Literature DB >> 14705041

Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.

Jacco A de Zwart1, Patrick J Ledden, Peter van Gelderen, Jerzy Bodurka, Renxin Chu, Jeff H Duyn.   

Abstract

The performance of a 16-channel receive-only RF coil for brain imaging at 3.0 Tesla was investigated using a custom-built 16-channel receiver. Both the image signal-to-noise ratio (SNR) and the noise amplification (g-factor) in sensitivity-encoding (SENSE) parallel imaging applications were quantitatively evaluated. Furthermore, the performance was compared with that of hypothetical coils with one, two, four, and eight elements (n) by combining channels in software during image reconstruction. As expected, both the g-factor and SNR improved substantially with n. Compared to an equivalent (simulated) single-element coil, the 16-channel coil showed a 1.87-fold average increase in brain SNR. This was mainly due to an increase in SNR in the peripheral brain (an up to threefold SNR increase), whereas the SNR increase in the center of the brain was 4%. The incremental SNR gains became relatively small at large n, with a 9% gain observed when n was increased from 8 to 16. Compared to the (larger) product birdcage head coil, SNR increased by close to a factor of 2 in the center, and by up to a factor of 6 in the periphery of the brain. For low SENSE acceleration (rate-2), g-factors leveled off for n>4, and improved only slightly (1.4% averaged over brain) going from n=8 to n=16. Improvements in g for n>8 were larger for higher acceleration rates, with the improvement for rate-3 averaging 12.0%.

Mesh:

Year:  2004        PMID: 14705041     DOI: 10.1002/mrm.10678

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  70 in total

1.  Potential impact of a 32-channel receiving head coil technology on the results of a functional MRI paradigm.

Authors:  J Albrecht; M Burke; K Haegler; V Schöpf; A M Kleemann; M Paolini; M Wiesmann; J Linn
Journal:  Clin Neuroradiol       Date:  2010-09-21       Impact factor: 3.649

2.  Comparison of functional connectivity in default mode and sensorimotor networks at 3 and 7T.

Authors:  Joanne R Hale; Matthew J Brookes; Emma L Hall; Johanna M Zumer; Claire M Stevenson; Susan T Francis; Peter G Morris
Journal:  MAGMA       Date:  2010-07-13       Impact factor: 2.310

3.  Evaluation of image quality of a 32-channel versus a 12-channel head coil at 1.5T for MR imaging of the brain.

Authors:  P T Parikh; G S Sandhu; K A Blackham; M D Coffey; D Hsu; K Liu; J Jesberger; M Griswold; J L Sunshine
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-16       Impact factor: 3.825

4.  Physiological noise effects on the flip angle selection in BOLD fMRI.

Authors:  J Gonzalez-Castillo; V Roopchansingh; P A Bandettini; J Bodurka
Journal:  Neuroimage       Date:  2010-11-10       Impact factor: 6.556

5.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

Review 6.  Ultrafast inverse imaging techniques for fMRI.

Authors:  Fa-Hsuan Lin; Kevin W K Tsai; Ying-Hua Chu; Thomas Witzel; Aapo Nummenmaa; Tommi Raij; Jyrki Ahveninen; Wen-Jui Kuo; John W Belliveau
Journal:  Neuroimage       Date:  2012-01-21       Impact factor: 6.556

Review 7.  The future of ultra-high field MRI and fMRI for study of the human brain.

Authors:  Jeff H Duyn
Journal:  Neuroimage       Date:  2011-10-28       Impact factor: 6.556

8.  Advantages and pitfalls in 3T MR brain imaging: a pictorial review.

Authors:  Bernd L Schmitz; Andrik J Aschoff; Martin H K Hoffmann; Georg Grön
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

9.  Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA?

Authors:  A Le Bras; H Raoult; J-C Ferré; T Ronzière; J-Y Gauvrit
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.