Literature DB >> 15569747

Simultaneous bilateral internal carotid artery 3D rotational angiography.

Joon K Song1, Yasunari Niimi, Jonathan L Brisman, Alejandro Berenstein.   

Abstract

We simultaneously injected both internal carotid arteries (ICAs) during 3D rotational digital subtraction angiography in a patient with a ruptured anterior communicating artery (Acom) aneurysm and vasospasm. Shaded surface display (SSD) images from this acquisition provided more anatomic detail than did SSD images created from individual ICA 3D rotational digital subtraction angriography. In the evaluation of complex Acom aneurysms, this technique can facilitate the choice of optimal working projections for safer aneurysm coiling.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15569747      PMCID: PMC8148748     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  6 in total

1.  Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment.

Authors:  R Anxionnat; S Bracard; X Ducrocq; Y Trousset; L Launay; E Kerrien; M Braun; R Vaillant; F Scomazzoni; A Lebedinsky; L Picard
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

2.  Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms.

Authors:  Takeshi Sugahara; Yukunori Korogi; Kouji Nakashima; Satoshi Hamatake; Shin Honda; Mutsumasa Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

3.  Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm.

Authors:  Toshi Abe; Masaru Hirohata; Norimitsu Tanaka; Yusuke Uchiyama; Kazuyuki Kojima; Kiminori Fujimoto; Alexander M Norbash; Naofumi Hayabuchi
Journal:  AJNR Am J Neuroradiol       Date:  2002-04       Impact factor: 3.825

4.  Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.

Authors:  Albrecht Hochmuth; Uwe Spetzger; Martin Schumacher
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

5.  Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: an in vitro study.

Authors:  Ulrike U Ernemann; Eckart Grönewäller; Frank B Duffner; Oezlem Guervit; Joerg Claassen; Martin D Skalej
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

6.  Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.

Authors:  Toshinori Hirai; Yukunori Korogi; Kenji Suginohara; Ken Ono; Tomohiro Nishi; Shozaburo Uemura; Masayuki Yamura; Yasuyuki Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

  6 in total
  5 in total

1.  Assessment of organ and effective dose when using region-of-interest attenuators in cone-beam CT and interventional fluoroscopy.

Authors:  Zhenyu Xiong; Sarath Vijayan; Stephen Rudin; Daniel R Bednarek
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-22

2.  Value of Flat-detector Computed Tomography Angiography with Intravenous Contrast Media Injection in the Evaluation and Treatment of Acutely Ruptured Aneurysms of the AcomA complex: A Single Center Experience in 15 Cases.

Authors:  Julie Rösch; Stefan Lang; Philipp Gölitz; Bernd Kallmünzer; Karl Rössler; Arnd Doerfler; Tobias Struffert
Journal:  Clin Neuroradiol       Date:  2017-05-05       Impact factor: 3.649

3.  Simultaneous Bilateral Vertebral Artery 3D Rotational Angiography. Technical Report of Two Cases.

Authors:  J F Reavey-Cantwell; S B Lewis; C Firment
Journal:  Interv Neuroradiol       Date:  2005-10-26       Impact factor: 1.610

4.  The Efficacy of Simultaneous Bilateral Internal Carotid Angiography during Coil Embolization for Anterior Communicating Artery Aneurysms.

Authors:  Soon Chan Kwon; Jun Bum Park; Shang Hun Shin; Hong Bo Sim; In Uk Lyo; Young Kim
Journal:  J Korean Neurosurg Soc       Date:  2011-05-31

5.  Effect of ROI filtering in 3D cone-beam rotational angiography on organ dose and effective dose in cerebral investigations.

Authors:  Fabian Göpfert; Ralph Schmidt; Jörg Wulff; Klemens Zink
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.