrometer. The mass operation parameters were set as follows: curtain gas (CUR), 10 psi; collision gas (CAD), high; ionspray voltage (IS), 4500 V; temperature (TEM), 500°C; nebulizer gas (GS1), 50 psi; turbo gas 2 (GS2), 50 psi; dwell time, 50 milliseconds; scan type, MRM mode. The mass transition parameters for MRM are listed in Table 3.
Table 2

Gradient program of the mobile phase for HPLC separation of sweeteners in the present study.

Time (min)Flow rate (mL/min)Mobile phase

Aa (%)Bb (%)
01.08020
31.08020
61.05050
121.00100
151.00100
15.51.08020
181.08020

HPLC = high performance liquid chromatography.

A: 10 mM ammonium acetate in deionized water.

B: 10 mM ammonium acetate in methanol.

Table 3

MRM parameters for the sweeteners in the present study by LC–MS/MS.

CompoundPrecursorion (m/z)Production (m/z)Cone voltage (V)Collision energy (eV)
ACS-K16282a−34−18
16278−34−41
CYC17880a−74−35
17896−74−31
SAC18242a−61−48
182106−61−27
ASP293261a−40−14
293200−40−20
SCL395359a−103−18
397361−91−16
NHDC611303a−130−50
611125−130−70
STV641.2479a−183−61
641.2317−183−69
GA821113a−124−80
821351−124−63
DUL181108a5532
1811365522
NEO379172a6335
3793196327

ACS-K = acesulfame potassium; ASP = aspartame; CYC = cyclamate; DUL = dulcin; GA = glycyrrhizic acid; LC–MS/MS = liquid chromatography–tandem mass chromatography; MRM = multiple reaction monitoring; NEO = neotame; NHDC = neohesperidin dihydrochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside.

Ion for quantification.

2.6. Method validation and matrix effect evaluation

Method validation was done on a sweetener-free flavored beer and a sweetener-free dried guava as the representative matrix for beverage samples and solid food samples, respectively. For beverage samples, 5 g of the sweetener-free flavored beer in a 50-mL volumetric flask was spiked with the sweetener standard solution at the level of 0.5 μg/g, 1.0 μg/g, and 2.5 μg/g for the recovery test. The sample preparation procedure was the same as the beverage samples. For solid food samples, 5 g of the sweetener-free dried guava in a 50-mL volumetric flask was spiked with the sweetener standard solution at the level of 1.0 μg/g, 2.5 μg/g, and 5.0 μg/g for the recovery test. The sample preparation procedure was the same as the solid food samples. The matrix effect was evaluated according to the procedure described by Chang et al [36]. Two calibration curves were constructed to evaluate the matrix effect. The standard calibration curve was obtained by four sweetener concentrations of 0.1 μg/mL, 0.25 μg/mL, 0.5 μg/mL, and 1.0 μg/mL. The matrix-matched calibration curve was obtained by spiking four sweetener concentrations of 0.1 μg/mL, 0.25 μg/mL, 0.5 μg/mL, and 1.0 μg/mL into the sweetener-free dried guava samples.

3. Results and discussion

3.1. Mass spectrometric detection

Structures of the 10 sweeteners in the present study are shown in Fig. 1. The HPLC was connected to an ESI probe of the AB Sciex 4000Q triple quadruple mass spectrometer that was operated under the MRM mode. The product ion analysis of sweeteners was performed in the polarity-switching mode, which allowed the use of positive and negative ionization during the same run. The sweeteners ACS-K, SCL, SAC, CYC, ASP, GA, STV, and NHDC were detected in the negative ion mode. The [M-H]− ions were used as precursor ions for these eight sweeteners. DUL and NEO were detected in the positive ion mode. The [M+H]+ ions were the precursor ions for these two sweeteners. Two MRM transitions were selected to confirm the identity of each sweetener. The product ion with a stronger signal was selected as the ion for quantification, and the product ion with a weaker signal was selected as the ion for identification. The MRM transitions for each sweetener are shown in Table 3. The MRM chromatograms for 1.0 μg/mL sweeteners in the present study are shown in Fig. 2. In previous LC–MS studies by Koyama et al [27], Yang and Chen [28], and Zygler et al [26,29], only nine sweeteners could be detected under the SIM mode. The present study used the MRM mode to detect 10 sweeteners. Compared to the previous SIM mode, the MRM mode was more sensitive and had less matrix interference.
Fig. 2

Multiple reaction monitoring chromatograms for 10 sweeteners at the level of 1.0 μg/mL in the present study.

The LC–MS/MS method, recommended by the Taiwan FDA, suggested using the positive ion mode to detect ASP and SCL [35]. The MRM transitions for ASP were m/z 295 > 120 and m/z 295 > 180. The MRM transitions for SCL were m/z 414 > 199 and m/z 414 > 216. Under the positive ion mode, the sweeteners ASP and SCL could not be detected below the level of 0.1 μg/mL. Therefore, we used the negative ion mode to detect ASP and SCL in the present study. Yang and Chen [28] had selected warfarin sodium as the internal standard for ESI negative ion detection of sweeteners. In the present study, both positive and negative ionization modes were used for sweetener detection. Warfarin sodium was not suitable for the positive ion detection mode, so no internal standard was used in the present study. In previous study by Koyama et al [27], the mobile phase consisted of 5 mM dibutylammonium acetate (an ion pair reagent) as mobile phase A and acetonitrile/deionized water (8:2, v/v) as mobile phase B [27]. In the study of Yang and Chen [28], the mobile phase included formic acid and triethylamine as the buffer solution. The addition of 0.1% formic acid in the mobile phase did not only cause ACS-K, SAC, and CYC to have longer retention times, but also decreased their sensitivity. For the current work, triethylamine should not be used, because the triethylamine signal would persist for positive ion mode detection and the memory effect of triethylamine would interfere with the LC–MS analysis [37]. In the study of Chen et al [32], trifluoroacetic acid was added to the mobile phase. Similarly, trifluoroacetic acid could not be used if the negative ion work is planned on the same day, because it would induce memory effects and ion suppression, especially in the negative-ion mode [38]. Therefore, only 10 mM ammonium acetate was added to the mobile phase and the gradient program in Table 1 was used for chromatographic separation. The flow rate was set at 1.0 mL/minute and the injection volume was 30 μL. The analysis could be completed in 18 minutes for the 10 sweeteners. The MRM chromatograms of the 10 sweeteners in the present study are shown in Fig. 2.

3.2. Linearity, LOQ, and matrix effect

The calibration curves in the concentration range of 0.01–0.5 μg/L for the 10 sweeteners are shown in Table 4. In Table 4, the correlation coefficients for all 10 sweeteners were higher than 0.99, which revealed a good linearity in the concentration range for each sweetener. For the LOQ, a signal-to-noise ratio of 10 was evaluated. The LOQs of NHDC and SCL were 0.5 μg/g, and those of the other sweeteners were 0.1 μg/g, which were all less than the maximum regulatory limits.
Table 4

Linearity, limits of quantification, and matrix effects of the sweeteners in the present study.

Sweetenersy = ax + ba R 2 LOQ (μg/g)Matrix effect (%)
SACy = 491x + 14,6000.99120.11.2
CYCy = 1500x + 13,4000.99950.10.5
ASPy = 670x + 49500.99950.1−0.8
ACS-Ky = 6120x + 71,7000.99800.12.1
NHDCy = 72.6x + 22400.99560.5−12.5
STVy = 1140x + 3860.99920.11.3
GAy = 133x + 14700.99900.1−2.3
SCLy = 21.2x + 8740.99650.5−3.8
DULy = 3520x + 48,4000.99900.10.0
NEOy = 11,200x + 129,0000.99850.1−1.0

ACS-K = acesulfame potassium; ASP = aspartame; CYC = cyclamate; DUL = dulcin; GA = glycyrrhizic acid; LOQ = limit of quantification; NEO = neotame; NHDC = neohesperidin dihydrochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside.

Linear range: 0.01–0.5 μg/mL.

The matrix effects of the 10 sweeteners are listed in Table 4. For sweetener contents from 0.1 μg/g to 5 μg/g and from 1 μg/g to 100 μg/g, the calibration curves at the concentration range of 0.01 μg/mL to 0.5 μg/mL and 0.1 μg/mL to 10 μg/mL were selected to evaluate the matrix effects, respectively. In the dried guava, the matrix effect for NHDC is −12.5%. The other nine sweeteners have matrix effects of less than 5%.

3.3. Precision and recovery

The results of the precision and recovery test for the 10 sweeteners in beverage and solid food samples are listed in Tables 5 and 6, respectively. For beverage samples, the recoveries were 85–120% and the coefficients of variation (CVs) were 1.8–15.1%. For solid food samples, the recoveries were 75–118% and the CVs were 2.9–15.3%.
Table 5

Recoveries and CVs of the sweeteners in the flavored beer sample.

SweetenerSpiked level (μg/g)Recovery (%)CV (%)
SAC0.5987.1
1.01205.3
2.51185.9
CYC0.51125.1
1.01183.8
2.51092.5
ASP0.51105.6
1.01153.2
2.51141.8
ACS-K0.58512.5
1.01005.3
2.5974.1
NHDC0.5986.7
1.0955.4
2.51153.1
STV0.511613.5
1.01206.1
2.51075.2
GA0.510112.1
1.01198.9
2.51097.2
SCL0.59515.1
1.010710.6
2.511011.2
DUL0.51025.1
1.01163.8
2.51151.7
NEO0.51074.2
1.01203.1
2.51152.1

ACS-K = acesulfame potassium; ASP = aspartame; CV = coefficient of variation; CYC = cyclamate; DUL = dulcin; GA = glycyrrhizic acid; NEO = neotame; NHDC = neohesperidin dihydrochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside.

Table 6

Recoveries and CVs of the sweeteners in the dried guava sample.

SweetenerSpiked level (μg/g)Recovery (%)CV (%)
SAC1.01045.1
2.5914.5
5.01003.9
CYC1.0755.9
2.5834.7
5.0952.9
ASP1.0795.1
2.5964.2
5.01053.8
ACS-K1.011610.8
2.5828.4
5.01184.1
NHDC1.07515.3
2.58610.8
5.07711.8
STV1.07512.8
2.5908.9
5.01056.8
GA1.08213.1
2.58610.2
5.0909.1
SCL1.07813.1
2.510510.6
5.0868.7
DUL1.0798.1
2.5886.7
5.0893.9
NEO1.0806.9
2.5935.4
5.0963.8

ACS-K = acesulfame potassium; ASP = aspartame; CV = coefficient of variation; CYC = cyclamate; DUL = dulcin; GA = glycyrrhizic acid; NEO = neotame; NHDC = neohesperidin dihydrochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside.

3.4. Analytical results of sweeteners in foods on the market

Because the maximum usable dose for sweeteners could be as high as 1000 mg/kg in Taiwan, two calibration curves at the concentration range of 0.1–1.0 μg/mL and 1.0–10 μg/mL were recommended for real sample analysis. It is necessary to dilute the extracted sample solutions from 10 to 100 times to fit the concentration range of the above calibration curves. The detected sweetener contents of 27 beverage samples are shown in Table 7, and those of 15 solid food samples are shown in Table 8. Two wine samples with SAC and CYC were remanufactured red wine and not naturally fermented wines. Remanufactured wine is often made by blending edible alcohol with sweeteners and fruit juice. Therefore, the label for the sweetener in remanufactured wine should be regulated. Although NHDC was not permitted as a food additive in Taiwan, it was detected in two citrus lemonade extract samples. The maximum usable dose of NHDC in beverages was 30 ppm in the EU. The levels of NHDC found in the two citrus lemonade extract samples were lower than the EU regulatory level. The US FDA had regulated NHDC as a flavoring agent and not as a sweetener. Using the developed method, four solid food products were mislabeled in terms of the sweeteners used. The ingredient label for one pickled pepper was NEO, but SAC was detected instead. SAC was forbidden as a food additive for pickled peppers in Taiwan. One honey mongo was labeled SAC and CYC, but a blend of 71.5 μg/kg CYC, 11.4 μg/kg ACS-K, 25.4 μg/kg STV, and 18.5 μg/kg NEO were detected instead. One pickled kumquat and one dried plum were found to contain CYC, which was not specified in the ingredient label.
Table 7

Detected sweetener contents in 27 beverage samples.

VarietySweetener content (μg/g)Ingredient label
Plum wineN.D.
Sour (サワー)aN.D.
Red wineN.D.
Red wineN.D.
Plum grape wineSAC 7.2, CYC 126.5
Plum grape wineSAC 8.5, CYC 123
Grape wineN.D.
Red wineN.D.
Red wineN.D.
Sports drinkNEO 0.6NEO
Melon dewACS-K 41.4, SCL 8.3SCL
Melon dewN.D.
Sports drinkN.D.
Fruit juice with yukisio saltN.D.
Iced tea with lemon flavorN.D.
Mango flavored beerN.D.
Pineapple flavored beerN.D.
Passion fruit flavored beerN.D.
Peach flavored beerN.D.
Rose wineN.D.
Red yeast rice flavored grapewineN.D.
Red wineN.D.
Carbonated soft drinkACS-K 174, ASP 55.1ACS-K, ASP
Cola ZeroACS-K 175, ASP 98.4, SCL 59.8ACS-K, ASP, SCL
Peach flavored waterSCL 73.5SCL
Citrus lemonades extractNHDC 23.4
Citrus lemonades extractNHDC 19.1

ACS-K = acesulfame potassium; ASP = aspartame; CYC = cyclamate; DUL = dulcin; GA = glycyrrhizic acid; N.D. = not detected; NEO = neotame; NHDC = neohesperidin dihy-drochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside.

Sour (サワー) is a Japanese cocktail wine made by mixing distilled citrus wine and soda.

Table 8

Detected sweetener contents in 15 solid food samples

VarietySweetener content (μg/g)Ingredient label
Pickled pepperSAC 228NEO
Liquorice root marinated olivesNEO 6.9NEO, ACS-K, ASP, GA
ACS-K 9 3.8
ASP 87.1
GA 28.9
Hibiscus sabdariffa flowerSAC 106.5SAC, CYC
CYC 1365
Dried plumCYC 87SAC, CYC
Honey mangoCYC 71.5SAC, CYC
ACS-K 11.4
STV 25.4
NEO 18.5
Dried guavaN.D.a
Dried mangoN.D.
Dried guavaN.D.
Kumquat flavored candyN.D.
Fruit flavored lollipopN.D.
Ginseng flavored candyN.D.
Dried cranberriesN.D.
Pickled kumquatsCYC 621
Dried plumsCYC 859
RaisinsN.D.

ACS-K = acesulfame potassium; ASP = aspartame; CYC = cyclamate; DUL = dulcin; GA = glycyrrhizic acid; N.D. = not detected; NEO = neotame; NHDC = neohesperidin dihydrochalcone; SAC = saccharin; SCL = sucralose; STV = stevioside.

The present method was able to detect 10 popular and regulated sweeteners in foods. In the United States, thaumatin is a GRAS flavoring agent and also approved as a sweetener in the EU and Taiwan. The molecular weight of thaumatin is 2000 kDa, and it could not be detected directly by the current method without enzyme hydrolysis pretreatment. Therefore, thaumatin was not included in the current study.

4. Conclusion

A simple and rapid method for the simultaneous determination of 10 kinds of sweeteners (ACS-K, ASP, CYC, DUL, GA, NEO, NHDC, SAC, SCL, and STV) in various foods using LC–MS/MS was developed. In the official HPLC method for ACS-K, SAC, DUL, and CYC, the sample was directly subjected to HPLC analysis after the extraction by deionized water. Owing to interference from coeluents, the analysis was not confirmatory. Because CYC does not have a chromophore that absorbs UV or visible light, it needs to be derivatized prior to HPLC analysis. The developed LC-MS/MS method could analyze CYC without the derivatization step. The sample preparation step was quick and simple, and the recoveries and CVs were also very good with this method. Therefore, the method could be used routinely for regulation inspection.
  24 in total

Review 1.  Non-caloric sweeteners, sweetness modulators, and sweetener enhancers.

Authors:  Grant E DuBois; Indra Prakash
Journal:  Annu Rev Food Sci Technol       Date:  2012-01-03

2.  Determination of nine intense sweeteners in foodstuffs by high-performance liquid chromatography and evaporative light-scattering detection: interlaboratory study.

Authors:  Manuela Buchgraber; Andrzej Wasik
Journal:  J AOAC Int       Date:  2009 Jan-Feb       Impact factor: 1.913

3.  Application of dispersive solid-phase extraction and ultra-fast liquid chromatography-tandem quadrupole mass spectrometry in food additive residue analysis of red wine.

Authors:  Xiao-Hong Chen; Yong-Gang Zhao; Hao-Yu Shen; Mi-Cong Jin
Journal:  J Chromatogr A       Date:  2012-09-26       Impact factor: 4.759

4.  Determination of artificial sweeteners in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry.

Authors:  Edgar Y Ordóñez; José Benito Quintana; Rosario Rodil; Rafael Cela
Journal:  J Chromatogr A       Date:  2012-07-31       Impact factor: 4.759

5.  Low-calorie sweetener consumption is increasing in the United States.

Authors:  Allison C Sylvetsky; Jean A Welsh; Rebecca J Brown; Miriam B Vos
Journal:  Am J Clin Nutr       Date:  2012-08-01       Impact factor: 7.045

6.  Direct simultaneous determination of eight sweeteners in foods by capillary isotachophoresis.

Authors:  Michaela Herrmannová; Ludmila Krivánková; Martin Bartos; Karel Vytras
Journal:  J Sep Sci       Date:  2006-05       Impact factor: 3.645

7.  Impact of substituting added sugar in carbonated soft drinks by intense sweeteners in young adults in the Netherlands: example of a benefit-risk approach.

Authors:  Marieke A Hendriksen; Mariken J Tijhuis; Heidi P Fransen; Hans Verhagen; Jeljer Hoekstra
Journal:  Eur J Nutr       Date:  2010-04-29       Impact factor: 5.614

8.  Analysis and occurrence of seven artificial sweeteners in German waste water and surface water and in soil aquifer treatment (SAT).

Authors:  Marco Scheurer; Heinz-J Brauch; Frank T Lange
Journal:  Anal Bioanal Chem       Date:  2009-06-16       Impact factor: 4.142

9.  Estimated intake of intense sweeteners from non-alcoholic beverages in Denmark, 2005.

Authors:  T Leth; U Jensen; S Fagt; R Andersen
Journal:  Food Addit Contam Part A Chem Anal Control Expo Risk Assess       Date:  2008-06

10.  Determination of seven artificial sweeteners in diet food preparations by reverse-phase liquid chromatography with absorbance detection.

Authors:  J F Lawrence; C F Charbonneau
Journal:  J Assoc Off Anal Chem       Date:  1988 Sep-Oct
View more
  5 in total

1.  Development and validation of an LC-MS/MS method for the quantification of artificial sweeteners in human matrices.

Authors:  Eva Greibe; Magnus Leth-Møller; Sofie Stampe; Per Ovesen; Michael Pedersen; Elke Hoffmann-Lücke
Journal:  Biomed Chromatogr       Date:  2022-02-07       Impact factor: 1.911

2.  Development of a Sequential Injection Analysis System for the Determination of Saccharin.

Authors:  Budi Wibowotomo; Jong-Bang Eun; Jong Il Rhee
Journal:  Sensors (Basel)       Date:  2017-12-12       Impact factor: 3.576

3.  Development of ultrahigh-performance liquid chromatography/mass spectrometry and ultrahigh-performance supercritical fluid chromatography/mass spectrometry assays to determine the concentration of Bitrex™ and sodium saccharin in homemade facemask fit testing solutions.

Authors:  Julie M Herniman; G John Langley
Journal:  Rapid Commun Mass Spectrom       Date:  2020-08-30       Impact factor: 2.586

4.  Determining High-Intensity Sweeteners in White Spirits Using an Ultrahigh Performance Liquid Chromatograph with a Photo-Diode Array Detector and Charged Aerosol Detector.

Authors:  Kang Ma; Xiaojia Li; Yiwen Zhang; Fei Liu
Journal:  Molecules       Date:  2019-12-20       Impact factor: 4.411

5.  Simultaneous analysis of 23 illegal adulterated aphrodisiac chemical ingredients in health foods and Chinese traditional patent medicines by ultrahigh performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

Authors:  Xiao-Bing Wang; Jing Zheng; Jun-Jie Li; Hai-Ying Yu; Qi-Yan Li; Li-Hua Xu; Ming-Jie Liu; Rui-Qing Xian; Yang-En Sun; Bing-Jie Liu
Journal:  J Food Drug Anal       Date:  2018-03-14       Impact factor: 6.157

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.