Assessment of organ and effective dose when using region-of-interest attenuators in cone-beam CT and interventional fluoroscopy.

Zhenyu Xiong1,2, Sarath Vijayan1,2, Stephen Rudin1,2,3, Daniel R Bednarek1,2,3.   

Abstract

In some medical-imaging procedures using cone-beam CT (CBCT) and fluoroscopy, only the center of the field of view (FOV) may be needed to be visualized with optimal image quality. To reduce the dose to the patient while maintaining visualization of the entire FOV, a Cu attenuator with a circular aperture for the region of interest (ROI) is used. The potential organ and effective dose reductions of ROI imaging when applied to CBCT and interventional fluoroscopic procedures were determined using EGSnrc Monte Carlo code. The Monte Carlo model was first validated by comparing the surface dose distribution in a solid-water block phantom with measurement by Gafchromic film. The dependence of dose reduction on the ROI attenuator thickness, the opening size of the ROI, the axial beam position, and the location of the different organs for both neuro and thoracic imaging was evaluated. The results showed a reduction in most organ doses of 45% to 70% and in effective dose of 46% to 66% compared to the dose in a CBCT scan and in an interventional procedure without the ROI attenuator. This work provides evidence of a substantial reduction of organ and effective doses when using an ROI attenuator during CBCT and fluoroscopic procedures.

Entities:  

Keywords:  EGSnrc; Monte Carlo; cone-beam CT; dose reduction; interventional fluoroscopy procedure; region-of-interest imaging

Year:  2017        PMID: 28840169      PMCID: PMC5566265          DOI: 10.1117/1.JMI.4.3.031210

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  29 in total

1.  Using three-dimensional rotational angiography for sizing of covered stents.

Authors:  J C van den Berg; T Th C Overtoom; J C de Valois; F L Moll
Journal:  AJR Am J Roentgenol       Date:  2002-01       Impact factor: 3.959

2.  Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures.

Authors:  K Perisinakis; J Damilakis; N Theocharopoulos; E Manios; P Vardas; N Gourtsoyiannis
Journal:  Circulation       Date:  2001-07-03       Impact factor: 29.690

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms.

Authors:  U Missler; C Hundt; M Wiesmann; T Mayer; H Brückmann
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

5.  Simultaneous bilateral internal carotid artery 3D rotational angiography.

Authors:  Joon K Song; Yasunari Niimi; Jonathan L Brisman; Alejandro Berenstein
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

6.  Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.

Authors:  Albrecht Hochmuth; Uwe Spetzger; Martin Schumacher
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

7.  Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists.

Authors:  Gabriel Chodick; Nural Bekiroglu; Michael Hauptmann; Bruce H Alexander; D Michal Freedman; Michele Morin Doody; Li C Cheung; Steven L Simon; Robert M Weinstock; André Bouville; Alice J Sigurdson
Journal:  Am J Epidemiol       Date:  2008-07-29       Impact factor: 4.897

8.  Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy.

Authors:  George X Ding; Dennis M Duggan; Charles W Coffey
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

9.  The European Directive on health protection of individuals against the dangers of ionising radiation in relation to medical exposures (97/43/EURATOM).

Authors:  D Teunen
Journal:  J Radiol Prot       Date:  1998-06       Impact factor: 1.394

10.  Application of region-of-interest imaging techniques to neurointerventional radiology.

Authors:  S Rudin; L R Guterman; W E Granger; D R Bednarek; L N Hopkins
Journal:  Radiology       Date:  1996-06       Impact factor: 11.105

View more
  3 in total

1.  Calculation of Forward Scatter Dose Distribution at the skin entrance from the patient table for fluoroscopically guided interventions using a pencil beam convolution kernel.

Authors:  Sarath Vijayan; Zhenyu Xiong; Chao Guo; Jonathan Troville; Naveed Islam; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

2.  Investigation of organ dose variation with adult head size and pediatric age for neuro-interventional projections.

Authors:  Zhenyu Xiong; Sarath Vijayan; Chao Guo; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

3.  Assessment of Eye Lens Dose Reduction When Using Lateral Lead Shields on the Patient's Head during Neurointerventional Fluoroscopic Procedures and Cone-beam Computed Tomography (CBCT) Scans.

Authors:  Zhenyu Xiong; Stephen Rudin; Daniel R Bednarek
Journal:  Health Phys       Date:  2020-09       Impact factor: 2.922

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.