Literature DB >> 22890962

On-coil multiple channel transmit system based on class-D amplification and pre-amplification with current amplitude feedback.

Natalia Gudino1, Jeremiah A Heilman, Matthew J Riffe, Oliver Heid, Markus Vester, Mark A Griswold.   

Abstract

A complete high-efficiency transmit amplifier unit designed to be implemented in on-coil transmit arrays is presented. High power capability, low power dissipation, scalability, and cost minimization were some of the requirements imposed to the design. The system is composed of a current mode class-D amplifier output stage and a voltage mode class-D preamplification stage. The amplitude information of the radio frequency pulse was added through a customized step-down DC-DC converter with current amplitude feedback that connects to the current mode class-D stage. Benchtop measurements and imaging experiments were carried out to analyze system performance. Direct control of B1 was possible and its load sensitivity was reduced to less than 10% variation from unloaded to full loaded condition. When using the amplifiers in an array configuration, isolation above 20 dB was achieved between neighboring coils by the amplifier decoupling method. High output current operation of the transmitter was proved on the benchtop through output power measurements and in a 1.5T scanner through flip angle quantification. Finally, single and multiple channel excitations with the new hardware were demonstrated by receiving signal with the body coil of the scanner.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22890962      PMCID: PMC4848068          DOI: 10.1002/mrm.24462

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

2.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

3.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

4.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

5.  Eight-channel transmit/receive body MRI coil at 3T.

Authors:  P Vernickel; P Röschmann; C Findeklee; K-M Lüdeke; Ch Leussler; J Overweg; U Katscher; I Grässlin; K Schünemann
Journal:  Magn Reson Med       Date:  2007-08       Impact factor: 4.668

6.  Radiofrequency current source (RFCS) drive and decoupling technique for parallel transmit arrays using a high-power metal oxide semiconductor field-effect transistor (MOSFET).

Authors:  Wonje Lee; Eddy Boskamp; Thomas Grist; Krishna Kurpad
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

7.  Frequency-offset Cartesian feedback for MRI power amplifier linearization.

Authors:  Marta G Zanchi; Pascal Stang; Adam Kerr; John M Pauly; Greig C Scott
Journal:  IEEE Trans Med Imaging       Date:  2010-10-18       Impact factor: 10.048

8.  Ultra-low output impedance RF power amplifier for parallel excitation.

Authors:  Xu Chu; Xing Yang; Yunfeng Liu; Juan Sabate; Yudong Zhu
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

9.  Slice-selective RF pulses for in vivo B1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan Gagoski; Thomas Witzel; Jonathan Polimeni; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

10.  Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations.

Authors:  Riccardo Lattanzi; Daniel K Sodickson; Aaron K Grant; Yudong Zhu
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more
  10 in total

1.  Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating.

Authors:  N Gudino; M Sonmez; Z Yao; T Baig; S Nielles-Vallespin; A Z Faranesh; R J Lederman; M Martens; R S Balaban; M S Hansen; M A Griswold
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

2.  Sparse parallel transmission on randomly perturbed spiral k-space trajectory.

Authors:  Yong Pang; Xiaohua Jiang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-04

3.  Eight channel transmit array volume coil using on-coil radiofrequency current sources.

Authors:  Krishna N Kurpad; Eddy B Boskamp; Steven M Wright
Journal:  Quant Imaging Med Surg       Date:  2014-04

4.  High efficiency radiofrequency power amplifier module for parallel transmit arrays at 3 Tesla.

Authors:  Michael Twieg; Mark A Griswold
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

5.  Optically controlled on-coil amplifier with RF monitoring feedback.

Authors:  Natalia Gudino; Jacco A de Zwart; Qi Duan; Stephen J Dodd; Joe Murphy-Boesch; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

6.  Optically controlled switch-mode current-source amplifiers for on-coil implementation in high-field parallel transmission.

Authors:  Natalia Gudino; Qi Duan; Jacco A de Zwart; Joe Murphy-Boesch; Stephen J Dodd; Hellmut Merkle; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2015-08-10       Impact factor: 4.668

7.  Multi-turn transmit coil to increase b1 efficiency in current source amplification.

Authors:  N Gudino; M A Griswold
Journal:  Magn Reson Med       Date:  2013-02-11       Impact factor: 4.668

8.  An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers.

Authors:  Katherine Lynn Moody; Neal A Hollingsworth; Feng Zhao; Jon-Fredrik Nielsen; Douglas C Noll; Steven M Wright; Mary Preston McDougall
Journal:  J Magn Reson       Date:  2014-07-03       Impact factor: 2.229

9.  Eight-channel parallel transmit-receive system for 7 T MRI with optically controlled and monitored on-coil current-mode RF amplifiers.

Authors:  Natalia Gudino; Jacco A de Zwart; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2020-07-14       Impact factor: 3.737

Review 10.  Parallel transmission for ultrahigh-field imaging.

Authors:  Francesco Padormo; Arian Beqiri; Joseph V Hajnal; Shaihan J Malik
Journal:  NMR Biomed       Date:  2015-05-19       Impact factor: 4.044

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.