Slice-selective RF pulses for in vivo B1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil.

Kawin Setsompop1, Vijayanand Alagappan, Borjan Gagoski, Thomas Witzel, Jonathan Polimeni, Andreas Potthast, Franz Hebrank, Ulrich Fontius, Franz Schmitt, Lawrence L Wald, Elfar Adalsteinsson.   

Abstract

Slice-selective RF waveforms that mitigate severe B1+ inhomogeneity at 7 Tesla using parallel excitation were designed and validated in a water phantom and human studies on six subjects using a 16-element degenerate stripline array coil driven with a butler matrix to utilize the eight most favorable birdcage modes. The parallel RF waveform design applied magnitude least-squares (MLS) criteria with an optimized k-space excitation trajectory to significantly improve profile uniformity compared to conventional least-squares (LS) designs. Parallel excitation RF pulses designed to excite a uniform in-plane flip angle (FA) with slice selection in the z-direction were demonstrated and compared with conventional sinc-pulse excitation and RF shimming. In all cases, the parallel RF excitation significantly mitigated the effects of inhomogeneous B1+ on the excitation FA. The optimized parallel RF pulses for human B1+ mitigation were only 67% longer than a conventional sinc-based excitation, but significantly outperformed RF shimming. For example the standard deviations (SDs) of the in-plane FA (averaged over six human studies) were 16.7% for conventional sinc excitation, 13.3% for RF shimming, and 7.6% for parallel excitation. This work demonstrates that excitations with parallel RF systems can provide slice selection with spatially uniform FAs at high field strengths with only a small pulse-duration penalty. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 19025908      PMCID: PMC2635025          DOI: 10.1002/mrm.21739

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

4.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

6.  Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels.

Authors:  Peter Ullmann; Sven Junge; Markus Wick; Frank Seifert; Wolfgang Ruhm; Jürgen Hennig
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

7.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

8.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

9.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

10.  Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels.

Authors:  K Setsompop; L L Wald; V Alagappan; B A Gagoski; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

View more
  66 in total

1.  Practical considerations for the design of sparse-spokes pulses.

Authors:  Marcin Jankiewicz; Huairen Zeng; Jason E Moore; Adam W Anderson; Malcolm J Avison; E Brian Welch; John C Gore
Journal:  J Magn Reson       Date:  2010-02-04       Impact factor: 2.229

2.  Broadband slab selection with B1+ mitigation at 7T via parallel spectral-spatial excitation.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; L L Wald; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

3.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

4.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

5.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

6.  Transmit B1-field correction at 7 T using actively tuned coupled inner elements.

Authors:  Hellmut Merkle; Joseph Murphy-Boesch; Peter van Gelderen; Shumin Wang; Tie-Qiang Li; Alan P Koretsky; Josef H Duyn
Journal:  Magn Reson Med       Date:  2011-03-24       Impact factor: 4.668

Review 7.  Magnetic Resonance Imaging technology-bridging the gap between noninvasive human imaging and optical microscopy.

Authors:  Jonathan R Polimeni; Lawrence L Wald
Journal:  Curr Opin Neurobiol       Date:  2018-05-11       Impact factor: 6.627

8.  Parallel excitation in the human brain at 9.4 T counteracting k-space errors with RF pulse design.

Authors:  Xiaoping Wu; J Thomas Vaughan; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

9.  Optically controlled on-coil amplifier with RF monitoring feedback.

Authors:  Natalia Gudino; Jacco A de Zwart; Qi Duan; Stephen J Dodd; Joe Murphy-Boesch; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

Review 10.  Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale.

Authors:  Thomas F Budinger; Mark D Bird; Lucio Frydman; Joanna R Long; Thomas H Mareci; William D Rooney; Bruce Rosen; John F Schenck; Victor D Schepkin; A Dean Sherry; Daniel K Sodickson; Charles S Springer; Keith R Thulborn; Kamil Uğurbil; Lawrence L Wald
Journal:  MAGMA       Date:  2016-05-18       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.