Literature DB >> 16042292

[Analysis of nine kinds of sweeteners in foods by LC/MS].

Masamichi Koyama1, Kazuo Yoshida, Nobutake Uchibori, Ichirou Wada, Kazuyuki Akiyama, Tamami Sasaki.   

Abstract

A simple and rapid method for the simultaneous determination of nine kinds of sweeteners (acesulfame potassium, AK; sucralose, SUC; saccharin, SA; cyclamate, CYC; aspartame, APM; dulcin, DU; glycyrrhizic acid, GA; stevioside, STV; rebaudioside A, REB) in various foods by high-performance liquid chromatography-electrospray mass spectrometry (LC/ESI-MS) was developed. The LC separation was performed on a ZORBAX Eclipse XDB-C18 (2.1 mm x 150 mm) with a mobile phase of 5 mmol/L dibutylammonium acetate (DBAA) and acetonitrile-water (8: 2). Mass spectral acquisition was done in the negative ion mode by applying selected ion monitoring (SIM). The sweeteners were extracted from foods with 0.08 mol/L phosphate buffer (pH 7.0)- ethanol (1:1), and the extract was cleaned up on a Sep-pak Vac C18 cartridge after the addition of tetrabutylammonium bromide and phosphate buffer (pH 3.0). The recovery of the nine kinds of sweeteners from five kinds of foods fortified at the level 0.01 g/kg, 0.05 g/kg and 0.20 g/kg was 75.7-109.2%, and the between-day SD values were 0.5-10.9%. The quantification limits of AK, SA, CYC, APM and STV were 0.001 g/kg, and those of SUC, DU, GA and REB were 0.005 g/kg. A recovery test from each cleaned-up sample solution was necessary to detect ionization suppression.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16042292     DOI: 10.3358/shokueishi.46.72

Source DB:  PubMed          Journal:  Shokuhin Eiseigaku Zasshi        ISSN: 0015-6426            Impact factor:   0.464


  3 in total

1.  Determination of nine high-intensity sweeteners in various foods by high-performance liquid chromatography with mass spectrometric detection.

Authors:  Agata Zygler; Andrzej Wasik; Agata Kot-Wasik; Jacek Namieśnik
Journal:  Anal Bioanal Chem       Date:  2011-04-05       Impact factor: 4.142

2.  Determining High-Intensity Sweeteners in White Spirits Using an Ultrahigh Performance Liquid Chromatograph with a Photo-Diode Array Detector and Charged Aerosol Detector.

Authors:  Kang Ma; Xiaojia Li; Yiwen Zhang; Fei Liu
Journal:  Molecules       Date:  2019-12-20       Impact factor: 4.411

3.  Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry.

Authors:  Chui-Shiang Chang; Tai Sheng Yeh
Journal:  J Food Drug Anal       Date:  2014-02-20       Impact factor: 6.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.